Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Alexis Roche

dblp:44/2190 · DBLP profile ↗
← Back
26ranked-venue papers
10as first author
0since 2021 · last 2017
0000-0002-4821-6893ORCID · verified

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 24 · 9 first-authorGraphics, computer vision, multimedia, augmented reality and games · 17 · 7 first-authorArtificial intelligence and machine learning · 2 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%
Computer graphics and multimedia
1 paper
Image and video processing · 100%

Topics — the 4 heaviest of 4, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics › medical imaging › medical image analysis
brain image registration
0.012000
Multimodal Elastic Matching of Brain Images · ECCV (2) 2000
Medical and health informatics › medical imaging
medical image analysis
0.012000
Multimodal Elastic Matching of Brain Images · ECCV (2) 2000
Image and video processing › image registration
elastic matching
0.012000
Multimodal Elastic Matching of Brain Images · ECCV (2) 2000
Image and video processing
image registration
0.012000
Multimodal Elastic Matching of Brain Images · ECCV (2) 2000
YearPublicationVenuePosition
2017 Segmentation of Cortical and Subcortical Multiple Sclerosis Lesions Based on Constrained Partial Volume Modeling
Mário João Fartaria, Alexis Roche, Reto Meuli, Cristina Granziera, Tobias Kober, Meritxell Bach Cuadra
MICCAI (3)2
2014 Partial Volume Estimation in Brain MRI Revisited
Alexis Roche, Florence Forbes
MICCAI (1)1
2012 Closed-Form Relaxation for MRF-MAP Tissue Classification Using Discrete Laplace Equations
Alexis Roche
MICCAI (2)1
2011 On the convergence of EM-like algorithms for image segmentation using Markov random fields
Alexis Roche, Delphine Ribes Lemay, Meritxell Bach Cuadra, Gunnar Krueger
Medical Image Anal.1
2011 A Four-Dimensional Registration Algorithm With Application to Joint Correction of Motion and Slice Timing in fMRI
abstract
Existing groupwise image registration algorithms for longitudinal data generally ignore continuous movements and signal changes that occur throughout image acquisition. We emphasize the case of functional magnetic resonance images, which present spatio-temporal distortion due to the combination of head motion during scanning and staggered slice acquisition. While there exist techniques to correct for motion and slice timing separately, a common dilemma is to determine which correction should be applied first. This paper proposes a four-dimensional realignment algorithm to perform both tasks simultaneously. Experiments conducted on simulated datasets with known movements suggest that the proposed algorithm provides more accurate image reconstruction than the classical two-step realignment procedure (temporal then spatial) as implemented, for instance, in the statistical parametric mapping software.
Alexis Roche
IEEE Trans. Medical Imaging1
2009 Anatomically Informed Bayesian Model Selection for fMRI Group Data Analysis
Merlin Keller, Marc Lavielle, Matthieu Perrot, Alexis Roche
MICCAI (1)4
2008 Anatomy-Preserving Nonlinear Registration of Deep Brain ROIs Using Confidence-Based Block-Matching
Manik Bhattacharjee, Alain Pitiot, Alexis Roche, Didier Dormont, Éric Bardinet
MICCAI (2)3
2008 Real-time MR diffusion tensor and Q-ball imaging using Kalman filtering
Cyril Poupon, Alexis Roche, Jessica Dubois, Jean-François Mangin, Fabrice Poupon
Medical Image Anal.2
2007 Real-Time MR Diffusion Tensor and Q-Ball Imaging Using Kalman Filtering
Cyril Poupon, Fabrice Poupon, Alexis Roche, Yann Cointepas, Jessica Dubois, Jean-François Mangin
MICCAI (1)3
2007 Classification Based on Cortical Folding Patterns
abstract
We describe here a classification system based on automatically identified cortical sulci. Multivariate recognition methods are required for the detection of complex brain patterns with a spatial distribution. However, such methods may face the well-known issue of the curse of dimensionality-the risk of overfitting the training dataset in high-dimensional space. We overcame this problem, using a classifier pipeline with one- or two-stage of descriptor selection based on machine-learning methods, followed by a support vector machine classifier or linear discriminant analysis. We compared alternative designs of the pipeline on two different datasets built from the same database corresponding to 151 brains. The first dataset dealt with cortex asymmetry and the second dealt with the effect of the subject's sex. Our system successfully (98%) distinguished between the left and right hemispheres on the basis of sulcal shape (size, depth, etc.). The sex of the subject could be determined with a success rate of 85%. These results highlight the attractiveness of multivariate recognition models combined with appropriate descriptor selection. The sulci selected by the pipeline are consistent with previous whole-brain studies on sex effects and hemispheric asymmetries.
