Otto I. Szentesi

dblp:167/6482 · DBLP profile ↗
← Back
2ranked-venue papers
2as first author
0since 2021 · last 1986
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Computer networks · 2 · 2 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Computer networks
2 papers
Optical networks · 56% Network management and operations · 44%

Topics — the 2 heaviest of 3, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Network management and operations
network restoration
0.021986
Reliability of Optical Fibers, Cables, and Splices · IEEE J. Sel. Areas Commun. 1986
Field Experience with Fiber-Optic Cable Installation, Splicing, Reliability, and Maintenance · IEEE J. Sel. Areas Commun. 1983
Optical networks
optical fiber cable
0.021986
Reliability of Optical Fibers, Cables, and Splices · IEEE J. Sel. Areas Commun. 1986
Field Experience with Fiber-Optic Cable Installation, Splicing, Reliability, and Maintenance · IEEE J. Sel. Areas Commun. 1983
YearPublicationVenuePosition
1986 Reliability of Optical Fibers, Cables, and Splices
abstract
This paper discusses fiber characteristics and cable design considerations that affect cable reliability. Installed cable and splice reliability data are presented, and it is concluded that intrinsic cable and splice reliability is very high. Cable failures are dominated by uncontrollable factors, and the highest failure mode is "backhoe blackout." Finally, restoration issues are discussed.
Otto I. Szentesi
IEEE J. Sel. Areas Commun.1
1983 Field Experience with Fiber-Optic Cable Installation, Splicing, Reliability, and Maintenance
abstract
The experience obtained during the installation of more than 700 sheath km of fiber-optic cable is summarized. These include in-building, underground (duct), aerial, buried, and underwater installations. In general, no special precautions are required except to maintain the specified pull tension and cable bend radius. Field splicing is discussed and results are given on splice losses with and without splice loss monitoring with the optical time domain reflectometer. A 28 percent learning curve for fusion splicing is derived. Reliability data on 312 sheath km of installed cable and field splices are presented. Most of the cable failures were in the "uncontrollable extrinsic category," and most of these were due to complete cable cuts. Finally, restoration is reviewed with emphasis on troubleshooting, repair, emergency restoration, and offset breaks.
Otto I. Szentesi