Nicola Cavalcanti

dblp:344/2131 · also Nicola Alessandro Cavalcanti · DBLP profile ↗
← Back
6ranked-venue papers
0as first author
6since 2021 · last 2026
0009-0006-0674-0773ORCID · verified

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 5 · 5 since 2021Artificial intelligence and machine learning · 1 · 1 since 2021
YearPublicationVenuePosition
2026 NeuralBoneReg: An instance-specific label-free point cloud-based method for multi-modal bone surface registration
abstract
BACKGROUND: In computer- and robot-assisted orthopedic surgery (CAOS), patient-specific surgical plans are generated from preoperative medical imaging data to define target locations and implant trajectories. During surgery, these plans must be precisely transferred to the intraoperative setting to guide accurate execution. The accuracy and success of this transfer rely on cross-registration between preoperative and intraoperative data. However, the substantial heterogeneity across imaging modalities and devices renders this registration process challenging and error-prone, leading to inaccuracies. Consequently, more robust and accurate methods for automatic, modality-agnostic multimodal registration of bone surfaces would have a substantial clinical impact. METHODS: We propose NeuralBoneReg, an instance-specific self-supervised, surface-based framework for bone surface registration using 3D point clouds as an intermediate representation. NeuralBoneReg comprises two key components: an implicit neural unsigned distance field (UDF) module and a multilayer perceptron (MLP)-based registration module. The UDF module learns a neural representation of the preoperative bone model. The registration module solves both global initialization and local refinement by generating a set of transformation hypotheses to register the intraoperative point cloud with the preoperative neural UDF based on a coarse-to-fine strategy. Compared to state-of-the-art (SOTA) supervised registration, NeuralBoneReg operates in an instance-specific self-supervised manner, without requiring inter-subject training data with ground truth transformations. We evaluated NeuralBoneReg against baseline methods on two publicly available multi-modal datasets: a CT-ultrasound dataset of the fibula and tibia (UltraBones100k) and a CT-RGB-D dataset of spinal vertebrae (SpineDepth). The evaluation also includes a newly introduced CT-ultrasound dataset of cadaveric subjects containing femur and pelvis (UltraBonesHip), which will be made publicly available. RESULTS: Quantitative and qualitative results show that NeuralBoneReg achieves competitive performance across anatomies and modalities. On UltraBones100k, it obtains an RRE of 1.83±1.30°, an RTE of 2.02±1.30mm, an RR of 0.89, a CD of 0.82±0.12mm, and an HD95 of 2.06±0.36mm. On UltraBonesHip, it maintains stable performance with an RRE of 1.90±1.56°, an RTE of 2.21±0.86mm, an RR of 0.88, a CD of 2.50±1.08mm, and an HD95 of 8.97±4.08mm, while other methods degrade significantly. On SpineDepth, it achieves an RRE of 3.78±19.34°, an RTE of 2.80±3.75mm, an RR of 0.84, a CD of 1.78±1.61mm, and an HD95 of 4.26±4.58mm. Overall, the method consistently achieves accuracy close to pseudo ground truth across datasets. CONCLUSION: NeuralBoneReg achieves robust, accurate, and modality-agnostic registration of bone surfaces, offering a promising solution for reliable cross-modal alignment in computer- and robot-assisted orthopedic surgery.
Luohong Wu, Matthias Seibold, Nicola Cavalcanti, Yunke Ao, Roman Flepp, Aidana Massalimova, Lilian Calvet, Philipp Fürnstahl
Medical Image Anal.3
2025 SafeRPlan: Safe deep reinforcement learning for intraoperative planning of pedicle screw placement
abstract
Spinal fusion surgery requires highly accurate implantation of pedicle screw implants, which must be conducted in critical proximity to vital structures with a limited view of the anatomy. Robotic surgery systems have been proposed to improve placement accuracy. Despite remarkable advances, current robotic systems still lack advanced mechanisms for continuous updating of surgical plans during procedures, which hinders attaining higher levels of robotic autonomy. These systems adhere to conventional rigid registration concepts, relying on the alignment of preoperative planning to the intraoperative anatomy. In this paper, we propose a safe deep reinforcement learning (DRL) planning approach (SafeRPlan) for robotic spine surgery that leverages intraoperative observation for continuous path planning of pedicle screw placement. The main contributions of our method are (1) the capability to ensure safe actions by introducing an uncertainty-aware distance-based safety filter; (2) the ability to compensate for incomplete intraoperative anatomical information, by encoding a-priori knowledge of anatomical structures with neural networks pre-trained on pre-operative images; and (3) the capability to generalize over unseen observation noise thanks to the novel domain randomization techniques. Planning quality was assessed by quantitative comparison with the baseline approaches, gold standard (GS) and qualitative evaluation by expert surgeons. In experiments with human model datasets, our approach was capable of achieving over 5% higher safety rates compared to baseline approaches, even under realistic observation noise. To the best of our knowledge, SafeRPlan is the first safety-aware DRL planning approach specifically designed for robotic spine surgery.
