VLDB 2026 Research / reviewers in the wild / expert
Pablo Lamata
dblp:42/1947
· DBLP profile ↗
18ranked-venue papers
3as first author
5since 2021 · last 2025
0000-0002-3097-4928ORCID · verified
Domains — the database's venue-derived domains; a paper can count in several
Applied, interdisciplinary, general and emerging computing · 16 · 3 first-author · 5 since 2021Artificial intelligence and machine learning · 2Graphics, computer vision, multimedia, augmented reality and games · 1 · 1 first-author
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2025 | Anatomical-electrical coupling of cardiac axes: Definitions and population variability for advancing personalised ECG interpretationabstractElectrocardiogram (ECG) recordings are affected by the heart's three-dimensional orientation within the thorax, i.e., the anatomical axis. Various cardiac conditions can cause the anatomical axis to shift and/or alter the pattern of electrical activation, leading to changes in the electrical axis. Nevertheless, there remains a lack of a formal, population-level study of the interplay between the cardiac anatomical and electrical axes and the factors that affect them. In this context, this study aimed to: (1) propose standardised definitions for the cardiac anatomical and electrical axes, (2) characterise their population-wide interplay in healthy conditions, (3) evaluate the impact of hypertension on their distribution and (4) identify associations with phenotypical and disease characteristics. Using cardiac magnetic resonance images and 12-lead ECGs from ~39,000 UK Biobank participants, patient-specific, paired biventricular geometries and vectorcardiograms were constructed. Five anatomical and four electrical axis definitions were computed, with the optimal pair of definitions selected based on their mutual alignment in 3D space within 28,000 healthy subjects. Accordingly, the anatomical axis was defined as the vector from the apex to the spatial centre of the four valves, and the electrical axis as the direction of the maximum QRS dipole. Mean angular separation in 3D, [Formula: see text], was 145.0° ± 16.8° in the healthy cohort. The electrical axes exhibited a much larger variability, and strong evidence of anatomical-electrical coupling was identified. Increasing BMI notably affected the anatomical axis, rotating the heart more horizontally-a pattern mirrored by the electrical axis. Both axes were also significantly influenced by sex and, to a lesser extent, age. The axes were then studied in the sub-cohort of ~3,500 UK BioBank participants with primary hypertension, where a similar rotational pattern as that with increasing BMI was revealed. Finally, phenome-wide association studies in the 39,000 participants reveal associations between the axes angular metrics and phenotypes signalling an increased afterload, and an association to hypertension among other clinical conditions. These findings underscore the complex anatomical-electrical interplay and highlight the potential of cardiac axes biomarkers for an improved clinical ECG interpretation and disease characterisation. Mohammad Kayyali, Ana Mincholé, Shuang Qian, Alistair A. Young, Devran Ugurlu, Elliot Fairweather, Steven A. Niederer, John Whitaker, Martin J. Bishop 0001, Pablo Lamata |
PLoS Comput. Biol. | 10 |
| 2022 | Correction: Linking statistical shape models and simulated function in the healthy adult human heartabstract[This corrects the article DOI: 10.1371/journal.pcbi.1008851.]. Cristóbal Rodero, Marina Strocchi, Maciej Marciniak, Stefano Longobardi, John Whitaker, Mark D. O'Neill, Karli Gillette, Christoph M. Augustin, Gernot Plank, Edward J. Vigmond, Pablo Lamata, Steven A. Niederer |
PLoS Comput. Biol. | 11 |
| 2021 | Non-invasive estimation of relative pressure for intracardiac flows using virtual work-energyabstractIntracardiac blood flow is driven by differences in relative pressure, and assessing these is critical in understanding cardiac disease. Non-invasive image-based methods exist to assess relative pressure, however, the complex flow and dynamically moving fluid domain of the intracardiac space limits assessment. Recently, we proposed a method, νWERP, utilizing an auxiliary virtual field to probe relative pressure through complex, and previously inaccessible flow domains. Here we present an extension of νWERP for intracardiac flow assessments, solving the virtual field over sub-domains to effectively handle the dynamically shifting flow domain. The extended νWERP is validated in an in-silico benchmark problem, as well as in a patient-specific simulation model of the left heart, proving accurate over ranges of realistic image resolutions and noise levels, as well as superior to alternative approaches. Lastly, the extended νWERP is applied on clinically acquired 4D Flow MRI data, exhibiting realistic ventricular relative pressure patterns, as well as indicating signs of diastolic dysfunction in an exemplifying patient case. Summarized, the extended νWERP approach represents a directly applicable implementation for intracardiac flow assessments. David Marlevi, Maximilian Balmus, Andreas Hessenthaler, Federica Viola, Daniel Fovargue, Adelaide de Vecchi, Pablo Lamata, Nicholas S. Burris, Francis D. Pagani, Jan E. Engvall, Elazer R. Edelman, Tino Ebbers, David Nordsletten |
