Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Hongseok Kee

dblp:43/1083 · DBLP profile ↗
← Back
1ranked-venue papers
0as first author
0since 2021 · last 2001
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 1Systems, architecture and hardware · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Computer architecture, parallel and distributed computing, and storage systems
1 paper
Integrated circuit design · 50% Embedded and real-time systems · 50%
Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%

Topics — the 2 heaviest of 3, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Integrated circuit design
analog and mixed-signal circuits
0.012001
Design and Analysis of an Electromagnetically Driven Valve for a Glaucoma Implant · ICRA 2001
Embedded and real-time systems › actuator design
electromagnetic actuator design
0.012001
Design and Analysis of an Electromagnetically Driven Valve for a Glaucoma Implant · ICRA 2001

Methods — techniques the papers use, named apart from their topics

optimal design · 0.1electromagnetic simulation · 0.1bond graph analysis · 0.1
YearPublicationVenuePosition
2001 Design and Analysis of an Electromagnetically Driven Valve for a Glaucoma Implant
abstract
Though conventional implants have a capability of pressure regulation, they cannot maintain the intra-ocular pressure (IOP) desired for different patients. To solve these problems, an active glaucoma implant which consists of the valve actuator, pressure sensor, controller, and power supply, has been developed. In this paper, we first analyse of the operation of the conventional implant using a bond graph, and show its defects and limitations of the conventional valve analytically. Next, we design and analyze an electromagnetically driven valve actuator composed of a membrane, air-core solenoid, permanent magnet, and covering frame. To save the electrical power for operating the valve actuator, appropriate actuating methods are suggested and an optimal design of the valve actuator is carried out. Finally, using simulations, the possibility of the proposed valve actuator is investigated.
Byunghoon Bae, Nakhoon Kim, Hongseok Kee, Yeon Lee, Kyihwan Park
ICRA3