Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Xiong Wu 0003

dblp:134/5092-3 · DBLP profile ↗
← Back
1ranked-venue papers
0as first author
0since 2021 · last 2020
0000-0002-2878-1668ORCID · verified

Domains — the database's venue-derived domains; a paper can count in several

Security and privacy · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
1 paper
Energy systems and smart grids · 100%
Theoretical computer science
1 paper
Mathematical optimization · 100%

Topics — the 2 heaviest of 2, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Energy systems and smart grids › power system planning and operation
power system resilience
0.412020
Defense Strategy for Resilient Shipboard Power Systems Considering Sequential Attacks · IEEE Trans. Inf. Forensics Secur. 2020
Mathematical optimization › optimization under uncertainty
robust optimization
0.112020
Defense Strategy for Resilient Shipboard Power Systems Considering Sequential Attacks · IEEE Trans. Inf. Forensics Secur. 2020

Methods — techniques the papers use, named apart from their topics

tri-level robust optimization · 0.9nested column-constraint generation · 0.9
YearPublicationVenuePosition
2020 Defense Strategy for Resilient Shipboard Power Systems Considering Sequential Attacks
abstract
To increase the resilience of shipboard power systems, this paper presents an optimal defense strategy to protect critical lines against attacks. In the modeling, an attack is considered to destroy one critical bus, which may result in that all lines are connected to this bus will be out of service unless protection is enabled. Furthermore, after one true attack occurs, the network restoration is performed as soon as possible to pick up the critical loads and maintain system operation. To address the uncertain location of the attacks, a tri-level robust optimal defense strategy is set up to protect the critical lines under the worst attack. Moreover, a nested column-constraint generation method is employed to solve this model. A 60-bus shipboard power system is studied to demonstrate the effectiveness of the proposed model and the defense method.
Tao Ding 0001, Xiong Wu 0003, Boyu Qin, Yongheng Yang, Frede Blaabjerg
IEEE Trans. Inf. Forensics Secur.3