Medical Image Anal. | 7 |
| 2021 | Linking statistical shape models and simulated function in the healthy adult human heartabstractCardiac anatomy plays a crucial role in determining cardiac function. However, there is a poor understanding of how specific and localised anatomical changes affect different cardiac functional outputs. In this work, we test the hypothesis that in a statistical shape model (SSM), the modes that are most relevant for describing anatomy are also most important for determining the output of cardiac electromechanics simulations. We made patient-specific four-chamber heart meshes (n = 20) from cardiac CT images in asymptomatic subjects and created a SSM from 19 cases. Nine modes captured 90% of the anatomical variation in the SSM. Functional simulation outputs correlated best with modes 2, 3 and 9 on average (R = 0.49 ± 0.17, 0.37 ± 0.23 and 0.34 ± 0.17 respectively). We performed a global sensitivity analysis to identify the different modes responsible for different simulated electrical and mechanical measures of cardiac function. Modes 2 and 9 were the most important for determining simulated left ventricular mechanics and pressure-derived phenotypes. Mode 2 explained 28.56 ± 16.48% and 25.5 ± 20.85, and mode 9 explained 12.1 ± 8.74% and 13.54 ± 16.91% of the variances of mechanics and pressure-derived phenotypes, respectively. Electrophysiological biomarkers were explained by the interaction of 3 ± 1 modes. In the healthy adult human heart, shape modes that explain large portions of anatomical variance do not explain equivalent levels of electromechanical functional variation. As a result, in cardiac models, representing patient anatomy using a limited number of modes of anatomical variation can cause a loss in accuracy of simulated electromechanical function. Cristóbal Rodero, Marina Strocchi, Maciej Marciniak, Stefano Longobardi, John Whitaker, Mark D. O'Neill, Karli Gillette, Christoph M. Augustin, Gernot Plank, Edward J. Vigmond, Pablo Lamata, Steven A. Niederer |
PLoS Comput. Biol. | 11 |
| 2021 | Generating Synthetic Labeled Data From Existing Anatomical Models: An Example With Echocardiography SegmentationabstractDeep learning can bring time savings and increased reproducibility to medical image analysis. However, acquiring training data is challenging due to the time-intensive nature of labeling and high inter-observer variability in annotations. Rather than labeling images, in this work we propose an alternative pipeline where images are generated from existing high-quality annotations using generative adversarial networks (GANs). Annotations are derived automatically from previously built anatomical models and are transformed into realistic synthetic ultrasound images with paired labels using a CycleGAN. We demonstrate the pipeline by generating synthetic 2D echocardiography images to compare with existing deep learning ultrasound segmentation datasets. A convolutional neural network is trained to segment the left ventricle and left atrium using only synthetic images. Networks trained with synthetic images were extensively tested on four different unseen datasets of real images with median Dice scores of 91, 90, 88, and 87 for left ventricle segmentation. These results match or are better than inter-observer results measured on real ultrasound datasets and are comparable to a network trained on a separate set of real images. Results demonstrate the images produced can effectively be used in place of real data for training. The proposed pipeline opens the door for automatic generation of training data for many tasks in medical imaging as the same process can be applied to other segmentation or landmark detection tasks in any modality. The source code and anatomical models are available to other researchers.11https://adgilbert.github.io/data-generation/ Andrew Gilbert, Maciej Marciniak, Cristóbal Rodero, Pablo Lamata, Eigil Samset, Kristin McLeod |
IEEE Trans. Medical Imaging | 4 |
| 2020 | Non-invasive estimation of relative pressure in turbulent flow using virtual work-energyabstractVascular pressure differences are established risk markers for a number of cardiovascular diseases. Relative pressures are, however, often driven by turbulence-induced flow fluctuations, where conventional non-invasive methods may yield inaccurate results. Recently, we proposed a novel method for non-turbulent flows, νWERP, utilizing the concept of virtual work-energy to accurately probe relative pressure through complex branching vasculature. Here, we present an extension of this approach for turbulent flows: νWERP-t. We present a theoretical method derivation based on flow covariance, quantifying the impact of flow fluctuations on relative pressure. νWERP-t is tested on a set of in-vitro stenotic flow phantoms with data acquired by 4D flow MRI with six-directional flow encoding, as well as on a patient-specific in-silico model of an acute aortic dissection. Over all tests νWERP-t shows improved accuracy over alternative energy-based approaches, with excellent recovery of estimated relative pressures. In particular, the use of a guaranteed divergence-free virtual field improves accuracy in cases where turbulent flows skew the apparent divergence of the acquired field. With the original νWERP allowing for assessment of relative pressure into previously inaccessible vasculatures, the extended νWERP-t further enlarges the method's clinical scope, underlining its potential as a novel tool for assessing relative pressure in-vivo. David Marlevi, Hojin Ha, Desmond Dillon-Murphy, João Filipe Fernandes, Daniel Fovargue, Massimiliano Colarieti-Tosti, Matilda Larsson, Pablo Lamata, C. Alberto Figueroa, Tino Ebbers, David Nordsletten |
