VLDB 2026 Research / reviewers in the wild / expert
Yinzhe Wu 0001
dblp:203/0126-1
· DBLP profile ↗
11ranked-venue papers
1as first author
11since 2021 · last 2026
0009-0003-7957-8816ORCID · conflict
Domains — the database's venue-derived domains; a paper can count in several
Applied, interdisciplinary, general and emerging computing · 9 · 1 first-author · 9 since 2021Graphics, computer vision, multimedia, augmented reality and games · 3 · 3 since 2021Artificial intelligence and machine learning · 1 · 1 since 2021
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2026 | Explicit differentiable slicing and global deformation for cardiac mesh reconstructionabstractThree-dimensional (3D) mesh reconstruction of the cardiac anatomy from medical images is useful for shape and motion measurements and biophysics simulations. However, 3D medical images are often acquired as 2D slices that are sparsely sampled (e.g., large slice spacing) and noisy, and 3D mesh reconstruction on such data is a challenging task. Traditional voxel-based approaches utilize non-differentiable pre- and post-processing that compromises fidelity to images, while mesh-level deep learning approaches require large 3D mesh annotations that are difficult to obtain. Differentiable cross-domain supervision from 2D images to 3D meshes is therefore crucial for enabling end-to-end optimization in medical imaging. While there have been attempts to approximate the voxelization and slicing of meshes that are being optimized, there has not yet been a method for directly using 2D slices to supervise 3D mesh reconstruction in a differentiable manner. Here, we propose a novel explicit differentiable voxelization and slicing (DVS) algorithm allowing gradient backpropagation to a 3D mesh from its slices, which facilitates refined mesh optimization directly supervised by the losses defined on 2D images. Further, we propose an innovative framework for extracting patient-specific left ventricle (LV) meshes from medical images by coupling DVS with a graph harmonic deformation (GHD) mesh morphing descriptor of cardiac shape that naturally preserves mesh quality and smoothness during optimization. The proposed framework achieves state-of-the-art performance in cardiac mesh reconstruction tasks from densely sampled (CT) as well as sparsely sampled (MRI stack with few slices) images, outperforming alternatives, including Marching Cubes, statistical shape models, algorithms with vertex-based mesh morphing algorithms and alternative methods for image-supervision of mesh reconstruction. Experimental results demonstrate that our method achieves an overall Dice score of 90% during a sparse fitting on multi-datasets. The proposed method can further quantify clinically useful parameters such as ejection fraction and global myocardial strains, closely matching the ground truth and outperforming the traditional voxel-based approach in sparse images. Yihao Luo, Dario Sesia, Fanwen Wang, Yinzhe Wu 0001, Wenhao Ding, Md. Kamrul Hasan 0002, Fadong Shi, Anoop Shah, Amit Kaura, Jamil Mayet, Guang Yang 0006, Choon Hwai Yap |
Medical Image Anal. | 4 |
| 2026 | From Coarse to Continuous: Progressive Refinement Implicit Neural Representation for Motion-Robust Anisotropic MRI ReconstructionabstractIn motion-robust magnetic resonance imaging (MRI), slice-to-volume reconstruction is critical for recovering anatomically consistent 3D brain volumes from 2D slices, especially under accelerated acquisitions or patient motion. However, this task remains challenging due to hierarchical structural disruptions. It includes local detail loss from k-space undersampling, global structural aliasing caused by motion, and volumetric anisotropy. Therefore, we propose a progressive refinement implicit neural representation (PR-INR) framework. Our PR-INR unifies motion correction, structural refinement, and volumetric synthesis within a geometry-aware coordinate space. Specifically, a motion-aware diffusion module is first employed to generate coarse volumetric reconstructions that suppress motion artifacts