Edouard Duchesnay, Arnaud Cachia, Alexis Roche, Denis Rivière, Yann Cointepas, Dimitri Papadopoulos Orfanos, Monica Zilbovicius, Jean-Luc Martinot, Jean Régis, Jean-François Mangin
IEEE Trans. Medical Imaging3
2007 Structural Analysis of fMRI Data Revisited: Improving the Sensitivity and Reliability of fMRI Group Studies
abstract
Group studies of functional magnetic resonance imaging datasets are usually based on the computation of the mean signal across subjects at each voxel (random effects analyses), assuming that all subjects have been set in the same anatomical space (normalization). Although this approach allows for a correct specificity (rate of false detections), it is not very efficient for three reasons: i) its underlying hypotheses, perfect coregistration of the individual datasets and normality of the measured signal at the group level are frequently violated; ii) the group size is small in general, so that asymptotic approximations on the parameters distributions do not hold; iii) the large size of the images requires some conservative strategies to control the false detection rate, at the risk of increasing the number of false negatives. Given that it is still very challenging to build generative or parametric models of intersubject variability, we rely on a rule based, bottom-up approach: we present a set of procedures that detect structures of interest from each subject's data, then search for correspondences across subjects and outline the most reproducible activation regions in the group studied. This framework enables a strict control on the number of false detections. It is shown here that this analysis demonstrates increased validity and improves both the sensitivity and reliability of group analyses compared with standard methods. Moreover, it directly provides information on the spatial position correspondence or variability of the activated regions across subjects, which is difficult to obtain in standard voxel-based analyses.
Bertrand Thirion, Philippe Pinel, Alan Tucholka, Alexis Roche, Philippe Ciuciu, Jean-François Mangin, Jean-Baptiste Poline
IEEE Trans. Medical Imaging4
2004 Solving Incrementally the Fitting and Detection Problems in fMRI Time Series
Alexis Roche, Philippe Pinel, Stanislas Dehaene, Jean-Baptiste Poline
MICCAI (2)1
2002 A Posteriori Validation of Pre-operative Planning in Functional Neurosurgery by Quantification of Brain Pneumocephalus
Éric Bardinet, Pascal Cathier, Alexis Roche, Nicholas Ayache, Didier Dormont
MICCAI (1)3
2002 What is the best similarity measure for motion correction in fMRI time series?
abstract
It has been shown that the difference of squares cost function used by standard realignment packages (SPM and AIR) can lead to the detection of spurious activations, because the motion parameter estimations are biased by the activated areas. Therefore, this paper describes several experiments aiming at selecting a better similarity measure to drive functional magnetic resonance image registration. The behaviors of the Geman-McClure (GM) estimator, of the correlation ratio, and of the mutual information (MI) relative to activated areas are studied using simulated time series and actual data stemming from a 3T magnet. It is shown that these methods are more robust than the usual difference of squares measure. The results suggest also that the measures built from robust metrics like the GM estimator may be the best choice, while MI is also an interesting solution. Some more work, however, is required to compare the various robust metrics proposed in the literature.
