Demo Data from VLDB 2026 / reviewers in the wild / expert
Lisa Story
dblp:199/5217
· DBLP profile ↗
4ranked-venue papers
0as first author
3since 2021 · last 2025
0000-0001-9328-9592ORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Applied, interdisciplinary, general and emerging computing · 3 · 3 since 2021Graphics, computer vision, multimedia, augmented reality and games · 2 · 1 since 2021
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Computer graphics and multimedia
1 paper |
Visualization and visual analytics · 100% | |
| Interdisciplinary, comprehensive, and emerging computing
1 paper |
Medical and health informatics · 100% |
Topics — the 1 heaviest of 2, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Visualization and visual analytics
medical visualization |
0.3 | 1 | 2017 | Placenta Maps: In Utero Placental Health Assessment of the Human Fetus · IEEE Trans. Vis. Comput. Graph. 2017 |
Methods — techniques the papers use, named apart from their topics
surface slicing · 0.6motion compensation · 0.6automatic segmentation · 0.6
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2025 | Fetal body organ T2* relaxometry at low field strength (FOREST)abstractFetal Magnetic Resonance Imaging (MRI) at low field strengths is an exciting new field in both clinical and research settings. Clinical low field (0.55T) scanners are beneficial for fetal imaging due to their reduced susceptibility-induced artifacts, increased T2* values, and wider bore (widening access for the increasingly obese pregnant population). However, the lack of standard automated image processing tools such as segmentation and reconstruction hampers wider clinical use. In this study, we present the Fetal body Organ T2* RElaxometry at low field STrength (FOREST) pipeline that analyzes ten major fetal body organs. Dynamic multi-echo multi-gradient sequences were acquired and automatically reoriented to a standard plane, reconstructed into a high-resolution volume using deformable slice-to-volume reconstruction, and then automatically segmented into ten major fetal organs. We extensively validated FOREST using an inter-rater quality analysis. We then present fetal T2* body organ growth curves made from 100 control subjects from a wide gestational age range (17-40 gestational weeks) in order to investigate the relationship of T2* with gestational age. The T2* values for all organs except the stomach and spleen were found to have a relationship with gestational age (p<0.05). FOREST is robust to fetal motion, and can be used for both normal and fetuses with pathologies. Low field fetal MRI can be used to perform advanced MRI analysis, and is a viable option for clinical scanning. Kelly Payette, Alena Uus, Jordina Aviles Verdera, Megan Hall, Alexia Egloff, Maria Deprez, Raphaël Tomi-Tricot, Joseph V. Hajnal, Mary A. Rutherford, Lisa Story, Jana Hutter |
Medical Image Anal. | 10 |
| 2024 | A flexible generative algorithm for growing in silico placentasabstractThe placenta is crucial for a successful pregnancy, facilitating oxygen exchange and nutrient transport between mother and fetus. Complications like fetal growth restriction and pre-eclampsia are linked to placental vascular structure abnormalities, highlighting the need for early detection of placental health issues. Computational modelling offers insights into how vascular architecture correlates with flow and oxygenation in both healthy and dysfunctional placentas. These models use synthetic networks to represent the multiscale feto-placental vasculature, but current methods lack direct control over key morphological parameters like branching angles, essential for predicting placental dysfunction. We introduce a novel generative algorithm for creating in silico placentas, allowing user-controlled customisation of feto-placental vasculatures, both as individual components (placental shape, chorionic vessels, placentone) and as a complete structure. The algorithm is physiologically underpinned, following branching laws (i.e. Murray's Law), and is defined by four key morphometric statistics: vessel diameter, vessel length, branching angle and asymmetry. Our algorithm produces structures consistent with in vivo measurements and ex vivo observations. Our sensitivity analysis highlights how vessel length variations and branching angles play a pivotal role in defining the architecture of the placental vascular network. Moreover, our approach is stochastic in nature, yielding vascular structures with different topological metrics when imposing the same input settings. Unlike previous volume-filling algorithms, our approach allows direct control over key morphological parameters, generating vascular structures that closely resemble real vascular densities and allowing for the investigation of the impact of morphological parameters on placental function in upcoming studies. Diana C. de Oliveira, Hani Cheikh Sleiman, Kelly Payette, Jana Hutter, Lisa Story, Joseph V. Hajnal, Daniel C. Alexander, Rebecca Shipley, Paddy Slator |