and preserve global anatomical structures. Then, we introduce an implicit detail restoration module that performs residual refinement by aligning spatial coordinates with visual features. It corrects local structures and enhances boundary precision. Further, a voxel continuous-aware representation module represents the image as a continuous function over 3D coordinates. It enables accurate inter-slice completion and high-frequency detail recovery. We evaluate PR-INR on five public MRI datasets under various motion conditions (3% and 5% displacement), undersampling rates (4x and 8x) and slice resolutions (scale = 5). Experimental results demonstrate that PR-INR outperforms state-of-the-art methods in both quantitative reconstruction metrics and visual quality. It further shows generalization and robustness across diverse unseen domains. Zhenxuan Zhang, Lipei Zhang, Yanqi Cheng, Zi Wang 0005, Fanwen Wang, Haosen Zhang, Yinzhe Wu 0001, Angelica I. Avilés-Rivero, Zhifan Gao, Guang Yang 0006, Peter J. Lally |
IEEE Trans. Image Process. | 8 |
| 2026 | Toward Modality- and Sampling-Universal Learning Strategies for Accelerating Cardiovascular Imaging: Summary of the CMRxRecon2024 ChallengeabstractCardiovascular health is vital to human well-being, and cardiac magnetic resonance (CMR) imaging is considered the clinical reference standard for diagnosing cardiovascular disease. However, its adoption is hindered by long scan times, complex contrasts, and inconsistent quality. While deep learning methods perform well on specific CMR imaging sequences, they often fail to generalize across modalities and sampling schemes. The lack of benchmarks for high-quality, fast CMR image reconstruction further limits technology comparison and adoption. The CMRxRecon2024 challenge, attracting over 200 teams from 18 countries, addressed these issues with two tasks: generalization to unseen modalities and robustness to diverse undersampling patterns. We introduced the largest public multi-modality CMR raw dataset, an open benchmarking platform, and shared code. Analysis of the best-performing solutions revealed that prompt-based adaptation and enhanced physics-driven consistency enabled strong cross-scenario performance. These findings establish principles for generalizable reconstruction models and advance clinically translatable AI in cardiovascular imaging. Fanwen Wang, Zi Wang 0005, Yan Li 0064, Chen Qin, Shuo Wang 0011, Kunyuan Guo, Mengting Sun, Mingkai Huang, Michael Tänzer, Qirong Li, Yinzhe Wu 0001, Haosen Zhang, Kian Anvari Hamedani, Yuntong Lyu, Longyu Sun, Tianxing He, Lizhen Lan, Qiong Yao, Bingyu Xin, Dimitris N. Metaxas, Narges Razizadeh, Shahabedin Nabavi, George Yiasemis, Jonas Teuwen, Daniel B. Ennis, Zhihao Xue, Ruru Xu, Ilkay Öksüz, Donghang Lyu, Yanxin Huang, Xinrui Guo, Ruqian Hao, Jaykumar H. Patel, Guanke Cai, Binghua Chen, Sha Hua, Zhensen Chen, Qi Dou 0001, Xiahai Zhuang, Wenjia Bai, Harry Qin, He Wang 0016, Claudia Prieto, Michael Markl 0001, Alistair A. Young, Hao Li 0082, Xihong Hu, Lianming Wu, Xiaobo Qu 0001, Guang Yang 0006, Chengyan Wang |
IEEE Trans. Medical Imaging | 15 |
| 2026 | Cyclic Self-Supervised Diffusion for Ultra Low-Field to High-Field MRI SynthesisabstractSynthesizing high-quality images from low-field MRI holds significant potential. Low-field MRI is cheaper, more accessible, and safer, but suffers from low resolution and poor signal-to-noise ratio. This synthesis process can reduce reliance on costly acquisitions and expand data availability. However, synthesizing high-field MRI still suffers from a clinical fidelity gap. There is a need to preserve anatomical fidelity, enhance fine-grained structural details, and bridge domain gaps in image contrast. To address these issues, we propose a cyclic self-supervised diffusion (CSS-Diff) framework for high-field MRI synthesis from real low-field MRI data. Our core idea is to reformulate diffusion-based synthesis under a cycle-consistent constraint. It enforces anatomical preservation throughout the generative process rather than just relying on