Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Manas Kumar Jena

dblp:174/0922 · DBLP profile ↗
← Back
3ranked-venue papers
2as first author
1since 2021 · last 2025
0000-0003-1134-1348ORCID · verified

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 1 · 1 first-authorSecurity and privacy · 1 · 1 since 2021Applied, interdisciplinary, general and emerging computing · 1 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Network and information security
1 paper
Cyber-physical and IoT security · 67% Network security · 33%
Interdisciplinary, comprehensive, and emerging computing
1 paper
Energy systems and smart grids · 100%

Topics — the 4 heaviest of 5, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Network security › intrusion detection and prevention › intrusion detection
attack detection
0.912025
A Dynamic State Estimation-Based Cyberattack Detection Scheme to Supervise Legacy Pilot Protection Operation · IEEE Trans. Inf. Forensics Secur. 2025
Cyber-physical and IoT security › smart grid security
false data injection attack detection
0.912025
A Dynamic State Estimation-Based Cyberattack Detection Scheme to Supervise Legacy Pilot Protection Operation · IEEE Trans. Inf. Forensics Secur. 2025
Cyber-physical and IoT security
smart grid security
0.912025
A Dynamic State Estimation-Based Cyberattack Detection Scheme to Supervise Legacy Pilot Protection Operation · IEEE Trans. Inf. Forensics Secur. 2025
Energy systems and smart grids › power system automation
substation automation
0.312025
A Dynamic State Estimation-Based Cyberattack Detection Scheme to Supervise Legacy Pilot Protection Operation · IEEE Trans. Inf. Forensics Secur. 2025

Methods — techniques the papers use, named apart from their topics

unscented kalman filter · 1.7dynamic state estimation · 1.7
YearPublicationVenuePosition
2025 A Dynamic State Estimation-Based Cyberattack Detection Scheme to Supervise Legacy Pilot Protection Operation
abstract
The transition of power systems toward digital substations has brought numerous advantages to substation automation. However, this digital transformation exposes substations to various cyberattacks. Thus, ensuring the integrity and availability of power system data has emerged as a critical concern in modern power system networks. A crucial cybersecurity concern is pilot protection, with its security being of utmost importance in bulk power system networks to safeguard against significant disturbances and blackouts, as well as to facilitate fast fault-clearing operations. This paper introduces a dynamic state estimation (DSE) technique to supervise the operation of pilot protection scheme. The proposed scheme accurately estimates transmission line impedance and uses this estimation to supervise the legacy pilot protection scheme. The method employs network physical laws, sampled value measurements, and an Unscented Kalman Filter (UKF) technique to enhance the cybersecurity aspects of the pilot protection scheme. Additionally, the cybersecurity of the DSE-based pilot protection supervision scheme is evaluated against cyberattacks such as denial of service (DoS) and false data injection (FDI). The simulation results, validated using the IEEE 9 bus test system, demonstrate the effectiveness of the proposed method for pilot protection supervision.
Syed Shafiulla, Manas Kumar Jena
IEEE Trans. Inf. Forensics Secur.2
2018 A New Approach to Power System Disturbance Assessment Using Wide-Area Postdisturbance Records
abstract
This paper presents an empirical wavelet transform (EWT) based approach to perform postmortem analysis of wide-area measurement (WAM) based signals. The commonly used empirical mode decomposition (EMD) has limitations such as mode mixing, sensitivity to noise, and sampling rate. The decomposition provided by EWT is more consistent as compared to EMD. The modes revealed by the EWT help in extracting dynamic patterns of different power system disturbances. The dynamic patterns extracted through EWT-based decomposition are further used as inputs to a data-mining tool known as random forest, to build a wide-area disturbance classifier (WADC) model. The efficient mode extraction quality of the EWT-based signal processing tool is analyzed for WAM data recorded on Northern Grid of Indian Power System. The performance of the WADC is validated on IEEE 39-bus New England test system. The results provide improved performance in terms of decomposition quality and classification accuracy.
Manas Kumar Jena, Bijaya K. Panigrahi, S. R. Samantaray 0001
IEEE Trans. Ind. Informatics1
2016 Data-Mining-Based Intelligent Differential Relaying for Transmission Lines Including UPFC and Wind Farms
abstract
This paper presents a data-mining-based intelligent differential relaying scheme for transmission lines, including flexible ac transmission system device, such as unified power flow controller (UPFC) and wind farms. Initially, the current and voltage signals are processed through extended Kalman filter phasor measurement unit for phasor estimation, and 21 potential features are computed at both ends of the line. Once the features are extracted at both ends, the corresponding differential features are derived. These differential features are fed to a data-mining model known as decision tree (DT) to provide the final relaying decision. The proposed technique has been extensively tested for single-circuit transmission line, including UPFC and wind farms with in-feed, double-circuit line with UPFC on one line and wind farm as one of the substations with wide variations in operating parameters. The test results obtained from simulation as well as in real-time digital simulator testing indicate that the DT-based intelligent differential relaying scheme is highly reliable and accurate with a response time of 2.25 cycles from the fault inception.
Manas Kumar Jena, S. R. Samantaray 0001
IEEE Trans. Neural Networks Learn. Syst.1