Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Jian Zhang 0074

dblp:07/314-74 · DBLP profile ↗
← Back
5ranked-venue papers
3as first author
0since 2021 · last 2012
—ORCID · conflict

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 3 · 1 first-authorSystems, architecture and hardware · 2 · 1 first-authorGraphics, computer vision, multimedia, augmented reality and games · 2 · 2 first-authorApplied, interdisciplinary, general and emerging computing · 2 · 2 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
2 papers
Robot manipulation · 83% Motion planning and robot control · 17%

Topics — the 2 heaviest of 4, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Robot manipulation › medical robotics › surgical robotics
cochlear implant insertion
0.222011
Algorithms and design considerations for robot assisted insertion of Perimodiolar Electrode Arrays · ICRA 2011
Model and parameter identification of friction during robotic insertion of cochlear-implant electrode arrays · ICRA 2009
Robotics › Robot manipulation › medical robotics
surgical robotics
0.222011
Algorithms and design considerations for robot assisted insertion of Perimodiolar Electrode Arrays · ICRA 2011
Model and parameter identification of friction during robotic insertion of cochlear-implant electrode arrays · ICRA 2009

Methods — techniques the papers use, named apart from their topics

kinematic simulation · 0.1statistical analysis · 0.1friction modeling · 0.1
YearPublicationVenuePosition
2012 Automated recognition of robotic manipulation failures in high-throughput biodosimetry tool
Youhua Chen, Jian Zhang 0074, Guy Garty, Nabil Simaan, Y. Lawrence Yao, David J. Brenner
Expert Syst. Appl.3
2011 Algorithms and design considerations for robot assisted insertion of Perimodiolar Electrode Arrays
abstract
This paper evaluates the potential for using robotic assistance for the insertion of commercial Perimodiolar Electrode Arrays (PEA's) that use a stylet and a pre-curved electrode body.We propose an algorithm for coordinated robotic insertion of the pre-curved electrode body and pulling of the stylet in order to provide partial control over the PEA shape. However, for robotic insertion to be a viable option for PEA's, an understanding of the statistical variability of their characteristics is essential. This paper investigates the kinematics of PEA's, their shape variability, and their expected performance during robotic insertion. An investigation of the required number of Degrees of Freedom (DoF) and the workspace is presented. A study of shape variability is carried out for characterizing shape repeatability across different insertion trials using the same electrode array. Also a study of shape variability is carried out between different electrode arrays. We simulate and evaluate the expected performance of three and four DoF robotic instruments for PEA insertion. The results support our proposed algorithm for coordinated insertion of the electrode array body and pulling of the stylet. They show that existing commerical perimodiolar arrays provide good shape repeatability. These results also point to the need for designing robotic insertion tools with at least four DoF. We believe that these results provide guidelines for future robotic instrument design for cochlear implant PEA's.
Jason Pile, Mei Yi Cheung, Jian Zhang 0074, Nabil Simaan
ICRA3
2009 Model and parameter identification of friction during robotic insertion of cochlear-implant electrode arrays
abstract
Robot-assisted cochlear implant surgery was proposed and proved to be efficient in reducing insertion forces on acrylic scala tympani models. During experiments, the authors discovered that the insertion force not only depends on the shape discrepancy between the scala tympani and the inserted electrode array, but also on the insertion speed. This paper presents a friction model that describes the whole insertion process and investigates the relationship between the insertion speed and the insertion force. Experimental and statistical results show the effectiveness of the model. Applying the friction model generates safety insertion force boundaries for future insertions and gives the optimal insertion speed. It also provides predictive force information for insertion speed feedback control law design which may be applied to robot-assisted cochlear implant surgeries.
Jian Zhang 0074, Samrat Bhattacharyya, Nabil Simaan
ICRA1
2008 Path Planning and Workspace Determination for Robot-Assisted Insertion of Steerable Electrode Arrays for Cochlear Implant Surgery
Jian Zhang 0074, Spiros Manolidis, J. Thomas Roland, Nabil Simaan
MICCAI (2)1
2006 A Pilot Study of Robot-Assisted Cochlear Implant Surgery Using Steerable Electrode Arrays
Jian Zhang 0074, Kai Xu 0005, Nabil Simaan, Spiros Manolidis
MICCAI (1)1