paired pixel-level supervision. The CSS-Diff framework further incorporates two novel processes. The slice-wise gap perception network aligns inter-slice inconsistencies via contrastive learning. The local structure correction network enhances local feature restoration through self-reconstruction of masked and perturbed patches. Extensive experiments on cross-field synthesis tasks demonstrate the effectiveness of our method, achieving state-of-the-art performance (e.g., $31.80~\pm ~2.70$ dB in PSNR, $0.943~\pm ~0.102$ in SSIM, and $0.0864~\pm ~0.0689$ in LPIPS). Beyond pixel-wise fidelity, our method also preserves fine-grained anatomical structures compared with the original low-field MRI (e.g., left cerebral white matter error drops from 12.1% to 2.1%, cortex from 4.2% to 3.7%). To conclude, our CSS-Diff can synthesize images that are both quantitatively reliable and anatomically consistent. The code is available at: https://github.com/ayanglab/CSS-Diff. Zhenxuan Zhang, Peiyuan Jing, Zi Wang 0005, Ula Briski, Coraline Beitone, Yinzhe Wu 0001, Fanwen Wang, Liutao Yang, Zhifan Gao, Zhaolin Chen, Kh Tohidul Islam, Guang Yang 0006, Peter J. Lally |
IEEE Trans. Medical Imaging | 7 |
| 2025 | Enhancing global sensitivity and uncertainty quantification in medical image reconstruction with Monte Carlo arbitrary-masked mambaabstractDeep learning has been extensively applied in medical image reconstruction, where Convolutional Neural Networks (CNNs) and Vision Transformers (ViTs) represent the predominant paradigms, each possessing distinct advantages and inherent limitations: CNNs exhibit linear complexity with local sensitivity, whereas ViTs demonstrate quadratic complexity with global sensitivity. The emerging Mamba has shown superiority in learning visual representation, which combines the advantages of linear scalability and global sensitivity. In this study, we introduce MambaMIR, an Arbitrary-Masked Mamba-based model with wavelet decomposition for joint medical image reconstruction and uncertainty estimation. A novel Arbitrary Scan Masking (ASM) mechanism "masks out" redundant information to introduce randomness for further uncertainty estimation. Compared to the commonly used Monte Carlo (MC) dropout, our proposed MC-ASM provides an uncertainty map without the need for hyperparameter tuning and mitigates the performance drop typically observed when applying dropout to low-level tasks. For further texture preservation and better perceptual quality, we employ the wavelet transformation into MambaMIR and explore its variant based on the Generative Adversarial Network, namely MambaMIR-GAN. Comprehensive experiments have been conducted for multiple representative medical image reconstruction tasks, demonstrating that the proposed MambaMIR and MambaMIR-GAN outperform other baseline and state-of-the-art methods in different reconstruction tasks, where MambaMIR achieves the best reconstruction fidelity and MambaMIR-GAN has the best perceptual quality. In addition, our MC-ASM provides uncertainty maps as an additional tool for clinicians, while mitigating the typical performance drop caused by the commonly used dropout. Liutao Yang, Fanwen Wang, Yinzhe Wu 0001, Yang Nan 0002, Weiwen Wu, Chengyan Wang, Kuangyu Shi, Angelica I. Avilés-Rivero, Carola-Bibiane Schönlieb, Daoqiang Zhang, Guang Yang 0006 |
Medical Image Anal. | 4 |
| 2025 | Enhanced DTCMR With Cascaded Alignment and Adaptive DiffusionabstractDiffusion tensor cardiovascular magnetic resonance (DTCMR) is the only non-invasive method for visualizing myocardial microstructure, but it is challenged by inconsistent breath-holds and imperfect cardiac triggering, causing in-plane shifts and through-plane warping with an inadequate tensor fitting. While rigid registration corrects in-plane shifts, deformable registration risks distorting the diffusion distribution, and selecting a reference frame among low SNR frames is challenging. Existing pairwise deep learning and iterative methods are unsuitable for DTCMR due to their inability to handle the drastic in-plane motion