Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Ryo Mochizuki

dblp:27/6332 · DBLP profile ↗
← Back
7ranked-venue papers
2as first author
0since 2021 · last 2012
—ORCID · conflict

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 5 · 1 first-authorGraphics, computer vision, multimedia, augmented reality and games · 5 · 2 first-authorSystems, architecture and hardware · 2Applied, interdisciplinary, general and emerging computing · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
2 papers
Video understanding and tracking · 72% 3D vision · 14% Robot manipulation · 14%
Interdisciplinary, comprehensive, and emerging computing
2 papers
Medical and health informatics · 100%

Topics — the 9 heaviest of 9, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Computer vision › Video understanding and tracking › object tracking
contour tracking
0.112012
Full state visual forceps tracking under a microscope using projective contour models · ICRA 2012
Computer vision › Video understanding and tracking › object tracking
model-based tracking
0.112012
Full state visual forceps tracking under a microscope using projective contour models · ICRA 2012
Computer vision › Video understanding and tracking
object tracking
0.112012
Full state visual forceps tracking under a microscope using projective contour models · ICRA 2012
Medical and health informatics
surgical assistance
0.112012
Full state visual forceps tracking under a microscope using projective contour models · ICRA 2012
Medical and health informatics › computer-assisted surgery
surgical tool tracking
0.112012
Full state visual forceps tracking under a microscope using projective contour models · ICRA 2012
Robotics › Robot manipulation
grasping, dexterous and mobile manipulation
0.112008
Master manipulator with higher operability designed for micro neuro surgical system · ICRA 2008
Computer vision › 3D vision
3d reconstruction
0.012012
Full state visual forceps tracking under a microscope using projective contour models · ICRA 2012
Computer vision › 3D vision › object pose estimation
CAD model pose estimation
0.012012
Full state visual forceps tracking under a microscope using projective contour models · ICRA 2012
Medical and health informatics
surgical robotics
0.012008
Master manipulator with higher operability designed for micro neuro surgical system · ICRA 2008

Methods — techniques the papers use, named apart from their topics

projective contour modeling · 0.3particle filtering · 0.3edge distance transformation · 0.3motion analysis · 0.2manipulator control · 0.2
YearPublicationVenuePosition
2012 Full state visual forceps tracking under a microscope using projective contour models
abstract
Forceps tracking is an important element of high-level surgical assistance such as visual servoing and surgical motion analysis. In many computer vision algorithms, artificial markers are used to enable robust tracking; however, markerless tracking methods are more appropriate in surgical applications due to their sterilizability. This paper describes a robust, efficient tracking algorithm capable of estimating the full state parameters of a robotic surgical instrument on the basis of projective contour modeling using a 3-D CAD model of the forceps. Thus, the proposed method does not require any artificial markers. The likelihood of the contour model was measured using edge distance transformation to evaluate the similarity of the projected CAD model to the microscopic image, followed by particle filtering to estimate the full state of the forceps. Experimental results in simulated surgical environments indicate that the proposed method is robust and time-efficient, and fulfills real-time processing requirements.
Young Min Baek, Shinichi Tanaka, Kanako Harada, Naohiko Sugita, Akio Morita, Shigeo Sora, Ryo Mochizuki, Mamoru Mitsuishi
ICRA7
2008 Master manipulator with higher operability designed for micro neuro surgical system
abstract
The master and slave surgical assistant systems have been studied actively. However, regarding the master system, the manipulator should be designed for each surgical field because the target workspace and precision are different. Furthermore, operability is important for safety reasons. Therefore, the authors analyzed the motion of surgeon first and then developed a master manipulator suitable for the operation of micro neuro surgery. Some experiments were conducted to evaluate the control method and show the effectiveness of the proposed manipulator control method.
Hiroki Takahashi, Tsubasa Yonemura, Naohiko Sugita, Mamoru Mitsuishi, Shigeo Sora, Akio Morita, Ryo Mochizuki
ICRA7
2004 A low-band spectrum envelope modeling for high quality pitch modification
abstract
A low-band spectrum envelope reconstruction method was tested to see if it could improve the sound quality of speech modified by the PSOLA (pitch synchronous overlap add) method. In the conventional TD (time domain)-PSOLA method, the spectrum envelope extracted using a Hanning window with a two-pitch-period length had no reliable information in the band of frequencies lower than original F/sub 0/. This problem causes the sound degradation of the F/sub 0/ modified speech. In the proposed method, the low-band spectrum envelope was properly modified according to the F/sub 0/ modification rate. The amplitude of the F/sub 0/ harmonic components in the low-band was reproduced based on the spectral tilt of the spectrum envelope. Subjective listening test results suggest this proposed method yields better sound quality than the conventional TD-PSOLA method when the downward modification rate exceeds 0.4 octave.
Ryo Mochizuki, Tetsunori Kobayashi
ICASSP (1)1
2004 Micro-Neurosurgical System in the Deep Surgical Field
Daisuke Asai, Surman Katopo, Jumpei Arata, Shin'ichi Warisawa, Mamoru Mitsuishi, Akio Morita, Shigeo Sora, Takaaki Kirino, Ryo Mochizuki
MICCAI (2)9
2000 Improving the naturalness of synthetic speech by utilizing the prosody of natural speech
Toshimitsu Minowa, Ryo Mochizuki, Hirofumi Nishimura
INTERSPEECH2
1998 A study on the natural-sounding Japanese phonetic word synthesis by using the VCV-balanced word database that consists of the words uttered forcibly in two types of pitch accent
abstract
In order to synthesize natural-sounding Japanese phonetic words, a novel VCV-concatenation synthesis with an advanced word database is proposed. The word database consists of VCVbalanced phonetic words which are uttered forcibly in type-0 and type-1 pitch accents. The advantage of using the advanced word database is that a variety of VCV-segments with the same phonetic chains and the different pitch patterns could be collected efficiently at the same time. The following pitch modification techniques are used to achieve the sound quality: (1) The optimal VCV-segment set which minimizes the pitch modification rate is selected. (2) Pitch waveforms are extracted by referring to excitation points. (3) Wavelengths of pitch waveforms are adjusted depending on the pitch modification rates. (4) Natural prosody in the VCV-segments in the database is effectively used. Superiority of the proposed database is ensured by means of the pitch pattern matching measurement and the subjective quality evaluation.
Ryo Mochizuki, Yasuhiko Arai, Takashi Honda
ICSLP1
1996 An excitation synchronous pitch waveform extraction method and its application to the VCV-concatenation synthesis of Japanese spoken words
Yasuhiko Arai, Ryo Mochizuki, Hirofumi Nishimura, Takashi Honda
ICSLP2