Demo Data from VLDB 2026 / reviewers in the wild / expert
Chim Lee Cheung
dblp:221/4385
· DBLP profile ↗
2ranked-venue papers
1as first author
2since 2021 · last 2024
0000-0003-4737-6120ORCID · reported
Domains — the database's venue-derived domains; a paper can count in several
Applied, interdisciplinary, general and emerging computing · 2 · 1 first-author · 2 since 2021
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Interdisciplinary, comprehensive, and emerging computing
1 paper |
Medical and health informatics · 100% | |
| Artificial intelligence
1 paper |
Robot manipulation · 100% |
Topics — the 1 heaviest of 3, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Medical and health informatics
computer-assisted intervention |
0.6 | 1 | 2022 | Shape Tracking and Feedback Control of Cardiac Catheter Using MRI-Guided Robotic Platform - Validation With Pulmonary Vein Isolation Simulator in MRI · IEEE Trans. Robotics 2022 |
Methods — techniques the papers use, named apart from their topics
tracking coils · 1.1learning-based modeling · 1.1fiber bragg grating sensing · 1.1
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2024 | Omnidirectional Monolithic Marker for Intra-Operative MR-Based Positional Sensing in Closed MRIabstractWe present a design of an inductively coupled radio frequency (ICRF) marker for magnetic resonance (MR)-based positional tracking, enabling the robust increase of tracking signal at all scanning orientations in quadrature-excited closed MR imaging (MRI). The marker employs three curved resonant circuits fully covering a cylindrical surface that encloses the signal source. Each resonant circuit is a planar spiral inductor with parallel plate capacitors fabricated monolithically on flexible printed circuit board (FPC) and bent to achieve the curved structure. Size of the constructed marker is Ø3-mm ×5 -mm with quality factor > 22, and its tracking performance was validated with 1.5 T MRI scanner. As result, the marker remains as a high positive contrast spot under 360° rotations in 3 axes. The marker can be accurately localized with a maximum error of 0.56 mm under a displacement of 56 mm from the isocenter, along with an inherent standard deviation of 0.1-mm. Accrediting to the high image contrast, the presented marker enables automatic and real-time tracking in 3D without dependency on its orientation with respect to the MRI scanner receive coil. In combination with its small form-factor, the presented marker would facilitate robust and wireless MR-based tracking for intervention and clinical diagnosis. This method targets applications that can involve rotational changes in all axes (X-Y-Z). Chim Lee Cheung, Ge Fang, Justin D. L. Ho, Liyuan Liang, Kel Vin Tan, Fa-Hsuan Lin, Hing-Chiu Chang, Ka-Wai Kwok |
IEEE Trans. Medical Imaging | 1 |
| 2022 | Shape Tracking and Feedback Control of Cardiac Catheter Using MRI-Guided Robotic Platform - Validation With Pulmonary Vein Isolation Simulator in MRIabstractCardiac electrophysiology is an effective treatment for atrial fibrillation, in which a long, steerable catheter is inserted into the heart chamber to conduct radio frequency ablation. Magnetic resonance imaging (MRI) can provide enhanced intraoperative monitoring of the ablation progress as well as the localization of catheter position. However, accurate and real-time tracking of the catheter shape and its efficient manipulation under MRI remains challenging. In this article, we designed a shape tracking system that integrates a multicore fiber Bragg grating (FBG) fiber and tracking coils with a standard cardiac catheter. Both the shape and positional tracking of the bendable section could be achieved. A learning-based modeling method is developed for cardiac catheters, which uses FBG-reconstructed three-dimensional curvatures for model initialization. The proposed modeling method was implemented on an MRI-guided robotic platform to achieve feedback control of a cardiac catheter. The shape tracking performance was experimentally verified, demonstrating 2.33° average error for each sensing segment and 1.53 mm positional accuracy at the catheter tip. The feedback control performance was tested by autonomous targeting and path following (average deviation of 0.62 mm) tasks. The overall performance of the integrated robotic system was validated by a pulmonary vein isolation simulator withex-vivotissue ablation, which employed a left atrial phantom with pulsatile liquid flow. Catheter tracking and feedback control tests were conducted in an MRI scanner, demonstrating the capability of the proposed system under MRI. Ziyang Dong, Ge Fang, Zhuoliang He, Justin D. L. Ho, Chim Lee Cheung, Wai Lun Tang, Xiaochen Xie, Liyuan Liang, Hing-Chiu Chang, Chi Keong Ching, Ka-Wai Kwok |
IEEE Trans. Robotics | 6 |