Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Peicheng Du

dblp:24/4475 · DBLP profile ↗
← Back
2ranked-venue papers
2as first author
0since 2021 · last 2008
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 2 · 2 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
2 papers
Bioinformatics and computational biology · 85% Computational science and engineering · 15%

Topics — the 6 heaviest of 6, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Bioinformatics and computational biology
proteomics
0.222008
A noise model for mass spectrometry based proteomics · Bioinform. 2008
Data reduction of isotope-resolved LC-MS spectra · Bioinform. 2007
Bioinformatics and computational biology › proteomics › peptide analysis
peptide detection
0.122008
Data reduction of isotope-resolved LC-MS spectra · Bioinform. 2007
A noise model for mass spectrometry based proteomics · Bioinform. 2008
Bioinformatics and computational biology › proteomics
mass spectrometry data analysis
0.112008
A noise model for mass spectrometry based proteomics · Bioinform. 2008
Computational science and engineering
noise modeling
0.112008
A noise model for mass spectrometry based proteomics · Bioinform. 2008
Bioinformatics and computational biology › metabolomics
LC-MS data analysis
0.112007
Data reduction of isotope-resolved LC-MS spectra · Bioinform. 2007
Bioinformatics and computational biology › epigenomics › ChIP-seq analysis
peak detection
0.112007
Data reduction of isotope-resolved LC-MS spectra · Bioinform. 2007

Methods — techniques the papers use, named apart from their topics

poisson model · 0.1multinomial model · 0.1detector dead-time correction · 0.1variable selection · 0.1iterative peak-picking · 0.1deconvolution · 0.1
YearPublicationVenuePosition
2008 A noise model for mass spectrometry based proteomics
abstract
MOTIVATION: Mass spectrometry data are subjected to considerable noise. Good noise models are required for proper detection and quantification of peptides. We have characterized noise in both quadrupole time-of-flight (Q-TOF) and ion trap data, and have constructed models for the noise. RESULTS: We find that the noise in Q-TOF data from Applied Biosystems QSTAR fits well to a combination of multinomial and Poisson model with detector dead-time correction. In comparison, ion trap noise from Agilent MSD-Trap-SL is larger than the Q-TOF noise and is proportional to Poisson noise. We then demonstrate that the noise model can be used to improve deisotoping for peptide detection, by estimating appropriate cutoffs of the goodness of fit parameter at prescribed error rates. The noise models also have implications in noise reduction, retention time alignment and significance testing for biomarker discovery.
Peicheng Du, Gustavo Stolovitzky, Peter Horvatovich, Rainer Bischoff 0003, Jihyeon Lim, Frank Suits
Bioinform.1
2007 Data reduction of isotope-resolved LC-MS spectra
abstract
MOTIVATION: Data reduction of liquid chromatography-mass spectrometry (LC-MS) spectra can be a challenge due to the inherent complexity of biological samples, noise and non-flat baseline. We present a new algorithm, LCMS-2D, for reliable data reduction of LC-MS proteomics data. RESULTS: LCMS-2D can reliably reduce LC-MS spectra with multiple scans to a list of elution peaks, and subsequently to a list of peptide masses. It is capable of noise removal, and deconvoluting peaks that overlap in m/z, in retention time, or both, by using a novel iterative peak-picking step, a 'rescue' step, and a modified variable selection method. LCMS-2D performs well with three sets of annotated LC-MS spectra, yielding results that are better than those from PepList, msInspect and the vendor software BioAnalyst. AVAILABILITY: The software LCMS-2D is available under the GNU general public license from http://www.bioc.aecom.yu.edu/labs/angellab/as a standalone C program running on LINUX.
Peicheng Du, Rajagopalan Sudha, Michael B. Prystowsky, Ruth Hogue Angeletti
Bioinform.1