Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Frédéric Bernardin

dblp:147/9517 · DBLP profile ↗
← Back
4ranked-venue papers
0as first author
2since 2021 · last 2026
0000-0002-1248-153XORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 4 · 2 since 2021Graphics, computer vision, multimedia, augmented reality and games · 2 · 1 since 2021

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Computer graphics and multimedia
2 papers
Computational photography and imaging · 95% Multimedia analysis and retrieval · 5%

Topics — the 5 heaviest of 5, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Computational photography and imaging
camera calibration
1.022022
Leveraging Blur Information for Plenoptic Camera Calibration · Int. J. Comput. Vis. 2022
Blur Aware Calibration of Multi-Focus Plenoptic Camera · CVPR 2020
Computational photography and imaging › camera calibration
light field camera calibration
1.022022
Leveraging Blur Information for Plenoptic Camera Calibration · Int. J. Comput. Vis. 2022
Blur Aware Calibration of Multi-Focus Plenoptic Camera · CVPR 2020
Computational photography and imaging › depth of field
defocus blur
0.212022
Leveraging Blur Information for Plenoptic Camera Calibration · Int. J. Comput. Vis. 2022
Computational photography and imaging
light field imaging
0.212022
Leveraging Blur Information for Plenoptic Camera Calibration · Int. J. Comput. Vis. 2022
Multimedia analysis and retrieval › image analysis
image blur analysis
0.112020
Blur Aware Calibration of Multi-Focus Plenoptic Camera · CVPR 2020

Methods — techniques the papers use, named apart from their topics

point spread function modeling · 0.6optimization · 0.6blur-aware feature · 0.6cost function optimization · 0.4blur aware plenoptic feature · 0.4
YearPublicationVenuePosition
2026 Stylistic-STORM (ST-STORM): Self-supervised Spectral Disentanglement Using Adversarial Learning and JEPA for Weather Analysis
Hamed Ouattara, Pierre Duthon, Pascal Houssam Salmane, Frédéric Bernardin, Omar Ait-Aider
ICPR (6)4
2022 Leveraging Blur Information for Plenoptic Camera Calibration
abstract
Abstract This paper presents a novel calibration algorithm for plenoptic cameras, especially the multi-focus configuration, where several types of micro-lenses are used, using raw images only. Current calibration methods rely on simplified projection models, use features from reconstructed images, or require separated calibrations for each type of micro-lens. In the multi-focus configuration, the same part of a scene will demonstrate different amounts of blur according to the micro-lens focal length. Usually, only micro-images with the smallest amount of blur are used. In order to exploit all available data, we propose to explicitly model the defocus blur in a new camera model with the help of our newly introduced Blur Aware Plenoptic (BAP) feature. First, it is used in a pre-calibration step that retrieves initial camera parameters, and second, to express a new cost function to be minimized in our single optimization process. Third, it is exploited to calibrate the relative blur between micro-images. It links the geometric blur, i.e., the blur circle, to the physical blur, i.e., the point spread function. Finally, we use the resulting blur profile to characterize the camera’s depth of field. Quantitative evaluations in controlled environment on real-world data demonstrate the effectiveness of our calibrations.
Mathieu Labussière, Céline Teulière, Frédéric Bernardin, Omar Ait-Aider
Int. J. Comput. Vis.3
2020 Blur Aware Calibration of Multi-Focus Plenoptic Camera
abstract
This paper presents a novel calibration algorithm for Multi-Focus Plenoptic Cameras (MFPCs) using raw images only. The design of such cameras is usually complex and relies on precise placement of optic elements. Several calibration procedures have been proposed to retrieve the camera parameters but relying on simplified models, reconstructed images to extract features, or multiple calibrations when several types of micro-lens are used. Considering blur information, we propose a new Blur Aware Plenoptic (BAP) feature. It is first exploited in a pre-calibration step that retrieves initial camera parameters, and secondly to express a new cost function for our single optimization process. The effectiveness of our calibration method is validated by quantitative and qualitative experiments.
Mathieu Labussière, Céline Teulière, Frédéric Bernardin, Omar Ait-Aider
CVPR3
2018 Benchmark for the robustness of image features in rainy conditions
Pierre Duthon, Frédéric Bernardin, Frédéric Chausse, Michèle Colomb
Mach. Vis. Appl.2