VLDB 2026 Research / reviewers in the wild / expert
Peter Gehlbach
dblp:40/7426 · also Peter L. Gehlbach
· DBLP profile ↗
34ranked-venue papers
0as first author
13since 2021 · last 2025
0000-0002-9608-9171ORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 25 · 9 since 2021Systems, architecture and hardware · 22 · 8 since 2021Applied, interdisciplinary, general and emerging computing · 11 · 4 since 2021Graphics, computer vision, multimedia, augmented reality and games · 5 · 1 since 2021Human-computer interaction and ubiquitous computing · 5 · 2 since 2021
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2025 | Real-Time Deformation-Aware Control for Autonomous Robotic Subretinal Injection Under iOCT GuidanceabstractRobotic platforms provide consistent and precise tool positioning that significantly enhances retinal microsurgery. Integrating such systems with intraoperative optical coherence tomography (iOCT) enables image-guided robotic interventions, allowing autonomous performance of advanced treatments, such as injecting therapeutic agents into the subretinal space. However, tissue deformations due to tool-tissue interactions constitute a significant challenge in autonomous iOCT-guided robotic subretinal injections. Such interactions impact correct needle positioning and procedure outcomes. This paper presents a novel method for autonomous subretinal injection under iOCT guidance that considers tissue deformations during the insertion procedure. The technique is achieved through real-time segmentation and 3D reconstruction of the surgical scene from densely sampled iOCT B-scans, which we refer to as B5_ scans. Using B5-scans we monitor the position of the instrument relative to a virtual target layer between the ILM and RPE. Our experiments on ex-vivo porcine eyes demonstrate dynamic adjustment of the insertion depth and overall improved accuracy in needle positioning compared to prior autonomous insertion approaches. Compared to a 35% success rate in subretinal bleb generation with previous approaches, our method reliably created subretinal blebs in 90% our experiments. The source code and data used in this study are publicly available on GitHub11https://github.com/demirarikan/virtual-Iayer-retinal-surgery. Demir Arikan, Peiyao Zhang, Michael Sommersperger, Shervin Dehghani, Mojtaba Esfandiari, Russell H. Taylor, M. Ali Nasseri, Peter Gehlbach, Nassir Navab, Iulian Iordachita |
ICRA | 8 |
| 2025 | A Deep Learning-Driven Autonomous System for Retinal Vein Cannulation: Validation Using a Chicken Embryo ModelabstractRetinal vein cannulation (RVC) is a minimally invasive microsurgical procedure for treating retinal vein occlusion (RVO), a leading cause of vision impairment. However, the small size and fragility of retinal veins, coupled with the need for high-precision, tremor-free needle manipulation, create significant technical challenges. These limitations highlight the need for robotic assistance to improve accuracy and stability. This study presents an automated robotic system with a top-down microscope and B-scan optical coherence tomography (OCT) imaging for precise depth sensing. Deep learning-based models enable real-time needle navigation, contact detection, and vein puncture recognition, using a chicken embryo model as a surrogate for human retinal veins. The system autonomously detects needle position and puncture events with 85% accuracy. The experiments demonstrate notable reductions in navigation and puncture times compared to manual methods. Our results demonstrate the potential of integrating advanced imaging and deep learning to automate microsurgical tasks, providing a pathway for safer and more reliable RVC procedures with enhanced precision and reproducibility. Peiyao Zhang, Mojtaba Esfandiari, Peter Gehlbach, Iulian Iordachita |
IROS | 4 |
| 2025 | Bimanual Manipulation of Steady-Hand Eye Robots With Adaptive Sclera Force Control: Cooperative Versus Teleoperation StrategiesabstractPerforming retinal vein cannulation (RVC) as a potential treatment for retinal vein occlusion (RVO) without the assistance of a surgical robotic system is very challenging to do safely. The main limitation is the physiological hand tremor of surgeons. Robot-assisted eye surgery technology may resolve the problems of hand tremors and fatigue and improve the safety and precision of RVC. The Steady-Hand Eye Robot (SHER) is an admittance-based robotic system that can filter out hand tremors and enables ophthalmologists to manipulate a surgical instrument inside the eye cooperatively. However, the admittance-based cooperative control mode does not safely minimize the contact force between the surgical instrument and the sclera to prevent tissue damage. In addition, features such as haptic feedback or hand motion scaling, which can improve the safety and precision of surgery, require a teleoperation control framework. This work presents, for the first time in the field of robot-assisted retinal microsurgery research, a registration-free bimanual adaptive teleoperation (BMAT) control framework using SHER 2.0 and SHER 2.1 robotic systems. Both SHERs are integrated with an adaptive force control (AFC) algorithm that dynamically and automatically minimizes the tool-sclera interaction forces, enforcing them within a safe limit. The scleral forces are measured using two fiber Bragg grating (FBG)-based force-sensing tools. The performance of the proposed BMAT control framework is evaluated by comparison with a bimanual adaptive cooperative (BMAC) framework in a vessel-following experiment conducted under a surgical microscope. Experimental results demonstrate the effectiveness of the BMAT control framework in performing a safe bimanual telemanipulation of the eye without over-stretching it, even in the absence of registration between the two robots. Mojtaba Esfandiari, Peter Gehlbach, Russell H. Taylor, Iulian Iordachita |
