VLDB 2026 Research / reviewers in the wild / expert
Kris Thielemans
dblp:16/633
· DBLP profile ↗
14ranked-venue papers
0as first author
4since 2021 · last 2025
0000-0002-5514-199XORCID · verified
Domains — the database's venue-derived domains; a paper can count in several
Applied, interdisciplinary, general and emerging computing · 14 · 4 since 2021Graphics, computer vision, multimedia, augmented reality and games · 3 · 2 since 2021
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2025 | DIGS: Dynamic CBCT Reconstruction Using Deformation-Informed 4D Gaussian Splatting and a Low-Rank Free-Form Deformation Model
Yuliang Huang, Imraj RD Singh, Thomas Joyce, Kris Thielemans, Jamie McClelland |
MICCAI (4) | 4 |
| 2024 | Resolving Variable Respiratory Motion From Unsorted 4D Computed Tomography
Yuliang Huang, Björn Eiben, Kris Thielemans, Jamie McClelland |
MICCAI (1) | 3 |
| 2023 | An Investigation of Stochastic Variance Reduction Algorithms for Relative Difference Penalized 3D PET Image ReconstructionabstractPenalised PET image reconstruction algorithms are often accelerated during early iterations with the use of subsets. However, these methods may exhibit limit cycle behaviour at later iterations due to variations between subsets. Desirable converged images can be achieved for a subclass of these algorithms via the implementation of a relaxed step size sequence, but the heuristic selection of parameters will impact the quality of the image sequence and algorithm convergence rates. In this work, we demonstrate the adaption and application of a class of stochastic variance reduction gradient algorithms for PET image reconstruction using the relative difference penalty and numerically compare convergence performance to BSREM. The two investigated algorithms are: SAGA and SVRG. These algorithms require the retention in memory of recently computed subset gradients, which are utilised in subsequent updates. We present several numerical studies based on Monte Carlo simulated data and a patient data set for fully 3D PET acquisitions. The impact of the number of subsets, different preconditioners and step size methods on the convergence of regions of interest values within the reconstructed images is explored. We observe that when using constant preconditioning, SAGA and SVRG demonstrate reduced variations in voxel values between subsequent updates and are less reliant on step size hyper-parameter selection than BSREM reconstructions. Furthermore, SAGA and SVRG can converge significantly faster to the penalised maximum likelihood solution than BSREM, particularly in low count data. Robert Twyman, Simon R. Arridge, Zeljko Kereta, Bangti Jin, Ludovica Brusaferri, Sangtae Ahn, Charles W. Stearns, Brian F. Hutton, Irene A. Burger, Fotis Kotasidis, Kris Thielemans |
IEEE Trans. Medical Imaging | 11 |
| 2021 | Imitation learning for improved 3D PET/MR attenuation correctionabstractThe assessment of the quality of synthesised/pseudo Computed Tomography (pCT) images is commonly measured by an intensity-wise similarity between the ground truth CT and the pCT. However, when using the pCT as an attenuation map (μ-map) for PET reconstruction in Positron Emission Tomography Magnetic Resonance Imaging (PET/MRI) minimising the error between pCT and CT neglects the main objective of predicting a pCT that when used as μ-map reconstructs a pseudo PET (pPET) which is as similar as possible to the gold standard CT-derived PET reconstruction. This observation motivated us to propose a novel multi-hypothesis deep learning framework explicitly aimed at PET reconstruction application. A convolutional neural network (CNN) synthesises pCTs by minimising a combination of the pixel-wise error between pCT and CT and a novel metric-loss that itself is defined by a CNN and aims to minimise consequent PET residuals. Training is performed on a database of twenty 3D MR/CT/PET brain image pairs. Quantitative results on a fully independent dataset of twenty-three 3D MR/CT/PET image pairs show that the network is able to synthesise more accurate pCTs. The Mean Absolute Error on the pCT (110.98 HU ± 19.22 HU) compared to a baseline CNN (172.12 HU ± 19.61 HU) and a multi-atlas propagation approach (153.40 HU ± 18.68 HU), and subsequently lead to a significant improvement in the PET reconstruction error (4.74% ± 1.52% compared to baseline 13.72% ± 2.48% and multi-atlas propagation 6.68% ± 2.06%). Kerstin Kläser 0002, Thomas Varsavsky, Pawel J. Markiewicz, Tom Vercauteren, Alexander Hammers, David Atkinson, Kris Thielemans, Brian F. Hutton, Manuel Jorge Cardoso, Sébastien Ourselin |
Medical Image Anal. | 7 |
