Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data.

Brent D. Mittelstadt 0001

dblp:139/6836 · DBLP profile ↗
← Back
2ranked-venue papers
0as first author
0since 2021 · last 1994
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 1Systems, architecture and hardware · 1Applied, interdisciplinary, general and emerging computing · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
2 papers
Motion planning and robot control · 59% Robot manipulation · 41%
Interdisciplinary, comprehensive, and emerging computing
2 papers
Medical and health informatics · 100%

Topics — the 7 heaviest of 7, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics
surgical robotics
0.021994
An image-directed robotic system for precise orthopaedic surgery · IEEE Trans. Robotics Autom. 1994
Force sensing and control for a surgical robot · ICRA 1992
Medical and health informatics
orthopedic surgery
0.011994
An image-directed robotic system for precise orthopaedic surgery · IEEE Trans. Robotics Autom. 1994
Robotics › Motion planning and robot control › robot control
force control
0.011992
Force sensing and control for a surgical robot · ICRA 1992
Robotics › Robot manipulation
force sensing
0.011992
Force sensing and control for a surgical robot · ICRA 1992
Robotics › Motion planning and robot control
robot control
0.011992
Force sensing and control for a surgical robot · ICRA 1992
Robotics › Robot manipulation › industrial robot
machining robot
0.011994
An image-directed robotic system for precise orthopaedic surgery · IEEE Trans. Robotics Autom. 1994
Medical and health informatics › surgical robotics
robot-assisted surgery
0.011992
Force sensing and control for a surgical robot · ICRA 1992

Methods — techniques the papers use, named apart from their topics

CT-based presurgical planning · 0.0guarded moves · 0.0force feedback control · 0.0ball-in-cone strategy · 0.0
YearPublicationVenuePosition
1994 An image-directed robotic system for precise orthopaedic surgery
abstract
The authors have developed an image-directed robotic system to augment the performance of human surgeons in precise bone machining procedures in orthopaedic surgery, initially targeted at cementless total hip replacement surgery. The total system consists of an interactive CT-based presurgical planning component and a surgical system consisting of a robot, redundant motion monitoring, and man-machine interface components. In vitro experiments conducted with this system have demonstrated an order-of-magnitude improvement in implant fit and placement accuracy, compared to standard manual preparation techniques. The first generation system described in this paper was used in a successful veterinary clinical trial on 26 dogs needing hip replacement surgery. It was the basis for subsequent development of a second-generation system that is now in human clinical trials.>
Russell H. Taylor, Brent D. Mittelstadt 0001, Howard A. Paul, William Hanson, Peter Kazanzides, Joel F. Zuhars, Bill Williamson, Bela L. Musits, Edward Glassman, William L. Bargar
IEEE Trans. Robotics Autom.2
1992 Force sensing and control for a surgical robot
abstract
The authors describe the use of force feedback in a surgical robot system (ROBODOC). The application initially being addressed is total hip replacement (THR) surgery, where the robot must prepare a cavity in the femur for an artificial implant. In this system, force feedback is used to provide safety, tactile search capabilities, and an improved man-machine interface. Output of the force sensor is monitored by a safety processor, which initiates corrective action if any of several application-defined thresholds are exceeded. The robot is able to locate objects using guarded moves and force control (ball-in-cone strategy). In addition, the force control algorithm provides an intuitive man-machine interface which allows the surgeon to guide the robot by leading its tool to the desired location. An application of force control currently under development is described, where the force feedback is used to modify the cutter feed rate (force controlled velocity).>
Peter Kazanzides, Joel F. Zuhars, Brent D. Mittelstadt 0001, Russell H. Taylor
ICRA3