Yunke Ao, Hooman Esfandiari, Fabio Carrillo, Christoph J. Laux, Yarden As, Ruixuan Li 0003, Kaat Van Assche, Ayoob Davoodi, Nicola Cavalcanti, Mazda Farshad, Benjamin F. Grewe, Emmanuel B. Vander Poorten, Andreas Krause 0001, Philipp Fürnstahl
Medical Image Anal.9
2025 Next-generation surgical navigation: Marker-less multi-view 6DoF pose estimation of surgical instruments
abstract
State-of-the-art research of traditional computer vision is increasingly leveraged in the surgical domain. A particular focus in computer-assisted surgery is to replace marker-based tracking systems for instrument localization with pure image-based 6DoF pose estimation using deep-learning methods. However, state-of-the-art single-view pose estimation methods do not yet meet the accuracy required for surgical navigation. In this context, we investigate the benefits of multi-view setups for highly accurate and occlusion-robust 6DoF pose estimation of surgical instruments and derive recommendations for an ideal camera system that addresses the challenges in the operating room. Our contributions are threefold. First, we present a multi-view RGB-D video dataset of ex-vivo spine surgeries, captured with static and head-mounted cameras and including rich annotations for surgeon, instruments, and patient anatomy. Second, we perform an extensive evaluation of three state-of-the-art single-view and multi-view pose estimation methods, analyzing the impact of camera quantities and positioning, limited real-world data, and static, hybrid, or fully mobile camera setups on the pose accuracy, occlusion robustness, and generalizability. Third, we design a multi-camera system for marker-less surgical instrument tracking, achieving an average position error of 1.01mm and orientation error of 0.89° for a surgical drill, and 2.79mm and 3.33° for a screwdriver under optimal conditions. Our results demonstrate that marker-less tracking of surgical instruments is becoming a feasible alternative to existing marker-based systems.
Jonas Hein, Nicola Cavalcanti, Daniel Suter, Lukas Zingg, Fabio Carrillo, Lilian Calvet, Mazda Farshad, Nassir Navab, Marc Pollefeys, Philipp Fürnstahl
Medical Image Anal.2
2024 Domain adaptation strategies for 3D reconstruction of the lumbar spine using real fluoroscopy data
Sascha Jecklin, Youyang Shen, Amandine Gout, Daniel Suter, Lilian Calvet, Lukas Zingg, Jennifer Straub, Nicola Cavalcanti, Mazda Farshad, Philipp Fürnstahl, Hooman Esfandiari
Medical Image Anal.8
2024 Automatic registration with continuous pose updates for marker-less surgical navigation in spine surgery
abstract
Established surgical navigation systems for pedicle screw placement have been proven to be accurate, but still reveal limitations in registration or surgical guidance. Registration of preoperative data to the intraoperative anatomy remains a time-consuming, error-prone task that includes exposure to harmful radiation. Surgical guidance through conventional displays has well-known drawbacks, as information cannot be presented in-situ and from the surgeon’s perspective. Consequently, radiation-free and more automatic registration methods with subsequent surgeon-centric navigation feedback are desirable. In this work, we present a marker-less approach that automatically solves the registration problem for lumbar spinal fusion surgery in a radiation-free manner. A deep neural network was trained to segment the lumbar spine and simultaneously predict its orientation, yielding an initial pose for preoperative models, which then is refined for each vertebra individually and updated in real-time with GPU acceleration while handling surgeon occlusions. An intuitive surgical guidance is provided thanks to the integration into an augmented reality based navigation system. The registration method was verified on a public dataset with a median of 100% successful registrations, a median target registration error of 2.7 mm, a median screw trajectory error of 1.6°and a median screw entry point error of 2.3 mm. Additionally, the whole pipeline was validated in an ex-vivo surgery, yielding a 100% screw accuracy and a median target registration error of 1.0 mm. Our results meet clinical demands and emphasize the potential of RGB-D data for fully automatic registration approaches in combination with augmented reality guidance.
Florentin Liebmann, Marco von Atzigen, Dominik Stütz, Julian Wolf 0001, Lukas Zingg, Daniel Suter, Nicola Cavalcanti, Laura Leoty, Hooman Esfandiari, Jess Gerrit Snedeker, Martin R. Oswald, Marc Pollefeys, Mazda Farshad, Philipp Fürnstahl
Medical Image Anal.7
2023 Automatic breach detection during spine pedicle drilling based on vibroacoustic sensing
abstract
Pedicle drilling is a complex and critical spinal surgery task. Detecting breach or penetration of the surgical tool to the cortical wall during pilot-hole drilling is essential to avoid damage to vital anatomical structures adjacent to the pedicle, such as the spinal cord, blood vessels, and nerves. Currently, the guidance of pedicle drilling is done using image-guided methods that are radiation intensive and limited to the preoperative information. This work proposes a new radiation-free breach detection algorithm leveraging a non-visual sensor setup in combination with deep learning approach. Multiple vibroacoustic sensors, such as a contact microphone, a free-field microphone, a tri-axial accelerometer, a uni-axial accelerometer, and an optical tracking system were integrated into the setup. Data were collected on four cadaveric human spines, ranging from L5 to T10. An experienced spine surgeon drilled the pedicles relying on optical navigation. A new automatic labeling method based on the tracking data was introduced. Labeled data was subsequently fed to the network in mel-spectrograms, classifying the data into breach and non-breach. Different sensor types, sensor positioning, and their combinations were evaluated. The best results in breach recall for individual sensors could be achieved using contact microphones attached to the dorsal skin (85.8%) and uni-axial accelerometers clamped to the spinous process of the drilled vertebra (81.0%). The best-performing data fusion model combined the latter two sensors with a breach recall of 98%. The proposed method shows the great potential of non-visual sensor fusion for avoiding screw misplacement and accidental bone breaches during pedicle drilling and could be extended to further surgical applications.
Aidana Massalimova, Maikel Timmermans, Nicola Cavalcanti, Daniel Suter, Matthias Seibold, Fabio Carrillo, Christoph J. Laux, Reto Sutter, Mazda Farshad, Kathleen Denis, Philipp Fürnstahl
Artif. Intell. Medicine3