Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Mohammad Haghighipanah

dblp:173/6323 · DBLP profile ↗
← Back
4ranked-venue papers
2as first author
0since 2021 · last 2016
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 4 · 2 first-authorSystems, architecture and hardware · 4 · 2 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
2 papers
Robot manipulation · 38% Robot navigation and mapping · 38% Probabilistic and Bayesian machine learning · 19%
Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%

Topics — the 8 heaviest of 9, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Robot manipulation
cable-driven robot
0.212016
Hysteresis model of longitudinally loaded cable for cable driven robots and identification of the parameters · ICRA 2016
Robotics › Robot navigation and mapping › state estimation › kinematic state estimation
joint angle estimation
0.212016
Unscented Kalman Filter and 3D vision to improve cable driven surgical robot joint angle estimation · ICRA 2016
Robotics › Robot navigation and mapping
state estimation
0.212016
Unscented Kalman Filter and 3D vision to improve cable driven surgical robot joint angle estimation · ICRA 2016
Robotics › Robot manipulation › medical robotics
surgical robotics
0.212016
Unscented Kalman Filter and 3D vision to improve cable driven surgical robot joint angle estimation · ICRA 2016
Machine learning › Probabilistic and Bayesian machine learning › statistical inference › bayesian inference › bayesian filtering › kalman filtering
unscented kalman filter
0.212016
Unscented Kalman Filter and 3D vision to improve cable driven surgical robot joint angle estimation · ICRA 2016
Medical and health informatics › surgical robotics
minimally invasive surgery
0.212016
Dynamic modeling of cable driven elongated surgical instruments for sensorless grip force estimation · ICRA 2016
Medical and health informatics
surgical robotics
0.212016
Dynamic modeling of cable driven elongated surgical instruments for sensorless grip force estimation · ICRA 2016
Robotics › Motion planning and robot control › robot control
cable-driven robot control
0.112016
Hysteresis model of longitudinally loaded cable for cable driven robots and identification of the parameters · ICRA 2016

Methods — techniques the papers use, named apart from their topics

unscented kalman filter · 0.5stereo vision · 0.2genetic algorithm · 0.2dynamic modeling · 0.2duhem operator · 0.2bounding filter · 0.2bouc-wen hysteresis model · 0.2
YearPublicationVenuePosition
2016 Unscented Kalman Filter and 3D vision to improve cable driven surgical robot joint angle estimation
abstract
Cable driven manipulators are popular in surgical robots due to compact design, low inertia, and remote actuation. In these manipulators, encoders are usually mounted on the motor, and joint angles are estimated based on transmission kinematics. However, due to non-linear properties of cables such as cable stretch, lower stiffness, and uncertainties in kinematic model parameters, the precision of joint angle estimation is limited with transmission kinematics approach. To improve the positioning of these manipulators, we use a pair of low cost stereo camera as the observation for joint angles and we input these noisy measurements into an Unscented Kalman Filter (UKF) for state estimation. We use the dual UKF to estimate cable parameters and states offline. We evaluated the effectiveness of the proposed method on a Raven-II experimental surgical research platform. Additional encoders at the joint output were employed as a reference system. From the experiments, the UKF improved the accuracy of joint angle estimation by 33- 72%. Also, we tested the reliability of state estimation under camera occlusion. We found that when the system dynamics is tuned with offline UKF parameter estimation, the camera occlusion has no effect on the online state estimation.
Mohammad Haghighipanah, Muneaki Miyasaka, Yangming Li, Blake Hannaford
ICRA1
2016 Dynamic modeling of cable driven elongated surgical instruments for sensorless grip force estimation
abstract
Haptic feedback plays a key role in surgeries, but it is still a missing component in robotic Minimally Invasive Surgeries. This paper proposes a dynamic model-based sensorless grip force estimation method to address the haptic perception problem for commonly used elongated cable-driven surgical instruments. Cable and cable-pulley properties are studied for dynamic modeling; grip forces, along with driven motor and gripper jaw positions and velocities are jointly estimated with Unscented Kalman Filter and only motor encoder readings and motor output torques are assumed to be known. A bounding filter is used to compensate for model inaccuracy and to improve method robustness. The proposed method was validated on a 10mm gripper which is driven by a Raven-II surgical robot. The gripper was equipped with 1-dimensional force sensors which served as ground truth data. The experimental results showed that the proposed method provides sufficiently good grip force estimation, while only motor encoder and the motor torques are used as observations.
Yangming Li, Muneaki Miyasaka, Mohammad Haghighipanah, Blake Hannaford
ICRA3
2016 Hysteresis model of longitudinally loaded cable for cable driven robots and identification of the parameters
abstract
In this paper, we propose model of longitudinally loaded cable based on the Bouc-Wen hysteresis model and within the framework of the Duhem operator. By optimizing the 9 hysteresis model parameters with a genetic algorithm, the proposed model is shown to be capable of representing quasi-static response of two different diameter cables, 0.61 mm (thin) and 1.19 mm (thick), used for the RAVEN II surgical robotic surgery platform. The construction of the cable is 7 strands with 19 individual wires per strand. Furthermore, it is shown that the dynamic response of the cables are captured by adding a linear damping term. The hysteresis model and linear damper with the optimized parameters accurately models a longitudinal vibration test result in terms of frequency, steady state stretch, and logarithmic decrement. Energy dissipation due solely to the hysteresis term is approximately calculated to be 57 and 71% of the total energy loss for the thin and thick cables respectively. The proposed model may be used for cables with different contraction and diameter and can be applied for control of cable driven robots in which cables are stretched longitudinally without large excitation of other modes.
Muneaki Miyasaka, Mohammad Haghighipanah, Yangming Li, Blake Hannaford
ICRA2
2015 Improving position precision of a servo-controlled elastic cable driven surgical robot using Unscented Kalman Filter
abstract
Cable driven power transmission is popular in many manipulator applications including medical arms. In spite of advantages obtained by removing motors from the mechanism, cable transmission introduces higher non-linearity and more uncertainties such as cable stretch and cable coupling. In order to improve the control precision and robustness of the Raven-II surgical robot, particularly for automation applications, the Unscented Kalman Filter (UKF) was adopted for state estimation. The UKF estimated state variables of the Raven-II dynamic model from sensor data. The dual UKF was used offline to estimate cable coupling parameters. The experimental results showed that the proposed method improved joint position estimation precision and the estimation consistency, especially on the more elastic links. The improvements for links 2 and 3 of the Raven were 36.76%, and 62.99%, respectively. For link 1 the improvement was 1.43% because the transmission is very stiff.
Mohammad Haghighipanah, Yangming Li, Muneaki Miyasaka, Blake Hannaford
IROS1