VLDB 2026 Research / reviewers in the wild / expert
Cristina Di Poto
dblp:129/6038
· DBLP profile ↗
3ranked-venue papers
0as first author
0since 2021 · last 2016
—ORCID · none
Domains — the database's venue-derived domains; a paper can count in several
Applied, interdisciplinary, general and emerging computing · 3
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Interdisciplinary, comprehensive, and emerging computing
1 paper |
Bioinformatics and computational biology · 100% |
Topics — the 3 heaviest of 3, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Bioinformatics and computational biology › metabolomics
LC-MS data analysis |
0.2 | 1 | 2013 | Multi-profile Bayesian alignment model for LC-MS data analysis with integration of internal standards · Bioinform. 2013 |
Bioinformatics and computational biology
metabolomics |
0.2 | 1 | 2013 | Multi-profile Bayesian alignment model for LC-MS data analysis with integration of internal standards · Bioinform. 2013 |
Bioinformatics and computational biology › metabolomics
retention time alignment |
0.2 | 1 | 2013 | Multi-profile Bayesian alignment model for LC-MS data analysis with integration of internal standards · Bioinform. 2013 |
Methods — techniques the papers use, named apart from their topics
internal standard integration · 0.2bayesian modeling · 0.2
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2016 | Metabolomic data deconvolution using probabilistic purification modelsabstractLiquid (or gas) chromatography coupled with mass spectrometry (LC-MS or GC-MS) allows quantitative comparison of biomolecular abundance in biological samples to help with the discovery of candidate biomarkers for complex diseases such as cancer. A fundamental challenge in using quantitative analysis of biomolecules by LC-MS or GC-MS for cancer biomarker discovery is owing to the heterogeneous nature of human biospecimens. Various contaminations present in cancerous tissues or adjacent non-cancerous constituents confound the characterization of molecular expression profiles and thus hinder the discovery of reliable biomarkers. We previously applied probabilistic purification model on a relatively small sample-size metabolomic data. In this study, we further apply probabilistic purification models on larger sample-size and multi-group metabolomic datasets acquired by analysis of liver tissues using both LC-MS and GC-MS. We demonstrate the advantages of incorporating purification models in retrieving underlying sources and reduce noise in metabolomic data. Furthermore, we investigate the benefit of the proposed models in improving our ability to detect changes in the level of metabolites among liver tissue from multiple groups (tumor, liver cirrhosis, and normal). Minkun Wang, Cristina Di Poto, Alessia Ferrarini, Guoqiang Yu, Habtom W. Ressom |
BIBM | 2 |
| 2015 | SIMAT: GC-SIM-MS data analysis toolabstractBACKGROUND: Gas chromatography coupled with mass spectrometry (GC-MS) is one of the technologies widely used for qualitative and quantitative analysis of small molecules. In particular, GC coupled to single quadrupole MS can be utilized for targeted analysis by selected ion monitoring (SIM). However, to our knowledge, there are no software tools specifically designed for analysis of GC-SIM-MS data. In this paper, we introduce a new R/Bioconductor package called SIMAT for quantitative analysis of the levels of targeted analytes. SIMAT provides guidance in choosing fragments for a list of targets. This is accomplished through an optimization algorithm that has the capability to select the most appropriate fragments from overlapping chromatographic peaks based on a pre-specified library of background analytes. The tool also allows visualization of the total ion chromatograms (TIC) of runs and extracted ion chromatograms (EIC) of analytes of interest. Moreover, retention index (RI) calibration can be performed and raw GC-SIM-MS data can be imported in netCDF or NIST mass spectral library (MSL) formats. RESULTS: We evaluated the performance of SIMAT using two GC-SIM-MS datasets obtained by targeted analysis of: (1) plasma samples from 86 patients in a targeted metabolomic experiment; and (2) mixtures of internal standards spiked in plasma samples at varying concentrations in a method development study. Our results demonstrate that SIMAT offers alternative solutions to AMDIS and MetaboliteDetector to achieve accurate detection of targets and estimation of their relative intensities by analysis of GC-SIM-MS data. CONCLUSIONS: We introduce a new R package called SIMAT that allows the selection of the optimal set of fragments and retention time windows for target analytes in GC-SIM-MS based analysis. Also, various functions and algorithms are implemented in the tool to: (1) read and import raw data and spectral libraries; (2) perform GC-SIM-MS data preprocessing; and (3) plot and visualize EICs and TICs. Mohammad R. Nezami Ranjbar, Cristina Di Poto, Yue Joseph Wang, Habtom W. Ressom |
BMC Bioinform. | 2 |
| 2013 | Multi-profile Bayesian alignment model for LC-MS data analysis with integration of internal standardsabstractMOTIVATION: Liquid chromatography-mass spectrometry (LC-MS) has been widely used for profiling expression levels of biomolecules in various '-omic' studies including proteomics, metabolomics and glycomics. Appropriate LC-MS data preprocessing steps are needed to detect true differences between biological groups. Retention time (RT) alignment, which is required to ensure that ion intensity measurements among multiple LC-MS runs are comparable, is one of the most important yet challenging preprocessing steps. Current alignment approaches estimate RT variability using either single chromatograms or detected peaks, but do not simultaneously take into account the complementary information embedded in the entire LC-MS data. RESULTS: We propose a Bayesian alignment model for LC-MS data analysis. The alignment model provides estimates of the RT variability along with uncertainty measures. The model enables integration of multiple sources of information including internal standards and clustered chromatograms in a mathematically rigorous framework. We apply the model to LC-MS metabolomic, proteomic and glycomic data. The performance of the model is evaluated based on ground-truth data, by measuring correlation of variation, RT difference across runs and peak-matching performance. We demonstrate that Bayesian alignment model improves significantly the RT alignment performance through appropriate integration of relevant information. AVAILABILITY AND IMPLEMENTATION: MATLAB code, raw and preprocessed LC-MS data are available at http://omics.georgetown.edu/alignLCMS.html. CONTACT: [email protected]. SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online. Tsung-Heng Tsai, Mahlet G. Tadesse, Cristina Di Poto, Lewis K. Pannell, Yehia Mechref, Yue Joseph Wang, Habtom W. Ressom |
Bioinform. | 3 |