Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Zhuoliang He

dblp:263/9401 · DBLP profile ↗
← Back
1ranked-venue papers
0as first author
1since 2021 · last 2022
—ORCID · unresolved

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 1 · 1 since 2021

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%
Artificial intelligence
1 paper
Robot manipulation · 100%

Topics — the 1 heaviest of 3, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics
computer-assisted intervention
0.612022
Shape Tracking and Feedback Control of Cardiac Catheter Using MRI-Guided Robotic Platform - Validation With Pulmonary Vein Isolation Simulator in MRI · IEEE Trans. Robotics 2022

Methods — techniques the papers use, named apart from their topics

tracking coils · 1.1learning-based modeling · 1.1fiber bragg grating sensing · 1.1
YearPublicationVenuePosition
2022 Shape Tracking and Feedback Control of Cardiac Catheter Using MRI-Guided Robotic Platform - Validation With Pulmonary Vein Isolation Simulator in MRI
abstract
Cardiac electrophysiology is an effective treatment for atrial fibrillation, in which a long, steerable catheter is inserted into the heart chamber to conduct radio frequency ablation. Magnetic resonance imaging (MRI) can provide enhanced intraoperative monitoring of the ablation progress as well as the localization of catheter position. However, accurate and real-time tracking of the catheter shape and its efficient manipulation under MRI remains challenging. In this article, we designed a shape tracking system that integrates a multicore fiber Bragg grating (FBG) fiber and tracking coils with a standard cardiac catheter. Both the shape and positional tracking of the bendable section could be achieved. A learning-based modeling method is developed for cardiac catheters, which uses FBG-reconstructed three-dimensional curvatures for model initialization. The proposed modeling method was implemented on an MRI-guided robotic platform to achieve feedback control of a cardiac catheter. The shape tracking performance was experimentally verified, demonstrating 2.33° average error for each sensing segment and 1.53 mm positional accuracy at the catheter tip. The feedback control performance was tested by autonomous targeting and path following (average deviation of 0.62 mm) tasks. The overall performance of the integrated robotic system was validated by a pulmonary vein isolation simulator withex-vivotissue ablation, which employed a left atrial phantom with pulsatile liquid flow. Catheter tracking and feedback control tests were conducted in an MRI scanner, demonstrating the capability of the proposed system under MRI.
Ziyang Dong, Ge Fang, Zhuoliang He, Justin D. L. Ho, Chim Lee Cheung, Wai Lun Tang, Xiaochen Xie, Liyuan Liang, Hing-Chiu Chang, Chi Keong Ching, Ka-Wai Kwok
IEEE Trans. Robotics4