Demo Data from VLDB 2026 / reviewers in the wild / expert
Roberto Marabini
dblp:22/814
· DBLP profile ↗
12ranked-venue papers
3as first author
0since 2021 · last 2020
0000-0001-7876-1684ORCID · verified
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 4 · 1 first-authorApplied, interdisciplinary, general and emerging computing · 4Graphics, computer vision, multimedia, augmented reality and games · 3 · 2 first-authorSystems, architecture and hardware · 1
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Interdisciplinary, comprehensive, and emerging computing
5 papers |
Bioinformatics and computational biology · 100% | |
| Computer graphics and multimedia
1 paper |
Image and video processing · 100% |
Topics — the 9 heaviest of 9, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Bioinformatics and computational biology › structural biology
cryo-electron microscopy |
0.6 | 3 | 2019 | Validation of electron microscopy initial models via small angle X-ray scattering curves · Bioinform. 2019 A pattern matching approach to the automatic selection of particles from low-contrast electron micrographs · Bioinform. 2013 3-D reconstruction of 2-D crystals in real space · IEEE Trans. Image Process. 2004 |
Bioinformatics and computational biology
structural biology |
0.5 | 2 | 2020 | Automatic local resolution-based sharpening of cryo-EM maps · Bioinform. 2020 3-D reconstruction of 2-D crystals in real space · IEEE Trans. Image Process. 2004 |
Bioinformatics and computational biology › structural biology
small angle x-ray scattering analysis |
0.4 | 1 | 2019 | Validation of electron microscopy initial models via small angle X-ray scattering curves · Bioinform. 2019 |
Bioinformatics and computational biology › bioimage informatics
single-particle analysis |
0.2 | 1 | 2014 | Efficient initial volume determination from electron microscopy images of single particles · Bioinform. 2014 |
Bioinformatics and computational biology
structural bioinformatics |
0.2 | 1 | 2014 | Efficient initial volume determination from electron microscopy images of single particles · Bioinform. 2014 |
Bioinformatics and computational biology › bioimage informatics › single-particle analysis
particle picking |
0.2 | 1 | 2013 | A pattern matching approach to the automatic selection of particles from low-contrast electron micrographs · Bioinform. 2013 |
Bioinformatics and computational biology › structural biology › cryo-electron microscopy
3d reconstruction |
0.0 | 1 | 2004 | 3-D reconstruction of 2-D crystals in real space · IEEE Trans. Image Process. 2004 |
Image and video processing
image reconstruction |
0.0 | 1 | 2004 | 3-D reconstruction of 2-D crystals in real space · IEEE Trans. Image Process. 2004 |
Image and video processing › image reconstruction
iterative reconstruction |
0.0 | 1 | 2004 | 3-D reconstruction of 2-D crystals in real space · IEEE Trans. Image Process. 2004 |
Methods — techniques the papers use, named apart from their topics
wiener restoration · 0.4local resolution estimation · 0.4pseudo-atomic modeling · 0.4dimensionality reduction · 0.2RANSAC · 0.2support vector machine · 0.2shape feature extraction · 0.2real-space iterative reconstruction · 0.1projection constraints · 0.1
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2020 | Automatic local resolution-based sharpening of cryo-EM mapsabstractMOTIVATION: Recent technological advances and computational developments have allowed the reconstruction of Cryo-Electron Microscopy (cryo-EM) maps at near-atomic resolution. On a typical workflow and once the cryo-EM map has been calculated, a sharpening process is usually performed to enhance map visualization, a step that has proven very important in the key task of structural modeling. However, sharpening approaches, in general, neglects the local quality of the map, which is clearly suboptimal. RESULTS: Here, a new method for local sharpening of cryo-EM density maps is proposed. The algorithm, named LocalDeblur, is based on a local resolution-guided Wiener restoration approach of the original map. The method is fully automatic and, from the user point of view, virtually parameter-free, without requiring either a starting model or introducing any additional structure factor correction or boosting. Results clearly show a significant impact on map interpretability, greatly helping modeling. In particular, this local sharpening approach is especially suitable for maps that present a broad resolution range, as is often the case for membrane proteins or macromolecules with high flexibility, all of them otherwise very suitable and interesting specimens for cryo-EM. To our knowledge, and leaving out the use of local filters, it represents the first application of local resolution in cryo-EM sharpening. AVAILABILITY AND IMPLEMENTATION: The source code (LocalDeblur) can be found at https://github.com/I2PC/xmipp and can be run using Scipion (http://scipion.cnb.csic.es) (release numbers greater than or equal 1.2.1). SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online. Erney Ramírez-Aportela, Jose Luis Vilas, Alisa Glukhova, Roberto Melero, Pablo Conesa, Marta Martínez, David Maluenda, Javier Mota, Amaya Jiménez, Javier Vargas 0001, Roberto Marabini, Patrick M. Sexton, José María Carazo, Carlos Oscar Sánchez Sorzano |