and disentangle the diffusion contrast distortion with through-plane motions on low SNR frames, which compromises the accuracy of clinical biomarker tensor estimation. Our study introduces a novel deep learning framework incorporating tensor information for groupwise deformable registration, effectively correcting intra-subject inter-frame motion. This framework features a cascaded registration branch for addressing in-plane and through-plane motions and a parallel branch for generating pseudo-frames with diffusion contrasts and template updates to guide registration with a refined loss function and denoising. We evaluated our method on four DTCMR-specific metrics using data from over 900 cases from 2012 to 2023. Our method outperformed three traditional and two deep learning-based methods, achieving reduced fitting errors, the lowest percentage of negative eigenvalues at 0.446%, the highest R2 of HA line profiles at 0.911, no negative Jacobian Determinant, and the shortest reference time of 0.06 seconds per case. In conclusion, our deep learning framework significantly improves DTCMR imaging by effectively correcting inter-frame motion and surpassing existing methods across multiple metrics, demonstrating substantial clinical potential. Fanwen Wang, Yihao Luo, Camila Munoz, Yaqing Luo, Yinzhe Wu 0001, Zohya Khalique, Maria Molto, Ramyah Rajakulasingam, Ranil De Silva, Dudley Pennell, Pedro F. Ferreira, Andrew D. Scott, Sonia Nielles-Vallespin, Guang Yang 0006 |
IEEE Trans. Medical Imaging | 7 |
| 2024 | Groupwise Deformable Registration of Diffusion Tensor Cardiovascular Magnetic Resonance: Disentangling Diffusion Contrast, Respiratory and Cardiac Motions
Fanwen Wang, Yihao Luo, Pedro F. Ferreira, Yaqing Luo, Yinzhe Wu 0001, Camila Munoz, Dudley Pennell, Andrew D. Scott, Sonia Nielles-Vallespin, Guang Yang 0006 |
MICCAI (2) | 7 |
| 2024 | Real-Time Non-Invasive Imaging and Detection of Spreading Depolarizations through EEG: An Ultra-Light Explainable Deep Learning ApproachabstractA core aim of neurocritical care is to prevent secondary brain injury. Spreading depolarizations (SDs) have been identified as an important independent cause of secondary brain injury. SDs are usually detected using invasive electrocorticography recorded at high sampling frequency. Recent pilot studies suggest a possible utility of scalp electrodes generated electroencephalogram (EEG) for non-invasive SD detection. However, noise and attenuation of EEG signals makes this detection task extremely challenging. Previous methods focus on detecting temporal power change of EEG over a fixed high-density map of scalp electrodes, which is not always clinically feasible. Having a specialized spectrogram as an input to the automatic SD detection model, this study is the first to transform SD identification problem from a detection task on a 1-D time-series wave to a task on a sequential 2-D rendered imaging. This study presented a novel ultra-light-weight multi-modal deep-learning network to fuse EEG spectrogram imaging and temporal power vectors to enhance SD identification accuracy over each single electrode, allowing flexible EEG map and paving the way for SD detection on ultra-low-density EEG with variable electrode positioning. Our proposed model has an ultra-fast processing speed (<0.3 sec). Compared to the conventional methods (2 hours), this is a huge advancement towards early SD detection and to facilitate instant brain injury prognosis. Seeing SDs with a new dimension - frequency on spectrograms, we demonstrated that such additional dimension could improve SD detection accuracy, providing preliminary evidence to support the hypothesis that SDs may show implicit features over the frequency profile. Yinzhe Wu 0001, Sharon Jewell, Xiaodan Xing, Yang Nan 0002, Anthony J. Strong, Guang Yang 0006, Martyn G. Boutelle |
IEEE J. Biomed. Health Informatics | 1 |