IEEE Trans. Hum. Mach. Syst. | 2 |
| 2024 | Colibri5: Real-Time Monocular 5-DoF Trocar Pose Tracking for Robot-Assisted Vitreoretinal SurgeryabstractRetinal surgery is a complex medical procedure that requires high precision dexterity to perform delicate instrument maneuvers with sub-millimeter accuracy. Minimizing the manual tremor and achieving precise and repeatable execution of surgical tasks has motivated the development of robotic platforms to overcome the limitations of manual surgery. However, specific tasks, such as instrument insertion through the trocar, are more challenging in robotic surgery than in conventional manual procedures since the robot control is often optimized for navigation inside the eye. This challenges the integration of robotic systems, creating a high cognitive load on the operator and prolonging the surgery time. Moreover, misalignment of the robot’s remote center of motion (RCM) and trocar position during the procedure can lead to excessive forces between the instrument and the trocar, potentially causing patient trauma. Precise and rapid localization of the trocars enables the automation of the insertion procedure and dynamic compensation of eye motion.In this work, we present a real-time marker-less method for 3D pose tracking of trocar, achieved with only a single monocular camera. Our experiments show promising results towards real-time trocar pose estimation and tracking, achieving an average error of 3◦in trocar orientation estimation, with an average processing time of 15 fps. This could serve as a foundation to improve robotic systems’ automation, integration, and efficiency of robotic systems for retinal surgery. The dataset created for this work is made publicly available. Shervin Dehghani, Michael Sommersperger, Mahdi Saleh, Alireza Alikhani, Benjamin Busam, Peter Gehlbach, Iulian Iordachita, Nassir Navab, M. Ali Nasseri |
ICRA | 6 |
| 2024 | Cooperative vs. Teleoperation Control of the Steady Hand Eye Robot with Adaptive Sclera Force Control: A Comparative StudyabstractA surgeon's physiological hand tremor can significantly impact the outcome of delicate and precise retinal surgery, such as retinal vein cannulation (RVC) and epiretinal membrane peeling. Robot-assisted eye surgery technology provides ophthalmologists with advanced capabilities such as hand tremor cancellation, hand motion scaling, and safety constraints that enable them to perform these otherwise challenging and high-risk surgeries with high precision and safety. Steady-Hand Eye Robot (SHER) with cooperative control mode can filter out surgeon's hand tremor, yet another important safety feature, that is, minimizing the contact force between the surgical instrument and sclera surface for avoiding tissue damage cannot be met in this control mode. Also, other capabilities, such as hand motion scaling and haptic feedback, require a teleoperation control framework. In this work, for the first time, we implemented a teleoperation control mode incorporated with an adaptive sclera force control algorithm using a PHANTOM Omni haptic device and a force-sensing surgical instrument equipped with Fiber Bragg Grating (FBG) sensors attached to the SHER 2.1 end-effector. This adaptive sclera force control algorithm allows the robot to dynamically minimize the tool-sclera contact force. Moreover, for the first time, we compared the performance of the proposed adaptive teleoperation mode with the cooperative mode by conducting a vessel-following experiment inside an eye phantom under a microscope. Mojtaba Esfandiari, Ji Woong Kim, Botao Zhao 0002, Golchehr Amirkhani, Muhammad Hadi, Peter Gehlbach, Russell H. Taylor, Iulian Iordachita |
ICRA | 6 |
| 2024 | Exploring the Needle Tip Interaction Force with Retinal Tissue Deformation in Vitreoretinal SurgeryabstractRecent advancements in age-related macular degeneration treatments necessitate precision delivery into the subretinal space, emphasizing minimally invasive procedures targeting the retinal pigment epithelium (RPE)-Bruch's membrane complex without causing trauma. Even for skilled surgeons, the inherent hand tremors during manual surgery can jeopardize the safety of these critical interventions. This has fostered the evolution of robotic systems designed to prevent such tremors. These robots are enhanced by FBG sensors, which sense the small force interactions between the surgical instruments and retinal tissue. To enable the community to design algorithms taking advantage of such force feedback data, this paper focuses on the need to provide a specialized dataset, integrating optical coherence tomography (OCT) imaging together with the aforementioned force data. We introduce a unique dataset, integrating force sensing data synchronized with OCT B-scan images, derived from a sophisticated setup involving robotic assistance and OCT integrated microscopes. Furthermore, we present a neural network model for image-based force estimation to demonstrate the dataset's applicability. Simon Pannek, Shervin Dehghani, Michael Sommersperger, Peiyao Zhang, Peter Gehlbach, M. Ali Nasseri, Iulian Iordachita, Nassir Navab |
ICRA | 5 |