| 2020 | PET Reconstruction With Non-Negativity Constraint in Projection Space: Optimization Through Hypo-ConvergenceabstractStandard positron emission tomography (PET) reconstruction techniques are based on maximum-likelihood (ML) optimization methods, such as the maximum-likelihood expectation-maximization (MLEM) algorithm and its variations. Most methodologies rely on a positivity constraint on the activity distribution image. Although this constraint is meaningful from a physical point of view, it can be a source of bias for low-count/high-background PET, which can compromise accurate quantification. Existing methods that allow for negative values in the estimated image usually utilize a modified log-likelihood, and therefore break the data statistics. In this paper, we propose to incorporate the positivity constraint on the projections only, by approximating the (penalized) log-likelihood function by an adequate sequence of objective functions that are easily maximized without constraint. This sequence is constructed such that there is hypo-convergence (a type of convergence that allows the convergence of the maximizers under some conditions) to the original log-likelihood, hence allowing us to achieve maximization with positivity constraint on the projections using simple settings. A complete proof of convergence under weak assumptions is given. We provide results of experiments on simulated data where we compare our methodology with the alternative direction method of multipliers (ADMM) method, showing that our algorithm converges to a maximizer, which stays in the desired feasibility set, with faster convergence than ADMM. We also show that this approach reduces the bias, as compared with MLEM images, in necrotic tumors-which are characterized by cold regions surrounded by hot structures-while reconstructing similar activity values in hot regions. Alexandre Bousse, Matias Courdurier, Élise Émond, Kris Thielemans, Brian F. Hutton, Pablo Irarrazaval, Dimitris Visvikis |
IEEE Trans. Medical Imaging | 4 |
| 2020 | Benefits of Using a Spatially-Variant Penalty Strength With Anatomical Priors in PET ReconstructionabstractIn this study, we explore the use of a spatially-variant penalty strength in penalized image reconstruction using anatomical priors to reduce the dependence of lesion contrast on surrounding activity and lesion location. This work builds on a previous method to make the local perturbation response (LPR) approximately spatially invariant. While the dependence of lesion contrast on the local properties introduced by the anatomical penalty is intentional, the method aims to reduce the influence from surroundings lying along the lines of response (LORs) but not in the penalty neighborhood structure. The method is evaluated using simulated data, assuming that the anatomical information is absent or well-aligned with the corresponding activity images. Since the parallel level sets (PLS) penalty is convex and has shown promising results in the literature, it is chosen as the representative anatomical penalty and incorporated into the previously proposed preconditioned algorithm (L-BFGS-B-PC) for achieving good image quality and fast convergence rate. A 2D disc phantom with a feature at the center and a 3D XCAT thorax phantom with lesions inserted in different slices are used to study how surrounding activity and lesion location affect the visual appearance and quantitative consistency. A bias and noise analysis is also performed with the 2D disc phantom. The consistency of the algorithm convergence rate with respect to different data noise and background levels is also investigated using the XCAT phantom. Finally, an example of reconstruction for a patient dataset with inserted pseudo lesions is used as a demonstration in a clinical context. We show that applying the spatially-variant penalization with PLS can reduce the dependence of the lesion contrast on the surrounding activity and lesion location. It does not affect the bias and noise trade-off curves for matched local resolution. Moreover, when using the proposed penalization, significant improvement in algorithm convergence rate and convergence consistency is observed. Yu-Jung Tsai, Georg Schramm, Sangtae Ahn, Alexandre Bousse, Simon R. Arridge, Johan Nuyts, Brian F. Hutton, Charles W. Stearns, Kris Thielemans |
IEEE Trans. Medical Imaging | 9 |
| 2018 | Fast Quasi-Newton Algorithms for Penalized Reconstruction in Emission Tomography and Further Improvements via PreconditioningabstractThis paper reports on the feasibility of using a quasi-Newton optimization algorithm, limited-memory Broyden-Fletcher-Goldfarb-Shanno with boundary constraints (L-BFGS-B), for penalized image reconstruction problems in emission tomography (ET). For further acceleration, an additional preconditioning technique based on a diagonal approximation of the Hessian was introduced. The convergence rate of L-BFGS-B and the proposed preconditioned algorithm (L-BFGS-B-PC) was evaluated with simulated data with various factors, such as the noise level, penalty type, penalty strength and background level. Data of three18F-FDG patient acquisitions were also reconstructed. Results showed that the proposed L-BFGS-B-PC outperforms L-BFGS-B in convergence rate for all simulated conditions and the patient data. Based on these results, L-BFGS-B-PC shows promise for clinical application. Yu-Jung Tsai, Alexandre Bousse, Matthias J. Ehrhardt, Charles W. Stearns, Sangtae Ahn, Brian F. Hutton, Simon R. Arridge, Kris Thielemans |
IEEE Trans. Medical Imaging | 8 |
