Demo Data from VLDB 2026 / reviewers in the wild / expert
Ross J. Cortino
dblp:324/6199
· DBLP profile ↗
2ranked-venue papers
1as first author
2since 2021 · last 2023
0000-0002-7844-2314ORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 2 · 1 first-author · 2 since 2021Systems, architecture and hardware · 2 · 1 first-author · 2 since 2021
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Artificial intelligence
1 paper |
Motion planning and robot control · 100% | |
| Interdisciplinary, comprehensive, and emerging computing
1 paper |
Medical and health informatics · 100% |
Topics — the 2 heaviest of 2, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Robotics › Motion planning and robot control
robot control |
0.6 | 1 | 2022 | Stair Ascent Phase-Variable Control of a Powered Knee-Ankle Prosthesis · ICRA 2022 |
Medical and health informatics
assistive technology |
0.2 | 1 | 2022 | Stair Ascent Phase-Variable Control of a Powered Knee-Ankle Prosthesis · ICRA 2022 |
Methods — techniques the papers use, named apart from their topics
reference kinematics · 1.1phase variable · 1.1
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2023 | Improving Amputee Endurance Over Activities of Daily Living with a Robotic Knee-Ankle Prosthesis: A Case StudyabstractRobotic knee-ankle prostheses have often fallen short relative to passive microprocessor prostheses in time-based clinical outcome tests. User ambulation endurance is an alternative clinical outcome metric that may better highlight the benefits of robotic prostheses. However, previous studies were unable to show endurance benefits due to inaccurate high-level classification, discretized mid-level control, and insufficiently difficult ambulation tasks. In this case study, we present a phase-based mid-level prosthesis controller which yields biomimetic joint kinematics and kinetics that adjust to suit a continuum of tasks. We enrolled an individual with an above-knee amputation and challenged him to perform repeated, rapid laps of a circuit comprising activities of daily living with both his passive prosthesis and a robotic prosthesis. The participant demonstrated improved endurance with the robotic prosthesis and our mid-level controller compared to his passive prosthesis, completing over twice as many total laps before fatigue and muscle discomfort required him to stop. We also show that time-based outcome metrics fail to capture this endurance improvement, suggesting that alternative metrics related to endurance and fatigue may better highlight the clinical benefits of robotic prostheses. T. Kevin Best, Curt A. Laubscher, Ross J. Cortino, Shihao Cheng, Robert D. Gregg IV |
IROS | 3 |
| 2022 | Stair Ascent Phase-Variable Control of a Powered Knee-Ankle ProsthesisabstractPassive prostheses cannot provide the net positive work required at the knee and ankle for step-over stair ascent. Powered prostheses can provide this net positive work, but user synchronization of joint motion and power input are critical to enabling natural stair ascent gaits. In this work, we build on previous phase variable-based control methods for walking and propose a stair ascent controller driven by the motion of the user's residual thigh. We use reference kinematics from an able-bodied dataset to produce knee and ankle joint trajectories parameterized by gait phase. We redefine the gait cycle to begin at the point of maximum hip flexion instead of heel strike to improve the phase estimate. Able-bodied bypass adapter experiments demonstrate that the phase variable controller replicates normative able-bodied kinematic trajectories with a root mean squared error of 12.66° and 2.64° for the knee and ankle, respectively. The knee and ankle joints provided on average 0.39 J/kg and 0.21 J/kg per stride, compared to the normative averages of 0.34 J/kg and 0.21 J/kg, respectively. Thus, this controller allows powered knee-ankle prostheses to perform net positive mechanical work to assist stair ascent. Ross J. Cortino, Edgar Bolívar, T. Kevin Best, Robert D. Gregg IV |
ICRA | 1 |