| 2023 | Robotic Navigation Autonomy for Subretinal Injection via Intelligent Real-Time Virtual iOCT Volume SlicingabstractIn the last decade, various robotic platforms have been introduced that could support delicate retinal surgeries. Concurrently, to provide semantic understanding of the surgical area, recent advances have enabled microscope-integrated intraoperative Optical Coherent Tomography (iOCT) with high-resolution 3D imaging at near video rate. The combination of robotics and semantic understanding enables task autonomy in robotic retinal surgery, such as for subretinal injection. This procedure requires precise needle insertion for best treatment outcomes. However, merging robotic systems with iOCT intro-duces new challenges. These include, but are not limited to high demands on data processing rates and dynamic registration of these systems during the procedure. In this work, we propose a framework for autonomous robotic navigation for subretinal injection, based on intelligent real-time processing of iOCT volumes. Our method consists of an instrument pose estimation method, an online registration between the robotic and the iOCT system, and trajectory planning tailored for navigation to an injection target. We also introduce intelligent virtual B-scans, a volume slicing approach for rapid instrument pose estimation, which is enabled by Convolutional Neural Networks (CNNs). Our experiments on ex-vivo porcine eyes demonstrate the precision and repeatability of the method. Finally, we discuss identified challenges in this work and suggest potential solutions to further the development of such systems. Shervin Dehghani, Michael Sommersperger, Peiyao Zhang, Alejandro Martin-Gomez, Benjamin Busam, Peter Gehlbach, Nassir Navab, M. Ali Nasseri, Iulian Iordachita |
ICRA | 6 |
| 2023 | Autonomous Needle Navigation in Retinal Microsurgery: Evaluation in ex vivo Porcine EyesabstractImportant challenges in retinal microsurgery in-clude prolonged operating time, inadequate force feedback, and poor depth perception due to a constrained top-down view of the surgery. The introduction of robot-assisted technology could potentially deal with such challenges and improve the surgeon's performance. Motivated by such challenges, this work develops a strategy for autonomous needle navigation in retinal microsurgery aiming to achieve precise manipulation, reduced end-to-end surgery time, and enhanced safety. This is accomplished through real-time geometry estimation and chance-constrained Model Predictive Control (MPC) resulting in high positional accuracy while keeping scleral forces within a safe level. The robotic system is validated using both open-sky and intact (with lens and partial vitreous removal) ex vivo porcine eyes. The experimental results demonstrate that the generation of safe control trajectories is robust to small motions associated with head drift. The mean navigation time and scleral force for MPC navigation experiments are 7.208 s and 11.97 mN, which can be considered efficient and well within acceptable safe limits. The resulting mean errors along lateral directions of the retina are below 0.06 mm, which is below the typical hand tremor amplitude in retinal microsurgery. Peiyao Zhang, Ji Woong Kim, Peter Gehlbach, Iulian Iordachita, Marin Kobilarov |
ICRA | 3 |
| 2023 | Human-Robot Interaction in Retinal Surgery: A Comparative Study of Serial and Parallel Cooperative RobotsabstractCooperative robots for intraocular surgery allow surgeons to perform vitreoretinal surgery with high precision and stability. Several robot structural designs have shown capabilities to perform these surgeries. This research investigates the comparative performance of a serial and parallel cooperative-controlled robot in completing a retinal vessel-following task, with a focus on human-robot interaction performance and user experience. Our results indicate that despite differences in robot structure and interaction forces and torques, the two robots exhibited similar levels of performance in terms of general robot-to-patient interaction and average operating time. These findings have implications for the development and implementation of surgical robotics, suggesting that both serial and parallel cooperative-controlled robots can be effective for vitreoretinal surgery tasks. Botao Zhao 0002, Mojtaba Esfandiari, David E. Usevitch, Peter Gehlbach, Iulian Iordachita |
RO-MAN | 4 |
| 2023 | Simultaneous Online Registration-Independent Stiffness Identification and Tip Localization of Surgical Instruments in Robot-Assisted Eye SurgeryabstractNotable challenges during retinal surgery lend themselves to robotic assistance which has proven beneficial in providing a safe steady-hand manipulation. Efficient assistance from the robots heavily relies on accurate sensing of surgery states (e.g. instrument tip localization and tool-to-tissue interaction forces). Many of the existing tool tip localization methods require preoperative frame registrations or instrument calibrations. In this study using an iterative approach and by combining vision and force-based methods, we develop calibration- and registration-independent (RI) algorithms to provide online estimates of instrument stiffness (least squares and adaptive). The estimations are then combined with a state-space model based on the forward kinematics (FWK) of the Steady-Hand Eye Robot (SHER) and Fiber Brag Grating (FBG) sensor measurements. This is accomplished using a Kalman Filtering (KF) approach to improve the deflected instrument tip position estimations during robot-assisted eye surgery. The conducted experiments demonstrate that when the online RI stiffness estimations are used, the instrument tip localization results surpass those obtained from pre-operative offline calibrations for stiffness. Shahriar Sefati, Peter Gehlbach, Russell H. Taylor, Iulian Iordachita |
IEEE Trans. Robotics | 3 |