| 2017 | Direct Parametric Reconstruction With Joint Motion Estimation/Correction for Dynamic Brain PET DataabstractDirect reconstruction of parametric images from raw photon counts has been shown to improve the quantitative analysis of dynamic positron emission tomography (PET) data. However it suffers from subject motion which is inevitable during the typical acquisition time of 1-2 hours. In this work we propose a framework to jointly estimate subject head motion and reconstruct the motion-corrected parametric images directly from raw PET data, so that the effects of distorted tissue-to-voxel mapping due to subject motion can be reduced in reconstructing the parametric images with motion-compensated attenuation correction and spatially aligned temporal PET data. The proposed approach is formulated within the maximum likelihood framework, and efficient solutions are derived for estimating subject motion and kinetic parameters from raw PET photon count data. Results from evaluations on simulated [11C]raclopride data using the Zubal brain phantom and real clinical [18F]florbetapir data of a patient with Alzheimer's disease show that the proposed joint direct parametric reconstruction motion correction approach can improve the accuracy of quantifying dynamic PET data with large subject motion. Jieqing Jiao, Alexandre Bousse, Kris Thielemans, Ninon Burgos, Philip S. J. Weston, Jonathan M. Schott, David Atkinson, Simon R. Arridge, Brian F. Hutton, Pawel J. Markiewicz, Sébastien Ourselin |
IEEE Trans. Medical Imaging | 3 |
| 2016 | Maximum-Likelihood Joint Image Reconstruction/Motion Estimation in Attenuation-Corrected Respiratory Gated PET/CT Using a Single Attenuation MapabstractThis work provides an insight into positron emission tomography (PET) joint image reconstruction/motion estimation (JRM) by maximization of the likelihood, where the probabilistic model accounts for warped attenuation. Our analysis shows that maximum-likelihood (ML) JRM returns the same reconstructed gates for any attenuation map (μ-map) that is a deformation of a given μ-map, regardless of its alignment with the PET gates. We derived a joint optimization algorithm accordingly, and applied it to simulated and patient gated PET data. We first evaluated the proposed algorithm on simulations of respiratory gated PET/CT data based on the XCAT phantom. Our results show that independently of which μ-map is used as input to JRM: (i) the warped μ-maps correspond to the gated μ-maps, (ii) JRM outperforms the traditional post-registration reconstruction and consolidation (PRRC) for hot lesion quantification and (iii) reconstructed gated PET images are similar to those obtained with gated μ-maps. This suggests that a breath-held μ-map can be used. We then applied JRM on patient data with a μ-map derived from a breath-held high resolution CT (HRCT), and compared the results with PRRC, where each reconstructed PET image was obtained with a corresponding cine-CT gated μ-map. Results show that JRM with breath-held HRCT achieves similar reconstruction to that using PRRC with cine-CT. This suggests a practical low-dose solution for implementation of motion-corrected respiratory gated PET/CT. Alexandre Bousse, Ottavia Bertolli, David Atkinson, Simon R. Arridge, Sébastien Ourselin, Brian F. Hutton, Kris Thielemans |
IEEE Trans. Medical Imaging | 7 |
| 2016 | PET Reconstruction With an Anatomical MRI Prior Using Parallel Level SetsabstractThe combination of positron emission tomography (PET) and magnetic resonance imaging (MRI) offers unique possibilities. In this paper we aim to exploit the high spatial resolution of MRI to enhance the reconstruction of simultaneously acquired PET data. We propose a new prior to incorporate structural side information into a maximum a posteriori reconstruction. The new prior combines the strengths of previously proposed priors for the same problem: it is very efficient in guiding the reconstruction at edges available from the side information and it reduces locally to edge-preserving total variation in the degenerate case when no structural information is available. In addition, this prior is segmentation-free, convex and no a priori assumptions are made on the correlation of edge directions of the PET and MRI images. We present results for a simulated brain phantom and for real data acquired by the Siemens Biograph mMR for a hardware phantom and a clinical scan. The results from simulations show that the new prior has a better trade-off between enhancing common anatomical boundaries and preserving unique features than several other priors. Moreover, it has a better mean absolute bias-to-mean standard deviation trade-off and yields reconstructions with superior relative$\ell ^{2}$-error and structural similarity index. These findings are underpinned by the real data results from a hardware phantom and a clinical patient confirming that the new prior is capable of promoting well-defined anatomical boundaries. Matthias J. Ehrhardt, Pawel J. Markiewicz, Maria Liljeroth, Anna Barnes, Ville Kolehmainen, John S. Duncan, Luis Pizarro, David Atkinson, Brian F. Hutton, Sébastien Ourselin, Kris Thielemans, Simon R. Arridge |
IEEE Trans. Medical Imaging | 11 |
| 2014 | Joint Parametric Reconstruction and Motion Correction Framework for Dynamic PET Data