Medical Image Anal. | 8 |
| 2020 | Real-time diameter of the fetal aorta from ultrasoundabstractAbstract The automatic analysis of ultrasound sequences can substantially improve the efficiency of clinical diagnosis. This article presents an attempt to automate the challenging task of measuring the vascular diameter of the fetal abdominal aorta from ultrasound images. We propose a neural network architecture consisting of three blocks: a convolutional neural network (CNN) for the extraction of imaging features, a convolution gated recurrent unit (C-GRU) for exploiting the temporal redundancy of the signal, and a regularized loss function, calledCyclicLoss, to impose our prior knowledge about the periodicity of the observed signal. The solution is investigated with a cohort of 25 ultrasound sequences acquired during the third-trimester pregnancy check, and with 1000 synthetic sequences. In the extraction of features, it is shown that a shallow CNN outperforms two other deep CNNs with both the real and synthetic cohorts, suggesting that echocardiographic features are optimally captured by a reduced number of CNN layers. The proposed architecture, working with the shallow CNN, reaches an accuracy substantially superior to previously reported methods, providing an average reduction of the mean squared error from 0.31 (state-of-the-art) to 0.09 $$\mathrm{mm}^2$$ mm2 , and a relative error reduction from 8.1 to 5.3%. The mean execution speed of the proposed approach of 289 frames per second makes it suitable for real-time clinical use. Nicolò Savioli, Enrico Grisan, Silvia Visentin, Erich Cosmi, Giovanni Montana, Pablo Lamata |
Neural Comput. Appl. | 6 |
| 2019 | Scar shape analysis and simulated electrical instabilities in a non-ischemic dilated cardiomyopathy patient cohortabstractThis paper presents a morphological analysis of fibrotic scarring in non-ischemic dilated cardiomyopathy, and its relationship to electrical instabilities which underlie reentrant arrhythmias.Two dimensional electrophysiological simulation models were constructed from a set of 699 late gadolinium enhanced cardiac magnetic resonance images originating from 157 patients.Areas of late gadolinium enhancement (LGE) in each image were assigned one of 10 possible microstructures, which modelled the details of fibrotic scarring an order of magnitude below the MRI scan resolution.A simulated programmed electrical stimulation protocol tested each model for the possibility of generating either a transmural block or a transmural reentry.The outcomes of the simulations were compared against morphological LGE features extracted from the images.Models which blocked or reentered, grouped by microstructure, were significantly different from one another in myocardial-LGE interface length, number of components and entropy, but not in relative area and transmurality.With an unknown microstructure, transmurality alone was the best predictor of block, whereas a combination of interface length, transmurality and number of components was the best predictor of reentry in linear discriminant analysis. Author summaryNon-ischemic dilated cardiomyopathy is a disease in which the lower left chamber of the heart is abnormally large.The cause of the disease can be anything that is not a loss of blood supply to the heart.Many patients with non-ischemic dilated cardiomyopathy have scars in their hearts which can be detected with magnetic resonance imaging.These scars are thought to disrupt the flow of electricity through the heart and cause deadly rhythm Gabriel Balaban, Brian Halliday, Wenjia Bai, Bradley Porter, Carlotta Malvuccio, Pablo Lamata, C. Aldo Rinaldi, Gernot Plank, Daniel Rueckert, Sanjay K. Prasad, Martin J. Bishop 0001 |
PLoS Comput. Biol. | 6 |
| 2018 | Temporal Convolution Networks for Real-Time Abdominal Fetal Aorta Analysis with Ultrasound
Nicolò Savioli, Silvia Visentin, Erich Cosmi, Enrico Grisan, Pablo Lamata, Giovanni Montana |
ICANN (2) | 5 |