| 2022 | OCT-guided Robotic Subretinal Needle Injections: A Deep Learning-Based Registration ApproachabstractSubretinal injection (SI) is an ophthalmic surgical procedure that allows for the direct injection of therapeutic substances into the subretinal space to treat vitreoretinal disorders. Although this treatment has grown in popularity, various factors contribute to its difficulty. These include the retina’s fragile, nonregenerative tissue, as well as hand tremor and poor visual depth perception. In this context, the usage of robotic devices may reduce hand tremors and facilitate gradual and controlled SI. For the robot to successfully move to the target area, it needs to understand the spatial relationship between the attached needle and the tissue. The development of optical coherence tomography (OCT) imaging has resulted in a substantial advancement in visualizing retinal structures at micron resolution. This paper introduces a novel foundation for an OCT-guided robotic steering framework that enables a surgeon to plan and select targets within the OCT volume. At the same time, the robot automatically executes the trajectories necessary to achieve the selected targets. Our contribution consists of a novel combination of existing methods, creating an intraoperative OCT-Robot registration pipeline. We combined straightforward affine transformation computations with robot kinematics and a deep neural network-determined tool-tip location in OCT. We evaluate our framework’s capability in a cadaveric pig eye open-sky procedure and using an aluminum target board. Targeting the subretinal space of the pig eye produced encouraging results with a mean Euclidean error of 23.8μm. Kristina Mach, Shuwen Wei, Ji Woong Kim, Alejandro Martin-Gomez, Peiyao Zhang, Jin U. Kang, M. Ali Nasseri, Peter Gehlbach, Nassir Navab, Iulian Iordachita |
BIBM | 8 |
| 2022 | ColibriDoc: an Eye-in-Hand Autonomous Trocar Docking SystemabstractRetinal surgery is a complex medical procedure that requires exceptional expertise and dexterity. For this purpose, several robotic platforms are currently under development to enable or improve the outcome of microsurgical tasks. Since the control of such robots is often designed for navigation inside the eye in proximity to the retina, successful trocar docking and insertion of the instrument into the eye represents an additional cognitive effort, and is therefore one of the open challenges in robotic retinal surgery. For this purpose, we present a platform for autonomous trocar docking that combines computer vision and a robotic setup. Inspired by the Cuban Colibri (hummingbird) aligning its beak to a flower using only vision, we mount a camera onto the endeffector of a robotic system. By estimating the position and pose of the trocar, the robot is able to autonomously align and navigate the instrument towards the Trocar Entry Point (TEP) and finally perform the insertion. Our experiments show that the proposed method is able to accurately estimate the position and pose of the trocar and achieve repeatable autonomous docking. The aim of this work is to reduce the complexity of the robotic setup prior to the surgical task and therefore, increase the intuitiveness of the system integration into clinical workflow. Shervin Dehghani, Michael Sommersperger, Junjie Yang 0001, Mehrdad Salehi, Benjamin Busam, Kai Huang 0001, Peter Gehlbach, Iulian Iordachita, Nassir Navab, M. Ali Nasseri |
ICRA | 7 |
| 2022 | Y-Net: A Spatiospectral Dual-Encoder Network for Medical Image Segmentation
Azade Farshad, Yousef Yeganeh, Peter Gehlbach, Nassir Navab |
MICCAI (2) | 3 |
| 2020 | Towards Bimanual Vein Cannulation: Preliminary Study of a Bimanual Robotic System With a Dual Force Constraint ControllerabstractRetinal vein cannulation is a promising approach for treating retinal vein occlusion that involves injecting medicine into the occluded vessel to dissolve the clot. The approach remains largely unexploited clinically due to surgeon limitations in detecting interaction forces between surgical tools and retinal tissue. In this paper, a dual force constraint controller for robot-assisted retinal surgery was presented to keep the tool-to-vessel forces and tool-to-sclera forces below prescribed thresholds. A cannulation tool and forceps with dual force-sensing capability were developed and used to measure force information fed into the robot controller, which was implemented on existing Steady Hand Eye Robot platforms. The robotic system facilitates retinal vein cannulation by allowing a user to grasp the target vessel with the forceps and then enter the vessel with the cannula. The system was evaluated on an eye phantom. The results showed that, while the eyeball was subjected to rotational disturbances, the proposed controller actuates the robotic manipulators to maintain the average tool-to-vessel force at 10.9 mN and 13.1 mN and the average tool-to-sclera force at 38.1 mN and 41.2 mN for the cannula and the forcpes, respectively. Such small tool-to-tissue forces are acceptable to avoid retinal tissue injury. Additionally, two clinicians participated in a preliminary user study of the bimanual cannulation demonstrating that the operation time and tool-to-tissue forces are significantly decreased when using the bimanual robotic system as compared to freehand performance. Changyan He, Emily Yang, Müller G. Urias, Yang Yang 0103, Peter Gehlbach, Iulian Iordachita |
ICRA | 6 |
| 2020 | Autonomously Navigating a Surgical Tool Inside the Eye by Learning from DemonstrationabstractA fundamental challenge in retinal surgery is safely navigating a surgical tool to a desired goal position on the retinal surface while avoiding damage to surrounding tissues, a procedure that typically requires tens-of-microns accuracy. In practice, the surgeon relies on depth-estimation skills to localize the tool-tip with respect to the retina in order to perform the tool-navigation task, which can be prone to human error. To alleviate such uncertainty, prior work has introduced ways to assist the surgeon by estimating the tooltip distance to the retina and providing haptic or auditory feedback. However, automating the tool-navigation task itself remains unsolved and largely unexplored. Such a capability, if reliably automated, could serve as a building block to streamline complex procedures and reduce the chance for tissue damage. Towards this end, we propose to automate the tool-navigation task by learning to mimic expert demonstrations of the task. Specifically, a deep network is trained to imitate expert trajectories toward various locations on the retina based on recorded visual servoing to a given goal specified by the user. The proposed autonomous navigation system is evaluated in simulation and in physical experiments using a silicone eye phantom. We show that the network can reliably navigate a needle surgical tool to various desired locations within 137 μm accuracy in physical experiments and 94 μm in simulation on average, and generalizes well to unseen situations such as in the presence of auxiliary surgical tools, variable eye backgrounds, and brightness conditions. Ji Woong Kim, Changyan He, Müller G. Urias, Peter Gehlbach, Gregory D. Hager, Iulian Iordachita, Marin Kobilarov |