Jieqing Jiao, Alexandre Bousse, Kris Thielemans, Pawel J. Markiewicz, Ninon Burgos, David Atkinson, Simon R. Arridge, Brian F. Hutton, Sébastien Ourselin |
MICCAI (1) | 3 |
| 2014 | Attenuation Correction Synthesis for Hybrid PET-MR Scanners: Application to Brain StudiesabstractAttenuation correction is an essential requirement for quantification of positron emission tomography (PET) data. In PET/CT acquisition systems, attenuation maps are derived from computed tomography (CT) images. However, in hybrid PET/MR scanners, magnetic resonance imaging (MRI) images do not directly provide a patient-specific attenuation map. The aim of the proposed work is to improve attenuation correction for PET/MR scanners by generating synthetic CTs and attenuation maps. The synthetic images are generated through a multi-atlas information propagation scheme, locally matching the MRI-derived patient's morphology to a database of MRI/CT pairs, using a local image similarity measure. Results show significant improvements in CT synthesis and PET reconstruction accuracy when compared to a segmentation method using an ultrashort-echo-time MRI sequence and to a simplified atlas-based method. Ninon Burgos, Manuel Jorge Cardoso, Kris Thielemans, Marc Modat, Stefano Pedemonte, John C. Dickson, Anna Barnes, Rebekah Ahmed, Colin J. Mahoney, Jonathan M. Schott, John S. Duncan, David Atkinson, Simon R. Arridge, Brian F. Hutton, Sébastien Ourselin |
IEEE Trans. Medical Imaging | 3 |
| 2014 | Including Anatomical and Functional Information in MC Simulation of PET and SPECT Brain Studies. Brain-VISET: A Voxel-Based Iterative MethodabstractMonte Carlo (MC) simulation provides a flexible and robust framework to efficiently evaluate and optimize image processing methods in emission tomography. In this work we present Brain-VISET (Voxel-based Iterative Simulation for Emission Tomography), a method that aims to simulate realistic [ (99m) Tc]-SPECT and [ (18) F]-PET brain databases by including anatomical and functional information. To this end, activity and attenuation maps generated using high-resolution anatomical images from patients were used as input maps in a MC projector to simulate SPECT or PET sinograms. The reconstructed images were compared with the corresponding real SPECT or PET studies in an iterative process where the activity inputs maps were being modified at each iteration. Datasets of 30 refractory epileptic patients were used to assess the new method. Each set consisted of structural images (MRI and CT) and functional studies (SPECT and PET), thereby allowing the inclusion of anatomical and functional variability in the simulation input models. SPECT and PET sinograms were obtained using the SimSET package and were reconstructed with the same protocols as those employed for the clinical studies. The convergence of Brain-VISET was evaluated by studying the behavior throughout iterations of the correlation coefficient, the quotient image histogram and a ROI analysis comparing simulated with real studies. The realism of generated maps was also evaluated. Our findings show that Brain-VISET is able to generate realistic SPECT and PET studies and that four iterations is a suitable number of iterations to guarantee a good agreement between simulated and real studies. Berta Martí Fuster, Oscar Esteban, Kris Thielemans, Xavier Setoain, Domènec Ros, Javier Pavía |
IEEE Trans. Medical Imaging | 3 |
| 2004 | Object dependency of resolution in reconstruction algorithms with interiteration filtering applied to PET dataabstractIn this paper, we study the resolution properties of those algorithms where a filtering step is applied after every iteration. As concrete examples we take filtered preconditioned gradient descent algorithms for the Poisson log likelihood for PET emission data. For nonlinear estimators, resolution can be characterized in terms of the linearized local impulse response (LLIR). We provide analytic approximations for the LLIR for the class of algorithms mentioned above. Our expressions clearly show that when interiteration filtering (with linear filters) is used, the resolution properties are, in most cases, spatially varying, object dependent and asymmetric. These nonuniformities are solely due to the interaction between the filtering step and the Poisson noise model. This situation is similar to penalized likelihood reconstructions as studied previously in the literature. In contrast, nonregularized and postfiltered maximum-likelihood expectation maximization (MLEM) produce images with nearly "perfect" uniform resolution when convergence is reached. We use the analytic expressions for the LLIR to propose three different approaches to obtain nearly object independent and uniform resolution. Two of them are based on calculating filter coefficients on a pixel basis, whereas the third one chooses an appropriate preconditioner. These three approaches are tested on simulated data for the filtered MLEM algorithm or the filtered separable paraboloidal surrogates algorithm. The evaluation confirms that images obtained using our proposed regularization methods have nearly object independent and uniform resolution. Sanida Mustafovic, Kris Thielemans |
IEEE Trans. Medical Imaging | 2 |