Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Domenico Tibone

dblp:272/2150 · DBLP profile ↗
← Back
1ranked-venue papers
0as first author
0since 2021 · last 1978
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Computer networks · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Computer networks
1 paper
Optical networks · 100%

Topics — the 3 heaviest of 4, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Optical networks
field trials
0.011978
COS 2 Experiment in Turin: Field Test on an Optical Cable in Ducts · IEEE Trans. Commun. 1978
Optical networks
optical fiber cable
0.011978
COS 2 Experiment in Turin: Field Test on an Optical Cable in Ducts · IEEE Trans. Commun. 1978
Optical networks
optical transmission
0.011978
COS 2 Experiment in Turin: Field Test on an Optical Cable in Ducts · IEEE Trans. Commun. 1978

Methods — techniques the papers use, named apart from their topics

splice technique · 0.0field measurement · 0.0
YearPublicationVenuePosition
1978 COS 2 Experiment in Turin: Field Test on an Optical Cable in Ducts
abstract
"COS 2" is the second Italian field trial with an optical cable. In this experiment about 5 km of optical cable were installed in normal telephone ducts of the Turin local network between two telephone exchanges. The cable has a capacity of 8 fibers, but, for cost reasons, in 4 of the 5 km of cable only 3 fibers were inserted. An installation procedure was developed, allowing the independent laying of several cables in one duct; it was possible to pull up to 1 km of optical cable in order to minimize the number of splices. A special splice (Springroove®splice) and splicing technique, not requiring the use of a microscope or other intricate tools, were employed. Field measurements of transmission characteristics (attenuation and bandwidth) were performed by means of specially designed measurement equipment. An experimental 140 Mbit/s system was tested on a link about 9 km long (without intermediate repeaters) obtained using this cable.
Giuseppe Cocito, Sergio Longoni, Leonardo Michetti, Luciano Silvestri, Domenico Tibone, Federico Tosco
IEEE Trans. Commun.6