ICRA | 4 |
| 2020 | Auditory Feedback Effectiveness for Enabling Safe Sclera Force in Robot-Assisted Vitreoretinal Surgery: a Multi-User StudyabstractRobot-assisted retinal surgery has become increasingly prevalent in recent years in part due to the potential for robots to help surgeons improve the safety of an immensely delicate and difficult set of tasks. The integration of robots into retinal surgery has resulted in diminished surgeon perception of tool-to-tissue interaction forces due to robot's stiffness. The tactile perception of these interaction forces (sclera force) has long been a crucial source of feedback for surgeons who rely on them to guide surgical maneuvers and to prevent damaging forces from being applied to the eye. This problem is exacerbated when there are unfavorable sclera forces originating from patient movements (dynamic eyeball manipulation) during surgery which may cause the sclera forces to increase even drastically. In this study we aim at evaluating the efficacy of providing warning auditory feedback based on the level of sclera force measured by force sensing instruments. The intent is to enhance safety during dynamic eye manipulations in robot-assisted retinal surgery. The disturbances caused by lateral movement of patient's head are simulated using a piezo-actuated linear stage. The Johns Hopkins Steady-Hand Eye Robot (SHER), is then used in a multi-user experiment. Twelve participants are asked to perform a mock retinal surgery by following painted vessels inside an eye phantom using a force sensing instrument while auditory feedback is provided. The results indicate that the users are able to handle the eye motion disturbances while maintaining the sclera forces within safe boundaries when audio feedback is provided. Marina Roizenblatt, Niravkumar A. Patel, Peter Gehlbach, Iulian Iordachita |
IROS | 4 |
| 2020 | An Optimized Tilt Mechanism for a New Steady-Hand Eye RobotabstractRobot-assisted vitreoretinal surgery can filter surgeons' hand tremors and provide safe, accurate tool manipulation. In this paper, we report the design, optimization, and evaluation of a novel tilt mechanism for a new Steady-Hand Eye Robot (SHER). The new tilt mechanism features a four-bar linkage design and has a compact structure. Its kinematic configuration is optimized to minimize the required linear range of motion (LRM) for implementing a virtual remote center-of-motion (V-RCM) while tilting a surgical tool. Due to the different optimization constraints for the robots at the left and right sides of the human head, two configurations of this tilt mechanism are proposed. Experimental results show that the optimized tilt mechanism requires a significantly smaller LRM (e.g. 5.08 mm along Z direction and 8.77 mm along Y direction for left side robot) as compared to the slider-crank tilt mechanism used in the previous SHER (32.39 mm along Z direction and 21.10 mm along Y direction). The feasibility of the proposed tilt mechanism is verified in a mock bilateral robot-assisted vitreoretinal surgery. The ergonomically acceptable robot postures needed to access the surgical field is also determined. Jiahao Wu 0002, Gang Li 0018, Müller G. Urias, Niravkumar A. Patel, Yun-Hui Liu 0001, Peter Gehlbach, Russell H. Taylor, Iulian Iordachita |
IROS | 6 |
| 2019 | Adaptive Control of Sclera Force and Insertion Depth for Safe Robot-Assisted Retinal SurgeryabstractOne of the significant challenges of moving from manual to robot-assisted retinal surgery is the loss of perception of forces applied to the sclera (sclera forces) by the surgical tools. This damping of force feedback is primarily due to the stiffness and inertia of the robot. The diminished perception of tool-to-eye interactions might put the eye tissue at high risk of injury due to excessive sclera forces or extreme insertion of the tool into the eye. In the present study therefore a 1-dimensional adaptive control method is customized for 3-dimensional control of sclera force components and tool insertion depth and then implemented on the velocity-controlled Johns Hopkins Steady-Hand Eye Robot. The control method enables the robot to perform autonomous motions to make the sclera force and/or insertion depth of the tool tip to follow pre-defined desired and safe trajectories when they exceed safe bounds. A robotic light pipe holding application in retinal surgery is also investigated using the adaptive control method. The implementation results indicate that the adaptive control is able to achieve the imposed safety margins and prevent sclera forces and insertion depth from exceeding safe boundaries. Niravkumar A. Patel, Changyan He, Peter Gehlbach, Marin Kobilarov, Iulian Iordachita |
ICRA | 4 |
