Jordina Aviles Verdera

dblp:357/8505 · DBLP profile ↗
← Back
5ranked-venue papers
1as first author
5since 2021 · last 2026
0009-0007-7575-4244ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 5 · 1 first-author · 5 since 2021Graphics, computer vision, multimedia, augmented reality and games · 2 · 2 since 2021
YearPublicationVenuePosition
2026 Advances in automated fetal brain MRI segmentation and biometry: Insights from the FeTA 2024 challenge
abstract
Accurate fetal brain tissue segmentation and biometric measurement are essential for monitoring neurodevelopment and detecting abnormalities in utero. The Fetal Tissue Annotation (FeTA) Challenges have established robust multi-center benchmarks for evaluating state-of-the-art segmentation methods. This paper presents the results of the 2024 challenge edition, which introduced three key innovations. First, we introduced a topology-aware metric based on the Euler characteristic difference (ED) to overcome the performance plateau observed with traditional metrics like Dice or Hausdorff distance (HD), as the performance of the best models in segmentation surpassed the inter-rater variability. While the best teams reached similar scores in Dice (0.81-0.82) and HD95 (2.1-2.3 mm), ED provided greater discriminative power: the winning method achieved an ED of 20.9, representing roughly a 50% improvement over the second- and third-ranked teams despite comparable Dice scores. Second, we introduced a new 0.55T low-field MRI test set, which, when paired with high-quality super-resolution reconstruction, achieved the highest segmentation performance across all test cohorts (Dice=0.86, HD95=1.69, ED=6.26). This provides the first quantitative evidence that low-cost, low-field MRI can match or surpass high-field systems in automated fetal brain segmentation. Third, the new biometry estimation task exposed a clear performance gap: although the best model reached a mean average percentage error (MAPE) of 7.72%, most submissions failed to outperform a simple gestational-age-based linear regression model (MAPE=9.56%), and all remained above inter-rater variability with a MAPE of 5.38%. Finally, by analyzing the top-performing models from FeTA 2024 alongside those from previous challenge editions, we identify ensembles of 3D nnU-Net trained on both real and synthetic data with both image- and anatomy-level augmentations as the most effective approaches for fetal brain segmentation. Our quantitative analysis reveals that acquisition site, super-resolution strategy, and image quality are the primary sources of domain shift, informing recommendations to enhance the robustness and generalizability of automated fetal brain analysis methods.
Vladyslav Zalevskyi, Thomas Sanchez, Misha P. T. Kaandorp, Margaux Roulet, Diego Fajardo-Rojas, Liu Li 0001, Jana Hutter, Hongwei Li 0004, Matthew J. Barkovich, Luca Wilhelmi, Aline Dändliker, Céline Steger, Mériam Koob, Yvan Gomez, Anton Jakovcic, Melita Klaic, Ana Adzic, Pavel Markovic, Gracia Grabaric, Milan Rados, Jordina Aviles Verdera, Gregor Kasprian, Gregor Dovjak, Raphael Gaubert-Rachmühl, Maurice Aschwanden, Davood Karimi, Denis Peruzzo, Tommaso Ciceri, Giorgio Longari, Rachika E. Hamadache, Amina Bouzid, Xavier Lladó, Simone Chiarella, Gerard Martí-Juan, Miguel Ángel González Ballester, Marco Castellaro, Marco Pinamonti, Valentina Visani, Robin Cremese, Keïn Sam, Fleur Gaudfernau, Param Ahir, Mehul Parikh, Maximilian Zenk, Michael Baumgartner 0001, Klaus H. Maier-Hein, Li Tianhong, Zhao Longfei, Domen Preloznik, Ziga Spiclin, Jae Won Choi, Guotai Wang, Lyuyang Tong, Bo Du 0001, Andrea Gondova, Sungmin You, Kiho Im, Abdul Qayyum 0002, Moona Mazher, Steven A. Niederer, András Jakab, Roxane Licandro, Kelly Payette, Meritxell Bach Cuadra
Medical Image Anal.22
2025 Fetal body organ T2* relaxometry at low field strength (FOREST)
abstract
Fetal Magnetic Resonance Imaging (MRI) at low field strengths is an exciting new field in both clinical and research settings. Clinical low field (0.55T) scanners are beneficial for fetal imaging due to their reduced susceptibility-induced artifacts, increased T2* values, and wider bore (widening access for the increasingly obese pregnant population). However, the lack of standard automated image processing tools such as segmentation and reconstruction hampers wider clinical use. In this study, we present the Fetal body Organ T2* RElaxometry at low field STrength (FOREST) pipeline that analyzes ten major fetal body organs. Dynamic multi-echo multi-gradient sequences were acquired and automatically reoriented to a standard plane, reconstructed into a high-resolution volume using deformable slice-to-volume reconstruction, and then automatically segmented into ten major fetal organs. We extensively validated FOREST using an inter-rater quality analysis. We then present fetal T2* body organ growth curves made from 100 control subjects from a wide gestational age range (17-40 gestational weeks) in order to investigate the relationship of T2* with gestational age. The T2* values for all organs except the stomach and spleen were found to have a relationship with gestational age (p<0.05). FOREST is robust to fetal motion, and can be used for both normal and fetuses with pathologies. Low field fetal MRI can be used to perform advanced MRI analysis, and is a viable option for clinical scanning.