Luis Freire, Alexis Roche, Jean-François Mangin
IEEE Trans. Medical Imaging2
2001 Registration of Reconstructed Post Mortem Optical Data with MR Scans of the Same Patient
Éric Bardinet, Alan C. F. Colchester, Alexis Roche, Yonggen Zhu, Sébastien Ourselin, William H. Nailon, S. Ali Hojjat 0001, James Ironside, Safa Al-Sarraj, Nicholas Ayache, Joanna M. Wardlaw
MICCAI3
2001 Rigid Point-Surface Registration Using an EM Variant of ICP for Computer Guided Oral Implantology
Sébastien Granger, Xavier Pennec, Alexis Roche
MICCAI3
2001 Fusion of Histological Sections and MR Images: Towards the Construction of an Atlas of the Human Basal Ganglia
Sébastien Ourselin, Éric Bardinet, Didier Dormont, Grégoire Malandain, Alexis Roche, Nicholas Ayache, Dominique Tandé, K. Parain, Jérôme Yelnik
MICCAI5
2001 Reconstructing a 3D structure from serial histological sections
Sébastien Ourselin, Alexis Roche, Gérard Subsol, Xavier Pennec, Nicholas Ayache
Image Vis. Comput.2
2001 Three-Dimensional Multimodal Brain Warping using the Demons Algorithm and Adaptive Intensity Corrections
abstract
This paper presents an original method for three-dimensional elastic registration of multimodal images. We propose to make use of a scheme that iterates between correcting for intensity differences between images and performing standard monomodal registration. The core of our contribution resides in providing a method that finds the transformation that maps the intensities of one image to those of another. It makes the assumption that there are at most two functional dependencies between the intensities of structures present in the images to register, and relies on robust estimation techniques to evaluate these functions. We provide results showing successful registration between several imaging modalities involving segmentations, T1 magnetic resonance (MR), T2 MR, proton density (PD) MR and computed tomography (CT). We also argue that our intensity modeling may be more appropriate than mutual information (MI) in the context of evaluating high-dimensional deformations, as it puts more constraints on the parameters to be estimated and, thus, permits a better search of the parameter space.
Alexandre Guimond, Alexis Roche, Nicholas Ayache, Jean Meunier
IEEE Trans. Medical Imaging2
2001 Rigid Registration of 3D Ultrasound with MR Images: A New Approach Combining Intensity and Gradient Information
abstract
We present a new image-based technique to rigidly register intraoperative three-dimensional ultrasound (US) with preoperative magnetic resonance (MR) images. Automatic registration is achieved by maximization of a similarity measure which generalizes the correlation ratio, and whose novelty is to incorporate multivariate information from the MR data (intensity and gradient). In addition, the similarity measure is built upon a robust intensity-based distance measure, which makes it possible to handle a variety of US artifacts. A cross-validation study has been carried out using a number of phantom and clinical data. This indicates that the method is quite robust and that the worst registration errors are of the order of the MR image resolution.
Alexis Roche, Xavier Pennec, Grégoire Malandain, Nicholas Ayache
IEEE Trans. Medical Imaging1
2000 Multimodal Elastic Matching of Brain Images
Alexis Roche, Alexandre Guimond, Nicholas Ayache, Jean Meunier
ECCV (2)1
2000 3-D Reconstruction of Macroscopic Optical Brain Slice Images
Alan C. F. Colchester, Sébastien Ourselin, Yonggen Zhu, Éric Bardinet, Alexis Roche, Safa Al-Sarraj, William H. Nailon, James Ironside, Nicholas Ayache
MICCAI6
2000 Block Matching: A General Framework to Improve Robustness of Rigid Registration of Medical Images
Sébastien Ourselin, Alexis Roche, Sylvain Prima, Nicholas Ayache
MICCAI2
2000 Generalized Correlation Ratio for Rigid Registration of 3D Ultrasound with MR Images
Alexis Roche, Xavier Pennec, Michael Rudolph 0003, Dorothee Auer, Grégoire Malandain, Sébastien Ourselin, Ludwig M. Auer, Nicholas Ayache
MICCAI1
1999 Towards a Better Comprehension of Similarity Measures Used in Medical Image Registration
Alexis Roche, Grégoire Malandain, Nicholas Ayache, Sylvain Prima
MICCAI1
1998 The Correlation Ratio as a New Similarity Measure for Multimodal Image Registration
Alexis Roche, Grégoire Malandain, Xavier Pennec, Nicholas Ayache
MICCAI1