Sung-Liang Chen

dblp:245/0291 · DBLP profile ↗
← Back
6ranked-venue papers
0as first author
6since 2021 · last 2026
0000-0002-0572-5110ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 5 · 5 since 2021Artificial intelligence and machine learning · 1 · 1 since 2021Systems, architecture and hardware · 1 · 1 since 2021
YearPublicationVenuePosition
2026 Beyond benchmarks of IUGC: Rethinking requirements of deep learning method for intrapartum ultrasound biometry from fetal ultrasound videos
Jieyun Bai, Yitong Tang, Zhuonan Liang, Jianan Fan, Lisa Mcguire, Jillian Clarke, Tom Weidong Cai, Jacqueline Spurway, Yubo Tang, Shiye Wang, Wenda Shen, Wangwang Yu, Philippe Zhang, Weili Jiang, Salem Muhsin Ali Binqahal Al Nasim, Arsen Abzhanov, Numan Saeed, Mohammad Yaqub, Zunhui Xia, Hongxing Li 0001, Libin Lan, Jayroop Ramesh, Valentin Bacher, Mark Eid, Hoda Kalabizadeh, Christian Rupprecht 0001, Ana I. L. Namburete, Pak-Hei Yeung, Madeleine K. Wyburd, Nicola K. Dinsdale, Assanali Serikbey, Jiankai Li, Sung-Liang Chen, Zicheng Hu, Nana Liu, Yian Deng, Wenfeng Zhang, Mai Tuyet Nhi, Gregor Koehler, Rapheal Stock, Klaus H. Maier-Hein, Marawan Elbatel, Xiaomeng Li 0001, Saad Slimani, Victor M. Campello, Benard Ohene Botwe, Isaac Khobo, Zhenyan Han, Hongying Hou, Di Qiu, Gongning Luo, Dong Ni 0001, Yaosheng Lu, Karim Lekadir, Shuo Li 0001
Medical Image Anal.37
2026 Automatic Multi-Task Segmentation and Vulnerability Assessment of Carotid Plaque on Contrast-Enhanced Ultrasound Images and Videos via Deep Learning
abstract
Intraplaque neovascularization (IPN) within carotid plaque is a crucial indicator of plaque vulnerability. Contrast-enhanced ultrasound (CEUS) is a valuable tool for assessing IPN by evaluating the location and quantity of microbubbles within the carotid plaque. However, this task is typically performed by experienced radiologists. Here we propose a deep learning-based multi-task model for the automatic segmentation and IPN grade classification of carotid plaque on CEUS images and videos. We also compare the performance of our model with that of radiologists. To simulate the clinical practice of radiologists, who often use CEUS videos with dynamic imaging to track microbubble flow and identify IPN, we develop a workflow for plaque vulnerability assessment using CEUS videos. Our multi-task model outperformed individually trained segmentation and classification models, achieving superior performance in IPN grade classification based on CEUS images. Specifically, our model achieved a high segmentation Dice coefficient of 84.64% and a high classification accuracy of 81.67% . Moreover, our model surpassed the performance of junior and medium-level radiologists, providing more accurate IPN grading of carotid plaque on CEUS images. For CEUS videos, our model achieved a classification accuracy of 80.00% in IPN grading. Overall, our multi-task model demonstrates great performance in the automatic, accurate, objective, and efficient IPN grading in both CEUS images and videos. This work holds significant promise for enhancing the clinical diagnosis of plaque vulnerability associated with IPN in CEUS evaluations.
