Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Manuel J. Freire

dblp:130/3515 · DBLP profile ↗
← Back
3ranked-venue papers
1as first author
0since 2021 · last 2015
0000-0002-4171-0995ORCID · verified

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 3 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Computer networks
1 paper
Physical-layer communications · 100%

Topics — the 2 heaviest of 2, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Physical-layer communications
metamaterials
0.112011
Bulk Metamaterials Made of Resonant Rings · Proc. IEEE 2011
Physical-layer communications
electromagnetic design
0.012011
Bulk Metamaterials Made of Resonant Rings · Proc. IEEE 2011
YearPublicationVenuePosition
2015 Analysis of the Noise Correlation in MRI Coil Arrays Loaded With Metamaterial Magnetoinductive Lenses
abstract
A numerical method is shown for calculating the noise correlation coefficient in arrays of magnetic resonance imaging (MRI) coils loaded with capacitively-loaded ring metamaterial lenses, and in the presence of a conducting half-space resembling a sample. This numerical method is validated by comparison with experimental results obtained in two different experimental procedures for double check: noise resistance measurements with a network analyzer and noise correlation measurements in an MRI system. It is found that, for practical array configurations such as overlapping coils or capacitively-decoupled coils, the noise correlation coefficient turns negative for coils loaded with metamaterial lenses. In particular, the analysis is carried out with metamaterial structures known as magnetoinductive lenses, which have been demonstrated in previous works to improve the signal-to-noise ratio of MRI coils. Results are also shown to demonstrate that negative noise correlations have as an effect the improvement of the g-factor in coil arrays for parallel MRI.
Jose M. Algarin, Felix Breuer, Volker C. Behr, Manuel J. Freire
IEEE Trans. Medical Imaging4
2013 A Broadside-Split-Ring Resonator-Based Coil for MRI at 7 T
abstract
A coil design termed as broadside-coupled loop (BCL) coil and based on the broadside-coupled split ring resonator (BC-SRR) is proposed as an alternative to a conventional loop design at 7T. The BCL coil has an inherent uniform current which assures the rotational symmetry of the radio-frequency field around the coil axis. A comparative analysis of the signal-to-noise ratio provided by BCL coils and conventional coils has been carried out by means of numerical simulations and experiments in a 7T whole body system.
Manuel J. Freire, Marcos A. Lopez, Florian Meise, Jose M. Algarin, Peter M. Jakob, Michael Bock, Ricardo Marqués
IEEE Trans. Medical Imaging1
2011 Bulk Metamaterials Made of Resonant Rings
abstract
In this brief review, we present the fundamentals of bulk resonant ring metamaterial (RRM) theory. Metamaterials made of resonant rings are discussed, and some basic design rules are provided. Homogenization (including spatial dispersion) of 3-D resonant ring latices is reviewed, with emphasis in isotropic designs. Edge effects in finite size metamaterial samples are discussed. Finally, possible applications and future trends are briefly reviewed.
Ricardo Marqués, Lukás Jelínek, Manuel J. Freire, Juan Domingo Baena, Mikhail Lapine
Proc. IEEE3