Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Efthymios Maneas

dblp:139/5687 · DBLP profile ↗
← Back
6ranked-venue papers
1as first author
0since 2021 · last 2020
0000-0001-5455-6854ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 3Applied, interdisciplinary, general and emerging computing · 3 · 1 first-authorSystems, architecture and hardware · 2Graphics, computer vision, multimedia, augmented reality and games · 2

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
2 papers
3D vision · 88% Robot navigation and mapping · 12%
Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%
Computer graphics and multimedia
1 paper
Computational photography and imaging · 100%

Topics — the 5 heaviest of 6, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Computer vision › 3D vision › structure from motion › generalized structure from motion
refractive structure from motion
0.412020
Refractive Two-View Reconstruction for Underwater 3D Vision · Int. J. Comput. Vis. 2020
Computer vision › 3D vision
structure from motion
0.412020
Refractive Two-View Reconstruction for Underwater 3D Vision · Int. J. Comput. Vis. 2020
Medical and health informatics
surgical robotics
0.412019
Robotic Control of a Multi-Modal Rigid Endoscope Combining Optical Imaging with All-Optical Ultrasound · ICRA 2019
Computational photography and imaging
underwater imaging
0.112020
Refractive Two-View Reconstruction for Underwater 3D Vision · Int. J. Comput. Vis. 2020
Robotics › Robot navigation and mapping
multimodal sensing
0.112019
Robotic Control of a Multi-Modal Rigid Endoscope Combining Optical Imaging with All-Optical Ultrasound · ICRA 2019

Methods — techniques the papers use, named apart from their topics

two-view reconstruction · 0.9refractive camera model · 0.9white light stereo camera · 0.8optical ultrasound · 0.8
YearPublicationVenuePosition
2020 Refractive Two-View Reconstruction for Underwater 3D Vision
abstract
Recovering 3D geometry from cameras in underwater applications involves the Refractive Structure-from-Motion problem where the non-linear distortion of light induced by a change of medium density invalidates the single viewpoint assumption. The pinhole-plus-distortion camera projection model suffers from a systematic geometric bias since refractive distortion depends on object distance. This leads to inaccurate camera pose and 3D shape estimation. To account for refraction, it is possible to use the axial camera model or to explicitly consider one or multiple parallel refractive interfaces whose orientations and positions with respect to the camera can be calibrated. Although it has been demonstrated that the refractive camera model is well-suited for underwater imaging, Refractive Structure-from-Motion remains particularly difficult to use in practice when considering the seldom studied case of a camera with a flat refractive interface. Our method applies to the case of underwater imaging systems whose entrance lens is in direct contact with the external medium. By adopting the refractive camera model, we provide a succinct derivation and expression for the refractive fundamental matrix and use this as the basis for a novel two-view reconstruction method for underwater imaging. For validation we use synthetic data to show the numerical properties of our method and we provide results on real data to demonstrate its practical application within laboratory settings and for medical applications in fluid-immersed endoscopy. We demonstrate our approach outperforms classic two-view Structure-from-Motion method relying on the pinhole-plus-distortion camera model.
François Chadebecq, Francisco Vasconcelos 0001, Rene M. Lacher, Efthymios Maneas, Adrien E. Desjardins, Sébastien Ourselin, Tom Vercauteren, Danail Stoyanov
Int. J. Comput. Vis.4
2019 Robotic Control of a Multi-Modal Rigid Endoscope Combining Optical Imaging with All-Optical Ultrasound
abstract
Fetoscopy is a technically challenging surgery, due to the dynamic environment and low diameter endoscopes often resulting in a limited field of view. In this paper, we report on the design and operation of a robotic multimodal endoscope with optical ultrasound and white light stereo camera. The manufacture and control of the endoscope is presented, along with large area (80 mm ×80 mm) surface visualisations of a placenta phantom using the optical ultrasound sensor. The repeatability of the surface visualisations was found to be 0. 446 ± 0.139 mm and 0. 267 ± 0.017 mm for a raster and spiral scan, respectively.
George Dwyer, Richard J. Colchester, Erwin J. Alles, Efthymios Maneas, Sébastien Ourselin, Tom Vercauteren, Jan Deprest, Emmanuel B. Vander Poorten, Paolo De Coppi, Adrien E. Desjardins, Danail Stoyanov
ICRA4
2015 Fluidic actuation for intra-operative in situ imaging
abstract
A novel fluidic actuation system has been developed for in situ imaging of anatomic tissues. The actuator consists of a micromachined superelastic tool guide driven by a pair of pneumatic artificial muscles. Two additional working channels allow easy interchange of instruments or sensing equipment. This paper describes the design and construction of the actuation system. Experimental results are also reported indicating a bending repeatability of 0.1 degrees and an operational bandwidth exceeding 8Hz. To show-case the performance of the device, the actuator was loaded with an all-optical ultrasound imaging probe. First scanned images of human placental tissue surface using an all-optical ultrasound probe are presented. While a model has been developed to estimate the probe position in space as function of the input pressure, in future work, this model will be complemented with additional sensor measurements of the bending probe taking into account the hysteretic behaviour of both muscles and nitinol structure.
Alain Devreker, Benoit Rosa, Adrien E. Desjardins, Erwin J. Alles, Luis C. García-Peraza-Herrera, Efthymios Maneas, Danail Stoyanov, Anna L. David, Tom Vercauteren, Jan Deprest, Sébastien Ourselin, Dominiek Reynaerts, Emmanuel B. Vander Poorten
IROS6
2015 A Registration Approach to Endoscopic Laser Speckle Contrast Imaging for Intrauterine Visualisation of Placental Vessels
Gustavo Sato dos Santos, Efthymios Maneas, Daniil I. Nikitichev, Anamaria Barburas, Anna L. David, Jan Deprest, Adrien E. Desjardins, Tom Vercauteren, Sébastien Ourselin
MICCAI (1)2
2015 Interventional Photoacoustic Imaging of the Human Placenta with Ultrasonic Tracking for Minimally Invasive Fetal Surgeries
Wenfeng Xia 0001, Efthymios Maneas, Daniil I. Nikitichev, Charles A. Mosse, Gustavo Sato dos Santos, Tom Vercauteren, Anna L. David, Jan Deprest, Sébastien Ourselin, Paul C. Beard, Adrien E. Desjardins
MICCAI (1)2
2013 Developing a simulator for multispectral optoacoustic tomography
abstract
The aim of this study was the development of a simulator for Multispectral Optoacoustic Tomography (MSOT). The modelling pathway of the simulator was separated into the optical, the acoustic and the reconstruction part in generating finally a photoacoustic image. In this paper, the presented simulation geometry was based on a recently developed MSOT imaging system, but it can be easily modified to other imaging geometries. Through comparison between experimental and simulated data, a validation of the model as well as its limitations, perspectives and modifications are presented.
Efthymios Maneas, Stratis Tzoumas, Vasilis Ntziachristos, George M. Spyrou
BIBE1