Bioinform. | 11 |
| 2019 | Validation of electron microscopy initial models via small angle X-ray scattering curvesabstractMOTIVATION: Cryo electron microscopy (EM) is currently one of the main tools to reveal the structural information of biological macromolecules. The re-construction of three-dimensional (3D) maps is typically carried out following an iterative process that requires an initial estimation of the 3D map to be refined in subsequent steps. Therefore, its determination is key in the quality of the final results, and there are cases in which it is still an open issue in single particle analysis (SPA). Small angle X-ray scattering (SAXS) is a well-known technique applied to structural biology. It is useful from small nanostructures up to macromolecular ensembles for its ability to obtain low resolution information of the biological sample measuring its X-ray scattering curve. These curves, together with further analysis, are able to yield information on the sizes, shapes and structures of the analyzed particles. RESULTS: In this paper, we show how the low resolution structural information revealed by SAXS is very useful for the validation of EM initial 3D models in SPA, helping the following refinement process to obtain more accurate 3D structures. For this purpose, we approximate the initial map by pseudo-atoms and predict the SAXS curve expected for this pseudo-atomic structure. The match between the predicted and experimental SAXS curves is considered as a good sign of the correctness of the EM initial map. AVAILABILITY AND IMPLEMENTATION: The algorithm is freely available as part of the Scipion 1.2 software at http://scipion.i2pc.es/. Amaya Jiménez, Slavica Jonic, Tomás Majtner, Joaquín Otón, Jose Luis Vilas, David Maluenda, Javier Mota, Erney Ramírez-Aportela, Marta Martínez, Yaiza Rancel, Joan Segura, Rubén Sánchez García, Roberto Melero, Laura del Cano, Pablo Conesa, Lars Skjærven, Roberto Marabini, José María Carazo, Carlos Oscar Sánchez Sorzano |
Bioinform. | 17 |
| 2014 | An image processing approach to the simulation of electron microscopy volumes of atomic structuresabstractThe goal of this paper is to construct accurate three-dimensional models from atomic structures that can be compared to Electron Microscopy volumes. They, in their turn, can be used to solve fitting and docking problems as well as to generate ground-truth models for the development of image processing algorithms. We use Electron Atomic Scattering Factor (EASF) along with a careful filter design to greatly accelerate the current use of these functions and strongly reduce computer memory requirements. We show that our method is 3 orders of magnitude faster than existing implementations of EASFs in Fourier space as well as more accurate than their standard implementations. The algorithm is freely available in the software package Xmipp (http://xmipp.cnb.csic.es) [1]. Carlos Oscar Sánchez Sorzano, Javier Vargas 0001, Joaquín Otón, Vahid Abrishami, José Miguel de la Rosa-Trevín, S. del Riego, A. Fernandez-Alderete, C. Martinez-Rey, Roberto Marabini, José María Carazo |
ICIP | 9 |
| 2014 | Efficient initial volume determination from electron microscopy images of single particlesabstractMOTIVATION: Structural information of macromolecular complexes provides key insights into the way they carry out their biological functions. The reconstruction process leading to the final 3D map requires an approximate initial model. Generation of an initial model is still an open and challenging problem in single-particle analysis. RESULTS: We present a fast and efficient approach to obtain a reliable, low-resolution estimation of the 3D structure of a macromolecule, without any a priori knowledge, addressing the well-known issue of initial volume estimation in the field of single-particle analysis. The input of the algorithm is a set of class average images obtained from individual projections of a biological object at random and unknown orientations by transmission electron microscopy micrographs. The proposed method is based on an initial non-lineal dimensionality reduction approach, which allows to automatically selecting representative small sets of class average images