Kelly Payette, Alena Uus, Jordina Aviles Verdera, Megan Hall, Alexia Egloff, Maria Deprez, Raphaël Tomi-Tricot, Joseph V. Hajnal, Mary A. Rutherford, Lisa Story, Jana Hutter
Medical Image Anal.3
2025 HERON: High-Efficiency Real-Time Motion Quantification and Re-Acquisition for Fetal Diffusion MRI
abstract
Fetal diffusion MRI (dMRI) provides fascinating and clinically crucial insights into the microstructure of the human brain during development, but is highly sensitive to motion artifacts of fetal movement and maternal breathing, which impact data quality and limit diagnostic accuracy. This study introduces HERON, a robust, real-time, automatic pipeline designed to enhance fetal brain dMRI by performing motion assessment and re-acquisition. HERON leverages AI-driven brain localization, segmentation, and motion assessment on a clinical 0.55T scanner to automatically plan, quality check, and reacquire motion-affected dMRI volumes. Remaining inter-volume motion is corrected during post-processing. Tested in 20 cases, the pipeline effectively improved image quality, reduced intra- and inter-volume motion, and enabled more reliable quantitative analysis even in challenging cases. Excellent agreement with human observers (specificity 97%, sensitivity 92%) was shown and the mean Apparent Diffusion Coefficient and Intravoxel Incoherent Motion dropped in the majority of cases after correction. Improving fetal dMRI through an automatic AI-driven pipeline enables higher diagnostic quality and thus potentially wider use in both research and clinical applications.
Jordina Aviles Verdera, Antonia Bortolazzi, Sara Neves Silva, Kelly Payette, Kamilah St. Clair, Sarah McElroy, Shaihan J. Malik, Joseph V. Hajnal, Raphaël Tomi-Tricot, Mary A. Rutherford, Jana Hutter
IEEE Trans. Medical Imaging1
2024 Improving Cross-Domain Brain Tissue Segmentation in Fetal MRI with Synthetic Data
Vladyslav Zalevskyi, Thomas Sanchez, Margaux Roulet, Jordina Aviles Verdera, Jana Hutter, Hamza Kebiri, Meritxell Bach Cuadra
MICCAI (1)4
2023 An Automated Pipeline for Quantitative T2* Fetal Body MRI and Segmentation at Low Field
abstract
Fetal Magnetic Resonance Imaging at low field strengths is emerging as an exciting direction in perinatal health. Clinical low field (0.55T) scanners are beneficial for fetal imaging due to their reduced susceptibility-induced artefacts, increased T2* values, and wider bore (widening access for the increasingly obese pregnant population). However, the lack of standard automated image processing tools such as segmentation and reconstruction hampers wider clinical use. In this study, we introduce a semi-automatic pipeline using quantitative MRI for the fetal body at low field strength resulting in fast and detailed quantitative T2* relaxometry analysis of all major fetal body organs. Multi-echo dynamic sequences of the fetal body were acquired and reconstructed into a single high-resolution volume using deformable slice-to-volume reconstruction, generating both structural and quantitative T2* 3D volumes. A neural network trained using a semi-supervised approach was created to automatically segment these fetal body 3D volumes into ten different organs (resulting in dice values > 0.74 for 8 out of 10 organs). The T2* values revealed a strong relationship with GA in the lungs, liver, and kidney parenchyma (R 2 >0.5). This pipeline was used successfully for a wide range of GAs (17–40 weeks), and is robust to motion artefacts. Low field fetal MRI can be used to perform advanced MRI analysis, and is a viable option for clinical scanning.
Kelly Payette, Alena Uus, Jordina Aviles Verdera, Carla Avena Zampieri, Megan Hall, Lisa Story, Maria Deprez, Mary A. Rutherford, Joseph V. Hajnal, Sébastien Ourselin, Raphaël Tomi-Tricot, Jana Hutter
MICCAI (7)3