| 2019 | Toward Improving Patient Safety and Surgeon Comfort in a Synergic Robot-Assisted Eye Surgery: A Comparative StudyabstractWhen robotic assistance is present into vitreoretinal surgery, the surgeon will experience reduced sensory input that is otherwise derived from the tool's interaction with the eye wall (sclera). We speculate that disconnecting the surgeon from this sensory input may increase the risk of injury to the eye and affect the surgeon's usual technique. On the other hand, robot autonomous motion to enhance patient safety might inhibit the surgeons tool manipulation and diminish surgeon comfort with the procedure. In this study, to investigate the parameters of patient safety and surgeon comfort in a robot-assisted eye surgery, we implemented three different approaches designed to keep the scleral force in a safe range during a synergic eye manipulation task. To assess the surgeon comfort during these procedures, the amount of interference with the surgeons usual maneuvers has been analyzed by defining quantitative comfort metrics. The first two utilized scleral force control approaches are based on an adaptive force control method in which the robot actively counteracts any excessive force on the sclera. The third control method is based on a virtual fixture approach in which a virtual wall is created for the surgeon in the unsafe directions of manipulation. The performance of the utilized approaches was evaluated in user studies with two experienced retinal surgeons and the outcomes of the procedure were assessed using the defined safety and comfort metrics. Results of these analyses indicate the significance of the opted control paradigm on the outcome of a safe and comfortable robot-assisted eye surgery. Farshid Alambeigi, Ingrid E. Zimmer-Galler, Peter Gehlbach, Russell H. Taylor, Iulian Iordachita |
IROS | 4 |
| 2019 | A Novel Semi-Autonomous Control Framework for Retina Confocal Endomicroscopy Scanning*abstractIn this paper, a novel semi-autonomous control framework is presented for enabling probe-based confocal laser endomicroscopy (pCLE) scan of the retinal tissue. With pCLE, retinal layers such as nerve fiber layer (NFL) and retinal ganglion cell (RGC) can be scanned and characterized in real-time for an improved diagnosis and surgical outcome prediction. However, the limited field of view of the pCLE system and the micron-scale optimal focus distance of the probe, which are in the order of physiological hand tremor, act as barriers to successful manual scan of retinal tissue. Therefore, a novel sensorless framework is proposed for real-time semi-autonomous endomicroscopy scanning during retinal surgery. The framework consists of the Steady-Hand Eye Robot (SHER) integrated with a pCLE system, where the motion of the probe is controlled semi-autonomously. Through a hybrid motion control strategy, the system autonomously controls the confocal probe to optimize the sharpness and quality of the pCLE images, while providing the surgeon with the ability to scan the tissue in a tremor-free manner. Effectiveness of the proposed architecture is validated through experimental evaluations as well as a user study involving 9 participants. It is shown through statistical analyses that the proposed framework can reduce the work load experienced by the users in a statistically-significant manner, while also enhancing their performance in retaining pCLE images with optimized quality. Zhaoshuo Li, Guang-Zhong Yang, Russell H. Taylor, Mahya Shahbazi, Niravkumar A. Patel, Eimear O' Sullivan, Khushi Vyas, Preetham Chalasani, Peter Gehlbach, Iulian Iordachita |
IROS | 10 |
| 2019 | Towards securing the sclera against patient involuntary head movement in robotic retinal surgeryabstractRetinal surgery involves manipulating very delicate tissues within the confined area of eyeball. In such demanding practices, patient involuntary head movement might abruptly raise tool-to-eyeball interaction forces which would be detrimental to eye. This study is aimed at implementing different force control strategies and evaluating how they contribute to attaining sclera force safety while patient head drift is present. To simulate patient head movement, a piezoelectric-actuated linear stage is used to produce random motions in a single direction in random time intervals. Having an eye phantom attached to the linear stage then an experienced eye surgeon is asked to manipulate the eye and repeat a mock surgical task both with and without the assist of the Steady-Hand Eye Robot. For the freehand case, warning sounds were provided to the surgeon as auditory feedback to alert him about excessive slclra forces. For the robot-assisted experiments two variants of an adaptive sclera force control and a virtual fixture method were deployed to see how they can maintain eye safety under head drift circumstances. The results indicate that the developed robot control strategies are able to compensate for head drift and keep the sclera forces under safe levels as well as the free hand operation. Müller G. Urias, Niravkumar A. Patel, Changyan He, Russell H. Taylor, Peter Gehlbach, Iulian Iordachita |
RO-MAN | 6 |
| 2018 | User Behavior Evaluation in Robot-Assisted Retinal SurgeryabstractRetinal microsurgery is technically demanding and requires high surgical skill with very little room for manipulation error. The introduction of robotic assistance has the potential to enhance and expand a surgeon's manipulation capabilities during retinal surgery, i.e., improve precision, cancel physiological hand tremor, and provide sensing information. However, surgeon performance may also be negatively impacted by robotic assistance due to robot structural stiffness and nonintuitive controls. In complying with robotic constraints, the surgeon loses the dexterity of the human hand. In this paper, we present a preliminary experimental study to evaluate user behavior when affected by robotic assistance during mock retinal surgery. In these experiments user behavior is characterized by measuring the forces applied by the user to the sclera, the tool insertion/retraction speed, the tool insertion depth relative to the scleral entry point, and the duration of surgery. The users' behavior data is collected during three mock retinal surgery tasks with four users. Each task is conducted using both freehand and robot-assisted techniques. The univariate user behavior and the correlations of multiple parameters of user behavior are analyzed. The results show that robot assistance prolongs the duration of the surgery and increases the manipulation forces applied to sclera, but refines the insertion velocity and eliminates hand tremor. Changyan He, Marina Roizenblatt, Niravkumar A. Patel, Yang Yang 0103, Peter Gehlbach, Iulian Iordachita |