capturing the most of the structural information of the particle under study. These reduced sets are then used to generate volumes from random orientation assignments. The best volume is determined from these guesses using a random sample consensus (RANSAC) approach. We have tested our proposed algorithm, which we will term 3D-RANSAC, with simulated and experimental data, obtaining satisfactory results under the low signal-to-noise conditions typical of cryo-electron microscopy. AVAILABILITY: The algorithm is freely available as part of the Xmipp 3.1 package [http://xmipp.cnb.csic.es]. CONTACT: [email protected] SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online. Javier Vargas 0001, Ana-Lucia Álvarez-Cabrera, Roberto Marabini, José María Carazo, Carlos Oscar Sánchez Sorzano |
Bioinform. | 3 |
| 2013 | A pattern matching approach to the automatic selection of particles from low-contrast electron micrographsabstractMOTIVATION: Structural information of macromolecular complexes provides key insights into the way they carry out their biological functions. Achieving high-resolution structural details with electron microscopy requires the identification of a large number (up to hundreds of thousands) of single particles from electron micrographs, which is a laborious task if it has to be manually done and constitutes a hurdle towards high-throughput. Automatic particle selection in micrographs is far from being settled and new and more robust algorithms are required to reduce the number of false positives and false negatives. RESULTS: In this article, we introduce an automatic particle picker that learns from the user the kind of particles he is interested in. Particle candidates are quickly and robustly classified as particles or non-particles. A number of new discriminative shape-related features as well as some statistical description of the image grey intensities are used to train two support vector machine classifiers. Experimental results demonstrate that the proposed method: (i) has a considerably low computational complexity and (ii) provides results better or comparable with previously reported methods at a fraction of their computing time. AVAILABILITY: The algorithm is fully implemented in the open-source Xmipp package and downloadable from http://xmipp.cnb.csic.es. Vahid Abrishami, Airen Zaldívar-Peraza, José Miguel de la Rosa-Trevín, Javier Vargas 0001, Joaquín Otón, Roberto Marabini, Yoel Shkolnisky, José María Carazo, Carlos Oscar Sánchez Sorzano |
Bioinform. | 6 |
| 2008 | Volumetric restrictions in single particle 3DEM reconstruction
Carlos Oscar Sánchez Sorzano, Javier A. Velázquez-Muriel, Roberto Marabini, Gabor T. Herman, José María Carazo |
Pattern Recognit. | 3 |
| 2007 | Electron tomography of complex biological specimens on the Grid
José-Jesús Fernández, Inmaculada García, José María Carazo, Roberto Marabini |
Future Gener. Comput. Syst. | 4 |
| 2005 | Multiobjective algorithm parameter optimization using multivariate statistics in three-dimensional electron microscopy reconstruction
Carlos Oscar Sánchez Sorzano, Roberto Marabini, Gabor T. Herman, José María Carazo |
Pattern Recognit. | 2 |
| 2004 | 3-D reconstruction of 2-D crystals in real spaceabstractA new algorithm for three-dimensional reconstruction of two-dimensional crystals from projections is presented, and its applicability to biological macromolecules imaged using transmission electron microscopy (TEM) is investigated. Its main departures from the traditional approach is that it works in real space, rather than in Fourier space, and it is iterative. This has the advantage of making it convenient to introduce additional constraints (such as the support of the function to be reconstructed, which may be known from alternative measurements) and has the potential of more accurately modeling the TEM image formation process. Phantom experiments indicate the superiority of the new approach even without the introduction of constraints in addition to the projection data. Roberto Marabini, Carlos Oscar Sánchez Sorzano, Samuel Matej, José-Jesús Fernández, José María Carazo, Gabor T. Herman |
IEEE Trans. Image Process. | 1 |
| 1998 | Automatic Classification of Biological Particles from Electron-microscopy Images Using Conventional and Genetic-algorithm Optimized Learning Vector Quantization
Juan Julián Merelo Guervós, Alberto Prieto, Federico Morán, Roberto Marabini, José María Carazo |
Neural Process. Lett. | 4 |
| 1996 | On a new computationally fast image invariant based on bispectral projections
Roberto Marabini, José María Carazo |
Pattern Recognit. Lett. | 1 |
| 1994 | Practical issues on invariant image averaging using the Bispectrum
Roberto Marabini, José María Carazo |
Signal Process. | 1 |