| 2015 | Non-invasive pressure difference estimation from PC-MRI using the work-energy equationabstractPressure difference is an accepted clinical biomarker for cardiovascular disease conditions such as aortic coarctation. Currently, measurements of pressure differences in the clinic rely on invasive techniques (catheterization), prompting development of non-invasive estimates based on blood flow. In this work, we propose a non-invasive estimation procedure deriving pressure difference from the work-energy equation for a Newtonian fluid. Spatial and temporal convergence is demonstrated on in silico Phase Contrast Magnetic Resonance Image (PC-MRI) phantoms with steady and transient flow fields. The method is also tested on an image dataset generated in silico from a 3D patient-specific Computational Fluid Dynamics (CFD) simulation and finally evaluated on a cohort of 9 subjects. The performance is compared to existing approaches based on steady and unsteady Bernoulli formulations as well as the pressure Poisson equation. The new technique shows good accuracy, robustness to noise, and robustness to the image segmentation process, illustrating the potential of this approach for non-invasive pressure difference estimation. Fabrizio Donati, C. Alberto Figueroa, Nicolas Smith, Pablo Lamata, David Nordsletten |
Medical Image Anal. | 4 |
| 2013 | The estimation of patient-specific cardiac diastolic functions from clinical measurementsabstractAn unresolved issue in patients with diastolic dysfunction is that the estimation of myocardial stiffness cannot be decoupled from diastolic residual active tension (AT) because of the impaired ventricular relaxation during diastole. To address this problem, this paper presents a method for estimating diastolic mechanical parameters of the left ventricle (LV) from cine and tagged MRI measurements and LV cavity pressure recordings, separating the passive myocardial constitutive properties and diastolic residual AT. Dynamic C1-continuous meshes are automatically built from the anatomy and deformation captured from dynamic MRI sequences. Diastolic deformation is simulated using a mechanical model that combines passive and active material properties. The problem of non-uniqueness of constitutive parameter estimation using the well known Guccione law is characterized by reformulation of this law. Using this reformulated form, and by constraining the constitutive parameters to be constant across time points during diastole, we separate the effects of passive constitutive properties and the residual AT during diastolic relaxation. Finally, the method is applied to two clinical cases and one control, demonstrating that increased residual AT during diastole provides a potential novel index for delineating healthy and pathological cases. Jiahe Xi, Pablo Lamata, Steven A. Niederer, Sander Land, Wenzhe Shi, Xiahai Zhuang, Sébastien Ourselin, Simon G. Duckett, Anoop Shetty, C. Aldo Rinaldi, Daniel Rueckert, Reza Razavi, Nicolas Smith |
Medical Image Anal. | 2 |
| 2013 | Model-Based Vasculature Extraction From Optical Fluorescence Cryomicrotome ImagesabstractThe aim of this study was to develop a novel method to reconstruct 3-D coronary vasculature from cryomicrotome images, comprised of two distinct sets of data-fluorescent microsphere beads and coronary vasculature. Fluorescent beads and cast injected into the vasculature were separately imaged with different filter settings to obtain the microsphere and vascular data, respectively. To extract the vascular anatomy, light scattering in the tissue was modelled using a point spread function (PSF). The PSF was parametrized by optical tissue excitation and emission attenuation coefficients, which were estimated by fitting simulated images of microspheres convolved with the PSF model to the experimental microsphere images. These parameters were then applied within a new model-based method for vessel radius estimation. Current state-of-the-art radii estimation methods and the proposed model-based method were applied on vessel phantoms. In this validation study, the full-width half-maximum method of radii estimation, when performed on the raw data without correcting for the optical blurring, resulted in 42.9% error on average for the 170 μm vessel. In comparison, the model-based method resulted in 0.6% error on average for the same phantom. Whole-organ porcine coronary vasculature was automatically reconstructed with the new model-based vascular extraction method. Ayush Goyal, Jack Lee, Pablo Lamata, Jeroen P. H. M. van den Wijngaard, Pepijn van Horssen, Jos A. E. Spaan, Maria Siebes, Vicente Grau, Nicolas Smith |
IEEE Trans. Medical Imaging | 3 |
| 2013 | Quality Metrics for High Order Meshes: Analysis of the Mechanical Simulation of the Heart BeatabstractThe quality of a computational mesh is an important characteristic for stable and accurate simulations. Quality depends on the regularity of the initial mesh, and in mechanical simulations it evolves in time, with deformations causing changes in volume and distortion of mesh elements. Mesh quality metrics are therefore relevant for both mesh personalization and the monitoring of the simulation process. This work evaluates the significance, in meshes with high order interpolation, of four quality metrics described in the literature, applying them to analyse the stability of the simulation of the heart beat. It also investigates how image registration and mesh warping parameters affect the quality and stability of meshes. Jacobian-based metrics outperformed or matched the results of coarse geometrical metrics of aspect ratio or orthogonality, although they are more expensive computationally. The stability of simulations of a complete heart cycle was best predicted with a specificity of 61%, sensitivity of 85%, and only nominal differences were found changing the intra-element and per-element combination of quality values. A compromise between fitting accuracy and mesh stability and quality was found. Generic geometrical quality metrics have a limited success predicting stability, and an analysis of the simulation problem may be required for an optimal definition of quality. Pablo Lamata, Ishani Roy, Bojan Blazevic, Andrew Crozier, Sander Land, Steven A. Niederer, Rod D. Hose, Nicolas Smith |