Bokai Hu, Caixia Jia, Xiangjiang Tang, Da He, Luni Zhang, Shiyao Gu, Jitong Zhang, Sung-Liang Chen
IEEE J. Biomed. Health Informatics12
2025 FPM-R2Net: Fused Photoacoustic and operating Microscopic imaging with cross-modality Representation and Registration Network
Yuxuan Liu 0013, Yating Luo, Sung-Liang Chen, Yao Guo 0002, Guang-Zhong Yang
Medical Image Anal.4
2024 Fast Photoacoustic Microscopy with Robot Controlled Microtrajectory Optimization
abstract
Photoacoustic Microscopy (PAM) is a relatively new imaging modality in biomedicine. However, point-by-point raster scanning in PAM suffers from low imaging speed. Sparse sampling has been studied in recent years and with the development of deep learning algorithms, extensive efforts have been devoted to sparse image reconstruction while little attention has been paid to sparse sampling trajectory design required for actual implementation. The use of real-time adaptive robotically controlled sampling with micro-scale accuracy with due consideration of physical constraints can pave the way for using PAM for robot-assisted microsurgery. This work proposes a fast PAM scheme with robot-controlled microtrajectory optimization. The proposed method is adaptive to imaging details of different regions of interest (ROI) and detailed experiments have been conducted on both simulation and in-vivo settings. Results show that our proposed method can achieve faster scanning speed than traditional raster scanning and improved image quality in ROI than the standard spiral trajectory, which demonstrates the effectiveness of our proposed method and its potential to be deployed in other point-by-point scanning systems.
Yating Luo, Yuxuan Liu 0013, Sung-Liang Chen, Yao Guo 0002, Guang-Zhong Yang
ICRA4
2023 De-Noising of Photoacoustic Microscopy Images by Attentive Generative Adversarial Network
abstract
As a hybrid imaging technology, photoacoustic microscopy (PAM) imaging suffers from noise due to the maximum permissible exposure of laser intensity, attenuation of ultrasound in the tissue, and the inherent noise of the transducer. De-noising is an image processing method to reduce noise, and PAM image quality can be recovered. However, previous de-noising techniques usually heavily rely on manually selected parameters, resulting in unsatisfactory and slow de-noising performance for different noisy images, which greatly hinders practical and clinical applications. In this work, we propose a deep learning-based method to remove noise from PAM images without manual selection of settings for different noisy images. An attention enhanced generative adversarial network is used to extract image features and adaptively remove various levels of Gaussian, Poisson, and Rayleigh noise. The proposed method is demonstrated on both synthetic and real datasets, including phantom (leaf veins) and in vivo (mouse ear blood vessels and zebrafish pigment) experiments. In the in vivo experiments using synthetic datasets, our method achieves the improvement of 6.53 dB and 0.26 in peak signal-to-noise ratio and structural similarity metrics, respectively. The results show that compared with previous PAM de-noising methods, our method exhibits good performance in recovering images qualitatively and quantitatively. In addition, the de-noising processing speed of 0.016 s is achieved for an image with 256×256 pixels, which has the potential for real-time applications. Our approach is effective and practical for the de-noising of PAM images.
Da He, Xiaoyu Shang, Xingye Tang, Jiajia Luo, Sung-Liang Chen
IEEE Trans. Medical Imaging6
2023 Miniature Probe for Optomechanical Focus-Adjustable Optical-Resolution Photoacoustic Endoscopy
abstract
Photoacoustic microscopy (PAM) is a promising imaging modality because it is able to reveal optical absorption contrast in high resolution on the order of a micrometer. It can be applied in an endoscopic approach by implementing PAM into a miniature probe, termed photoacoustic endoscopy (PAE). Here we develop a miniature focus-adjustable PAE (FA-PAE) probe characterized by both high resolution (in micrometers) and large depth of focus (DOF) via a novel optomechanical design for focus adjustment. To realize high resolution and large DOF in a miniature probe, a 2-mm plano-convex lens is specially adopted, and the mechanical translation of a single-mode fiber is meticulously designed to allow the use of multi-focus image fusion (MIF) for extended DOF. Compared with existing PAE probes, our FA-PAE probe achieves high resolution of [Formula: see text] within unprecedentedly large DOF of 3.2 mm, more than 27 times the DOF of the probe without performing focus adjustment for MIF. The superior performance is first demonstrated by imaging both phantoms and animals including mice and zebrafish in vivo by linear scanning. Further, in vivo endoscopic imaging of a rat's rectum by rotary scanning of the probe is conducted to showcase the capability of adjustable focus. Our work opens new perspectives for PAE biomedical applications.
Zhendong Guo, Da He, Wenzhao Yang, Zhanhong Ye, Weihao Shao, Lili Jing, Sung-Liang Chen
IEEE Trans. Medical Imaging9