RO-MAN | 6 |
| 2015 | IRIS: Integrated Robotic Intraocular SnakeabstractRetinal surgery is one of the most technically challenging surgical disciplines. Many robotic systems have been developed to enhance the surgical capabilities. However, very few of them provide the surgeon the dexterity within the patient's eye to enable more flexible, more advanced surgical procedures. This paper presents a sub-millimeter intraocular dexterous robot, the Integrated Robotic Intraocular Snake (IRIS). The variable neutral-line mechanism is used to provide very high dexterity with a very small form factor. The IRIS distal dexterous unit is 0.9 mm in diameter and about 3 mm in length. It enables two rotational degrees of freedom at the distal end of the ophthalmic instruments. The analysis on contact mechanics provides a reference for the adjustment of the wire pretension. Redundant actuation is implemented by using one motor for each wire. A motion scaling transmission is developed to overcome the suboptimal resolution of the motors. A scale-up model of the IRIS is built for initial experimental evaluation. Preliminary results show that the scale-up IRIS can provide large range of motion. For given bending angle, the kinematic model can estimate the desired wire translation when the friction is not significant. The first prototype of the actual-scale IRIS is assembled and tested. Xingchi He, Vincent van Geirt, Peter Gehlbach, Russell H. Taylor, Iulian Iordachita |
ICRA | 3 |
| 2015 | Effects of micro-vibratory modulation during robot-assisted membrane peelingabstractIn retinal microsurgery, membrane peeling is a standard procedure requiring the delamination of a thin fibrous membrane adherent to the retina surface by applying very small forces. Robotic devices with combined force-sensing instruments have significant potential to assist this procedure by facilitating membrane delamination through induced micro-vibrations. However, defining the optimal frequency and amplitude for generating such vibrations, and updating these parameters during the procedure is not trivial. Automatic adjustment of these parameters via an adaptive control scheme is possible only if the individual parameter effects on delamination behavior are known. This study presents an experimental exploration of how micro-vibration amplitude and frequency affect membrane peeling forces alone. Combining a micromanipulator and a force-sensing micro-forceps, several peeling experiments were done on artificial phantoms (bandages) and inner shell membrane of raw chicken eggs. In the tested range of micro-vibration frequencies (10-50 Hz) the average delamination force was minimized mostly at 30 Hz for the bandages and at 50 Hz for the egg membranes. Increasing the micro-vibration amplitude from 50 μm up to 150 μm provided further reduction in average force, thus facilitated membrane delamination. Berk Gonenc, Peter Gehlbach, Russell H. Taylor, Iulian Iordachita |
IROS | 2 |
| 2014 | Towards robot-assisted vitreoretinal surgery: Force-sensing micro-forceps integrated with a handheld micromanipulatorabstractIn vitreoretinal practice, controlled tremor-free motion and limitation of applied forces to the retina are two highly desired features. This study addresses both requirements with a new integrated system: a force-sensing motorized micro-forceps combined with an active tremor-canceling handheld micromanipulator, known as Micron. The micro-forceps is a 20 Ga instrument that is mechanically decoupled from its handle and senses the transverse forces at its tip with an accuracy of 0.3 mN. Membrane peeling trials on a bandage phantom revealed a 60-95% reduction in the 2-20 Hz band in both the tip force and position spectra, while peeling forces remained below the set safety threshold. Berk Gonenc, Ellen Feldman, Peter Gehlbach, James Handa, Russell H. Taylor, Iulian Iordachita |
ICRA | 3 |
| 2014 | A multi-function force sensing instrument for variable admittance robot control in retinal microsurgeryabstractRobotic systems have the potential to assist vitreoretinal surgeons in extremely difficult surgical tasks inside the human eye. In addition to reducing hand tremor and improving tool positioning, a robotic assistant can provide assistive motion guidance using virtual fixtures, and incorporate real-time feedback from intraocular force sensing ophthalmic instruments to present tissue manipulation forces, that are otherwise physically imperceptible to the surgeon. This paper presents the design of an FBG-based, multi-function instrument that is capable of measuring mN-level forces at the instrument tip located inside the eye, and also the sclera contact location on the instrument shaft and the corresponding contact force. The given information is used to augment cooperatively controlled robot behavior with variable admittance control. This effectively creates an adaptive remote center-of-motion (RCM) constraint to minimize eye motion, but also allows the translation of the RCM location if the instrument is not near the retina. In addition, it provides force scaling for sclera force feedback. The calibration and validation of the multi-function force sensing instrument are presented, along with demonstration and performance assessment of the variable admittance robot control on an eye phantom. Xingchi He, Marcin Balicki, Peter Gehlbach, James Handa, Russell H. Taylor, Iulian Iordachita |