IEEE Trans. Medical Imaging | 1 |
| 2012 | A finite-element approach to the direct computation of relative cardiovascular pressure from time-resolved MR velocity dataabstractThe evaluation of cardiovascular velocities, their changes through the cardiac cycle and the consequent pressure gradients has the capacity to improve understanding of subject-specific blood flow in relation to adjacent soft tissue movements. Magnetic resonance time-resolved 3D phase contrast velocity acquisitions (4D flow) represent an emerging technology capable of measuring the cyclic changes of large scale, multi-directional, subject-specific blood flow. A subsequent evaluation of pressure differences in enclosed vascular compartments is a further step which is currently not directly available from such data. The focus of this work is to address this deficiency through the development of a novel simulation workflow for the direct computation of relative cardiovascular pressure fields. Input information is provided by enhanced 4D flow data and derived MR domain masking. The underlying methodology shows numerical advantages in terms of robustness, global domain composition, the isolation of local fluid compartments and a treatment of boundary conditions. This approach is demonstrated across a range of validation examples which are compared with analytic solutions. Four subject-specific test cases are subsequently run, showing good agreement with previously published calculations of intra-vascular pressure differences. The computational engine presented in this work contributes to non-invasive access to relative pressure fields, incorporates the effects of both blood flow acceleration and viscous dissipation, and enables enhanced evaluation of cardiovascular blood flow. Sebastian Krittian, Pablo Lamata, Christian Michler, David Nordsletten, Jelena Bock, Chris P. Bradley, Alex Pitcher, Philip J. Kilner, Michael Markl 0001, Nicolas Smith |
Medical Image Anal. | 2 |
| 2011 | Collaborative co-design of emerging multi-technologies for surgery
Adinda Freudenthal, Thomas Stüdeli, Pablo Lamata, Eigil Samset |
J. Biomed. Informatics | 3 |
| 2011 | An accurate, fast and robust method to generate patient-specific cubic Hermite meshes
Pablo Lamata, Steven A. Niederer, David Nordsletten, David C. Barber, Ishani Roy, Rod D. Hose, Nicolas Smith |
Medical Image Anal. | 1 |
| 2010 | Personalization of Cubic Hermite Meshes for Efficient Biomechanical Simulations
Pablo Lamata, Steven A. Niederer, David C. Barber, David Nordsletten, Jack Lee, Rod D. Hose, Nicolas Smith |
MICCAI (2) | 1 |
| 2003 | A registration-based approach to quantify Flow-Mediated Dilation (FMD) of the brachial artery in ultrasound image sequencesabstractFlow-mediated dilation (FMD) offers a mechanism to characterize endothelial function and, therefore, may play a role in the diagnosis of cardiovascular diseases. Computerized analysis techniques are very desirable to give accuracy and objectivity to the measurements. Virtually all methods proposed up to now to measure FMD rely on accurate edge detection of the arterial wall, and they are not always robust in the presence of poor image quality or image artifacts. A novel method for automatic dilation assessment based on a global image analysis strategy is presented. We model interframe arterial dilation as a superposition of a rigid motion and a scaling factor perpendicular to the artery. Rigid motion can be interpreted as a global compensation for patient and probe movements, an aspect that has not been sufficiently studied before. The scaling factor explains arterial dilation. The ultrasound sequence is analyzed in two phases using image registration to recover both transformation models. Temporal continuity in the registration parameters along the sequence is enforced with a Kalman filter since the dilation process is known to be a gradual physiological phenomenon. Comparing automated and gold standard measurements (average of manual measurements) we found a negligible bias (0.05%FMD) and a small standard deviation (SD) of the differences (1.05%FMD). These values are comparable with those obtained from manual measurements (bias = 0.23%FMD, SD(intra-obs) = 1.13%FMD, SD(inter-obs) 1.20%FMD). The proposed method offers also better reproducibility (CV = 0.40%) than the manual measurements (CV = 1.04%). Alejandro F. Frangi, Martín Laclaustra, Pablo Lamata |
IEEE Trans. Medical Imaging | 3 |