| 2023 | HDL: Hybrid Deep Learning for the Synthesis of Myocardial Velocity Maps in Digital Twins for Cardiac AnalysisabstractSynthetic digital twins based on medical data accelerate the acquisition, labelling and decision making procedure in digital healthcare. A core part of digital healthcare twins is model-based data synthesis, which permits the generation of realistic medical signals without requiring to cope with the modelling complexity of anatomical and biochemical phenomena producing them in reality. Unfortunately, algorithms for cardiac data synthesis have been so far scarcely studied in the literature. An important imaging modality in the cardiac examination is three-directional CINE multi-slice myocardial velocity mapping (3Dir MVM), which provides a quantitative assessment of cardiac motion in three orthogonal directions of the left ventricle. The long acquisition time and complex acquisition produce make it more urgent to produce synthetic digital twins of this imaging modality. In this study, we propose a hybrid deep learning (HDL) network, especially for synthetic 3Dir MVM data. Our algorithm is featured by a hybrid UNet and a Generative Adversarial Network with a foreground-background generation scheme. The experimental results show that from temporally down-sampled magnitude CINE images (six times), our proposed algorithm can still successfully synthesise high temporal resolution 3Dir MVM CMR data (PSNR=42.32) with precise left ventricle segmentation (DICE=0.92). These performance scores indicate that our proposed HDL algorithm can be implemented in real-world digital twins for myocardial velocity mapping data simulation. To the best of our knowledge, this work is the first one investigating digital twins of the 3Dir MVM CMR, which has shown great potential for improving the efficiency of clinical studies via synthesised cardiac data. Xiaodan Xing, Javier Del Ser, Yinzhe Wu 0001, Yang Li 0010, Jun Xia 0002, Lei Xu 0037, David N. Firmin, Peter Gatehouse, Guang Yang 0006 |
IEEE J. Biomed. Health Informatics | 3 |
| 2022 | CS2: A Controllable and Simultaneous Synthesizer of Images and Annotations with Minimal Human Intervention
Xiaodan Xing, Yang Nan 0002, Yinzhe Wu 0001, Chengjia Wang, Zhifan Gao, Simon Walsh, Guang Yang 0006 |
MICCAI (8) | 4 |
| 2022 | Swin transformer for fast MRIabstractMagnetic resonance imaging (MRI) is an important non-invasive clinical tool that can produce high-resolution and reproducible images. However, a long scanning time is required for high-quality MR images, which leads to exhaustion and discomfort of patients, inducing more artefacts due to voluntary movements of the patients and involuntary physiological movements. To accelerate the scanning process, methods by k-space undersampling and deep learning based reconstruction have been popularised. This work introduced SwinMR, a novel Swin transformer based method for fast MRI reconstruction. The whole network consisted of an input module (IM), a feature extraction module (FEM) and an output module (OM). The IM and OM were 2D convolutional layers and the FEM was composed of a cascaded of residual Swin transformer blocks (RSTBs) and 2D convolutional layers. The RSTB consisted of a series of Swin transformer layers (STLs). The shifted windows multi-head self-attention (W-MSA/SW-MSA) of STL was performed in shifted windows rather than the multi-head self-attention (MSA) of the original transformer in the whole image space. A novel multi-channel loss was proposed by using the sensitivity maps, which was proved to reserve more textures and details. We performed a series of comparative studies and ablation studies in the Calgary-Campinas public brain MR dataset and conducted a downstream segmentation experiment in the Multi-modal Brain Tumour Segmentation Challenge 2017 dataset. The results demonstrate our SwinMR achieved high-quality reconstruction compared with other benchmark methods, and it shows great robustness with different undersampling masks, under noise interruption and on different datasets. The code is publicly available at https://github.com/ayanglab/SwinMR. Yingying Fang, Yinzhe Wu 0001, Huanjun Wu, Zhifan Gao, Yang Li 0010, Javier Del Ser, Jun Xia 0002, Guang Yang 0006 |
Neurocomputing | 3 |