Demo Data from VLDB 2026 / reviewers in the wild / expert
Erwin J. Alles
dblp:118/2515
· DBLP profile ↗
2ranked-venue papers
0as first author
0since 2021 · last 2019
0000-0002-1658-4421ORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 2Systems, architecture and hardware · 2
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Interdisciplinary, comprehensive, and emerging computing
1 paper |
Medical and health informatics · 100% | |
| Artificial intelligence
1 paper |
Robot navigation and mapping · 100% |
Topics — the 2 heaviest of 2, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Medical and health informatics
surgical robotics |
0.4 | 1 | 2019 | Robotic Control of a Multi-Modal Rigid Endoscope Combining Optical Imaging with All-Optical Ultrasound · ICRA 2019 |
Robotics › Robot navigation and mapping
multimodal sensing |
0.1 | 1 | 2019 | Robotic Control of a Multi-Modal Rigid Endoscope Combining Optical Imaging with All-Optical Ultrasound · ICRA 2019 |
Methods — techniques the papers use, named apart from their topics
white light stereo camera · 0.8optical ultrasound · 0.8
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2019 | Robotic Control of a Multi-Modal Rigid Endoscope Combining Optical Imaging with All-Optical UltrasoundabstractFetoscopy is a technically challenging surgery, due to the dynamic environment and low diameter endoscopes often resulting in a limited field of view. In this paper, we report on the design and operation of a robotic multimodal endoscope with optical ultrasound and white light stereo camera. The manufacture and control of the endoscope is presented, along with large area (80 mm ×80 mm) surface visualisations of a placenta phantom using the optical ultrasound sensor. The repeatability of the surface visualisations was found to be 0. 446 ± 0.139 mm and 0. 267 ± 0.017 mm for a raster and spiral scan, respectively. George Dwyer, Richard J. Colchester, Erwin J. Alles, Efthymios Maneas, Sébastien Ourselin, Tom Vercauteren, Jan Deprest, Emmanuel B. Vander Poorten, Paolo De Coppi, Adrien E. Desjardins, Danail Stoyanov |
ICRA | 3 |
| 2015 | Fluidic actuation for intra-operative in situ imagingabstractA novel fluidic actuation system has been developed for in situ imaging of anatomic tissues. The actuator consists of a micromachined superelastic tool guide driven by a pair of pneumatic artificial muscles. Two additional working channels allow easy interchange of instruments or sensing equipment. This paper describes the design and construction of the actuation system. Experimental results are also reported indicating a bending repeatability of 0.1 degrees and an operational bandwidth exceeding 8Hz. To show-case the performance of the device, the actuator was loaded with an all-optical ultrasound imaging probe. First scanned images of human placental tissue surface using an all-optical ultrasound probe are presented. While a model has been developed to estimate the probe position in space as function of the input pressure, in future work, this model will be complemented with additional sensor measurements of the bending probe taking into account the hysteretic behaviour of both muscles and nitinol structure. Alain Devreker, Benoit Rosa, Adrien E. Desjardins, Erwin J. Alles, Luis C. García-Peraza-Herrera, Efthymios Maneas, Danail Stoyanov, Anna L. David, Tom Vercauteren, Jan Deprest, Sébastien Ourselin, Dominiek Reynaerts, Emmanuel B. Vander Poorten |
IROS | 4 |