PLoS Comput. Biol. | 5 |
| 2023 | An Automated Pipeline for Quantitative T2* Fetal Body MRI and Segmentation at Low FieldabstractFetal Magnetic Resonance Imaging at low field strengths is emerging as an exciting direction in perinatal health. Clinical low field (0.55T) scanners are beneficial for fetal imaging due to their reduced susceptibility-induced artefacts, increased T2* values, and wider bore (widening access for the increasingly obese pregnant population). However, the lack of standard automated image processing tools such as segmentation and reconstruction hampers wider clinical use. In this study, we introduce a semi-automatic pipeline using quantitative MRI for the fetal body at low field strength resulting in fast and detailed quantitative T2* relaxometry analysis of all major fetal body organs. Multi-echo dynamic sequences of the fetal body were acquired and reconstructed into a single high-resolution volume using deformable slice-to-volume reconstruction, generating both structural and quantitative T2* 3D volumes. A neural network trained using a semi-supervised approach was created to automatically segment these fetal body 3D volumes into ten different organs (resulting in dice values > 0.74 for 8 out of 10 organs). The T2* values revealed a strong relationship with GA in the lungs, liver, and kidney parenchyma (R 2 >0.5). This pipeline was used successfully for a wide range of GAs (17–40 weeks), and is robust to motion artefacts. Low field fetal MRI can be used to perform advanced MRI analysis, and is a viable option for clinical scanning. Kelly Payette, Alena Uus, Jordina Aviles Verdera, Carla Avena Zampieri, Megan Hall, Lisa Story, Maria Deprez, Mary A. Rutherford, Joseph V. Hajnal, Sébastien Ourselin, Raphaël Tomi-Tricot, Jana Hutter |
MICCAI (7) | 6 |
| 2017 | Placenta Maps: In Utero Placental Health Assessment of the Human FetusabstractThe human placenta is essential for the supply of the fetus. To monitor the fetal development, imaging data is acquired using (US). Although it is currently the gold-standard in fetal imaging, it might not capture certain abnormalities of the placenta. (MRI) is a safe alternative for the in utero examination while acquiring the fetus data in higher detail. Nevertheless, there is currently no established procedure for assessing the condition of the placenta and consequently the fetal health. Due to maternal respiration and inherent movements of the fetus during examination, a quantitative assessment of the placenta requires fetal motion compensation, precise placenta segmentation and a standardized visualization, which are challenging tasks. Utilizing advanced motion compensation and automatic segmentation methods to extract the highly versatile shape of the placenta, we introduce a novel visualization technique that presents the fetal and maternal side of the placenta in a standardized way. Our approach enables physicians to explore the placenta even in utero. This establishes the basis for a comparative assessment of multiple placentas to analyze possible pathologic arrangements and to support the research and understanding of this vital organ. Additionally, we propose a three-dimensional structure-aware surface slicing technique in order to explore relevant regions inside the placenta. Finally, to survey the applicability of our approach, we consulted clinical experts in prenatal diagnostics and imaging. We received mainly positive feedback, especially the applicability of our technique for research purposes was appreciated. Haichao Miao, Gabriel Mistelbauer, Alexey Karimov, Amir Alansary, Alice Davidson, David Lloyd 0003, Mellisa Damodaram, Lisa Story, Jana Hutter, Joseph V. Hajnal, Mary A. Rutherford, Bernhard Preim, Bernhard Kainz, M. Eduard Gröller |
IEEE Trans. Vis. Comput. Graph. | 8 |