ICRA | 3 |
| 2013 | A comparative study for robot assisted vitreoretinal surgery: Micron vs. the Steady-Hand RobotabstractIn vitreoretinal surgery, application of excessive forces and unintentional motion due to hand-tremor can easily result in serious complications. Robotic assistance when combined with tool-to-tissue force sensing capabilities has significant potential to improve such practice. In this paper, we evaluate the membrane peeling performance of a single user for two distinct robotic systems with integrated force sensing capabilities: Micron and the Steady-Hand Robot. We show that these systems provide promising performance improvement with similar impact on peeling forces and comparable tremor cancellation trends. Berk Gonenc, James Handa, Peter Gehlbach, Russell H. Taylor, Iulian Iordachita |
ICRA | 3 |
| 2013 | A novel dual force sensing instrument with cooperative robotic assistant for vitreoretinal surgeryabstractRobotic assistants and smart surgical instruments have been developed to overcome many significant physiological limitations faced by vitreoretinal surgeons, one of which is lack of force perception below 7.5 mN. This paper reports the development of a new force sensor based on fiber Bragg grating (FBG) with the ability to sense forces at the tip of the surgical instrument located inside the eye and also provide information about instrument interaction with the sclera. The sclera section provides vital feedback for cooperative robot control to minimize potentially dangerous forces on the eye. Preliminary results with 2×2 degree-of-freedom (DOF) sensor and force scaling robot control demonstrate significant reduction of forces on the sclera. The design and analysis of the sensor is presented along with a simulated robot assisted retinal membrane peeling on a phantom with sclera constraints and audio feedback. Xingchi He, Marcin Balicki, Peter Gehlbach, James Handa, Russell H. Taylor, Iulian Iordachita |
ICRA | 3 |
| 2013 | Comparison of Baseline Tremor under Various Microsurgical ConditionsabstractThis paper presents the characterization and comparison of physiological tremor for pointing tasks in multiple environments, as a baseline for performance evaluation of microsurgical robotics. Previous studies have examined the characteristics of physiological tremor under laboratory settings as well as different operating conditions. However, different test methods make the comparison of results across trials and conditions difficult. Two vitroretinal microsurgeons were evaluated while performing a pointing task with no entry-point constraint, constrained by an artificial eye model, and constrained by a rabbit eye in vivo. For the three respective conditions the 3D RMS positioning error was 144 μm, 258 μm, and 285 μm, and maximum 3D error was 349 μm, 647 μm, and 696 μm. A spectral analysis was also performed, confirming a distinct peak near in the 6-12 Hz frequency range, characteristic of hand tremor during tasks in all three environments. Trent S. Wells, Sungwook Yang, Robert A. MacLachlan, James Handa, Peter Gehlbach, Cameron N. Riviere |
SMC | 5 |
| 2012 | Preliminary evaluation of a micro-force sensing handheld robot for vitreoretinal surgeryabstractHighly accurate positioning is fundamental to the performance of vitreoretinal microsurgery. Of vitreoretinal procedures, membrane peeling is among the most prone to complications since extremely delicate manipulation of retinal tissue is required. Associated tool-to-tissue interaction forces are usually below the threshold of human perception, and the surgical tools are moved very slowly, within the 0.1-0.5 mm/s range. During the procedure, unintentional tool motion and excessive forces can easily give rise to vision loss or irreversible damage to the retina. A successful surgery includes two key features: controlled tremor-free tool motion and control of applied force. In this study, we present the potential benefits of a micro-force sensing robot in vitreoretinal surgery. Our main contribution is implementing fiber Bragg grating based force sensing in an active tremor canceling handheld micromanipulator, known as Micron, to measure tool-to-tissue interaction forces in real time. Implemented auditory sensory substitution assists in reducing and limiting forces. In order to test the functionality and performance, the force sensing Micron was evaluated in peeling experiments with adhesive bandages and with the inner shell membrane from chicken eggs. Our findings show that the combination of active tremor canceling together with auditory sensory substitution is the most promising aid that keeps peeling forces below 7 mN with a significant reduction in 2-20 Hz oscillations. Berk Gonenc, Marcin Balicki, James Handa, Peter Gehlbach, Cameron N. Riviere, Russell H. Taylor, Iulian Iordachita |
IROS | 4 |
| 2011 | Unified Detection and Tracking in Retinal Microsurgery
Raphael Sznitman, Anasuya Basu, Rogério Richa, Jim Handa, Peter Gehlbach, Russell H. Taylor, Bruno Jedynak, Gregory D. Hager |
MICCAI (1) | 5 |
| 2010 | Micro-force Sensing in Robot Assisted Membrane Peeling for Vitreoretinal Surgery
Marcin Balicki, Ali Uneri, Iulian Iordachita, James Handa, Peter Gehlbach, Russell H. Taylor |
MICCAI (3) | 5 |
| 2010 | Adaptive Multispectral Illumination for Retinal Microsurgery
Raphael Sznitman, Diego Rother, James Handa, Peter Gehlbach, Gregory D. Hager, Russell H. Taylor |
MICCAI (3) | 4 |
| 2009 | Single Fiber Optical Coherence Tomography Microsurgical Instruments for Computer and Robot-Assisted Retinal Surgery
Marcin Balicki, Jae-Ho Han, Iulian Iordachita, Peter Gehlbach, James Handa, Russell H. Taylor, Jin U. Kang |
MICCAI (1) | 4 |