VLDB 2026 Research / reviewers in the wild / expert
Angelos Karlas
dblp:165/8040
· DBLP profile ↗
6ranked-venue papers
0as first author
5since 2021 · last 2025
0000-0002-6340-2555ORCID · verified
Domains — the database's venue-derived domains; a paper can count in several
Applied, interdisciplinary, general and emerging computing · 6 · 5 since 2021Graphics, computer vision, multimedia, augmented reality and games · 2 · 2 since 2021
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2025 | Intelligent Virtual Sonographer (IVS): Enhancing Physician-Robot-Patient Communication
Tianyu Song 0002, Feng Li 0034, Yuan Bi, Angelos Karlas, Amir Yousefi, Daniela Branzan, Zhongliang Jiang, Ulrich Eck, Nassir Navab |
MICCAI (10) | 4 |
| 2025 | Synomaly noise and multi-stage diffusion: A novel approach for unsupervised anomaly detection in medical imagesabstractAnomaly detection in medical imaging plays a crucial role in identifying pathological regions across various imaging modalities, such as brain MRI, liver CT, and carotid ultrasound (US). However, training fully supervised segmentation models is often hindered by the scarcity of expert annotations and the complexity of diverse anatomical structures. To address these issues, we propose a novel unsupervised anomaly detection framework based on a diffusion model that incorporates a synthetic anomaly (Synomaly) noise function and a multi-stage diffusion process. Synomaly noise introduces synthetic anomalies into healthy images during training, allowing the model to effectively learn anomaly removal. The multi-stage diffusion process is introduced to progressively denoise images, preserving fine details while improving the quality of anomaly-free reconstructions. The generated high-fidelity counterfactual healthy images can further enhance the interpretability of the segmentation models, as well as provide a reliable baseline for evaluating the extent of anomalies and supporting clinical decision-making. Notably, the unsupervised anomaly detection model is trained purely on healthy images, eliminating the need for anomalous training samples and pixel-level annotations. We validate the proposed approach on brain MRI, liver CT datasets, and carotid US. The experimental results demonstrate that the proposed framework outperforms existing state-of-the-art unsupervised anomaly detection methods, achieving performance comparable to fully supervised segmentation models in the US dataset. Ablation studies further highlight the contributions of Synomaly noise and the multi-stage diffusion process in improving anomaly segmentation. These findings underscore the potential of our approach as a robust and annotation-efficient alternative for medical anomaly detection. Code:https://github.com/yuan-12138/Synomaly. Yuan Bi, Lucie Huang, Ricarda Clarenbach, Reza Ghotbi, Angelos Karlas, Nassir Navab, Zhongliang Jiang |
Medical Image Anal. | 5 |
| 2025 | Robot-Assisted Deep Venous Thrombosis Ultrasound Examination Using Virtual FixtureabstractDeep Venous Thrombosis (DVT) is a common vascular disease with blood clots inside deep veins, which may block blood flow or even cause a life-threatening pulmonary embolism. A typical exam for DVT using ultrasound (US) imaging is by pressing the target vein until its lumen is fully compressed. However, the compression exam is highly operator-dependent. To alleviate intra-and inter-variations, we present a robotic US system with a novel hybrid force motion control scheme ensuring position and force tracking accuracy, and soft landing of the probe onto the target surface. In addition, a path-based virtual fixture is proposed to realize easy human-robot interaction for repeat compression operation at the lesion location. To ensure the biometric measurements obtained in different examinations are comparable, the 6D scanning path is determined in a coarse-to-fine manner using both an external RGBD camera and US images. The RGBD camera is first used to extract a rough scanning path on the object. Then, the segmented vascular lumen from US images are used to optimize the scanning path to ensure the visibility of the target object. To generate a continuous scan path for developing virtual fixtures, an arc-length based path fitting model considering both position and orientation is proposed. Finally, the whole system is evaluated on a human-like arm phantom with an uneven surface. The code (https://github.com/dianyeHuang/RobDVTUS) and intuitive demonstration video (https://www.youtube.com/ watch?v=3xFyqU1rV8c) can be publicly accessed.Note to Practitioners—Robotic ultrasound (US) systems have attracted attention for various applications in the past decades. However, the existing studies are not mature and intelligent enough for some challenging applications, such as DVT exam, which requires rich contact interaction between patients and clinicians. To tackle with this challenge, this study presents a novel human-centric robotic DVT exam program using the technique of virtual fixture. The coarse-to-fine path planning module ensures the repeatability of US acquisitions carried out at different times. During DVT exam, the proposed continuous 6D path virtual fixture can guide clinicians to freely move the probe along the scan path while limiting the probe motion in other directions. In order to perform the compress-release exam, a decoupled position/force controller is developed to precisely generate the contact force conveyed by clinicians and to restrict the probe motion along the probe centerline. We believe such a robot-assisted system is a promising solution to take both advantages of robots about the accuracy and repeatability and human operators about the advanced physiological knowledge. Dianye Huang, Chenguang Yang 0001, Mingchuan Zhou, Angelos Karlas, Nassir Navab, Zhongliang Jiang |
IEEE Trans Autom. Sci. Eng. | 4 |
| 2025 | VibNet: Vibration-Boosted Needle Detection in Ultrasound ImagesabstractPrecise percutaneous needle detection is crucial for ultrasound (US)-guided interventions. However, inherent limitations such as speckles, needle-like artifacts, and low resolution make it challenging to robustly detect needles, especially when their visibility is reduced or imperceptible. To address this challenge, we propose VibNet, a learning-based framework designed to enhance the robustness and accuracy of needle detection in US images by leveraging periodic vibration applied externally to the needle shafts. VibNet integrates neural Short-Time Fourier Transform and Hough Transform modules to achieve successive sub-goals, including motion feature extraction in the spatiotemporal space, frequency feature aggregation, and needle detection in the Hough space. Due to the periodic subtle vibration, the features are more robust in the frequency domain than in the image intensity domain, making VibNet more effective than traditional intensity-based methods. To demonstrate the effectiveness of VibNet, we conducted experiments on distinct ex vivo porcine and bovine tissue samples. The results obtained on porcine samples demonstrate that VibNet effectively detects needles even when their visibility is severely reduced, with a tip error of ${1}.{61}\pm {1}.{56}~\textit {mm}$ compared to ${8}.{15}\pm {9}.{98}~\textit {mm}$ for UNet and ${6}.{63}\pm {7}.{58}~\textit {mm}$ for WNet, and a needle direction error of ${1}.{64}\pm {1}.{86}^{\circ }$ compared to ${9}.{29}~\pm ~{15}.{30}^{\circ }$ for UNet and ${8}.{54}~\pm ~{17}.{92}^{\circ }$ for WNet. Code: https://github.com/marslicy/VibNet. Dianye Huang, Chenyang Li 0004, Angelos Karlas, Xiangyu Chu, K. W. Samuel Au, Nassir Navab, Zhongliang Jiang |
IEEE Trans. Medical Imaging | 3 |
| 2023 | MI-SegNet: Mutual Information-Based US Segmentation for Unseen Domain Generalization
Yuan Bi, Zhongliang Jiang, Ricarda Clarenbach, Reza Ghotbi, Angelos Karlas, Nassir Navab |
MICCAI (4) | 5 |
| 2020 | A Synthetic Total Impulse Response Characterization Method for Correction of Hand-Held Optoacoustic ImagesabstractThe impulse response of optoacoustic (photoacoustic) tomographic imaging system depends on several system components, the characteristics of which can influence the quality of reconstructed images. The effect of these system components on reconstruction quality have not been considered in detail so far. Here we combine sparse measurements of the total impulse response (TIR) with a geometric acoustic model to obtain a full characterization of the TIR of a handheld optoacoustic tomography system with concave limited-view acquisition geometry. We then use this synthetic TIR to reconstruct data from phantoms and healthy human volunteers, demonstrating improvements in image resolution and fidelity. The higher accuracy of optoacoustic tomographic reconstruction with TIR correction further improves the diagnostic capability of handheld optoacoustic tomographic systems. Kaushik Basak Chowdhury, Jaya Prakash, Angelos Karlas, Dominik Jüstel, Vasilis Ntziachristos |
IEEE Trans. Medical Imaging | 3 |