VLDB 2026 Research / reviewers in the wild / expert
Gernot Plank
dblp:58/6821
· DBLP profile ↗
18ranked-venue papers
0as first author
12since 2021 · last 2026
0000-0002-7380-6908ORCID · conflict
Domains — the database's venue-derived domains; a paper can count in several
Applied, interdisciplinary, general and emerging computing · 17 · 12 since 2021Systems, architecture and hardware · 1
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2026 | Recovering intrinsic conduction velocity and action potential duration from electroanatomic mapping data using curvatureabstractElectroanatomic mapping systems measure the spread of activation and recovery over the surface of the heart. Propagation in cardiac tissue is complicated by the tissue architecture which produces a spatially varying anisotropic conductivity, leading to complex wavefronts. Curvature of the wavefront is known to affect both conduction velocity (CV) and action potential duration (APD). In this study, we sought to better define the impact of wavefront curvature on these properties, as well as the influence of conductivity, in order to recover intrinsic tissue properties. The dependence of CV and APD on curvature were measured for positive and negative curvatures for several ionic models, and then verified in realistic 2D and 3D simulations. Clinical data were also analysed. Results indicate that the effects of APD and CV are well described by simple formulae, and if the structure of the fibre is known, the intrinsic propagation velocities can be recovered. Geometrical curvature, as determined strictly by wavefront shape and ignoring the fibre structure, leads to large regions of spurious high curvature. This is important for determining pathological zones of slow conduction. In the simulations studied, curvature modulated APD by at most 20 ms. • New expression for influence of wavefront curvature on action potential duration. • Conduction velocity dependence on curvature for several cardiac cell models shown. • Method to find intrinsic values from measured ones, independent of activation origin. • Curvature broken down into geometrical and anisotropic components. Caroline H. Roney, Gernot Plank, Shohreh Honarbakhsh, Caterina Vidal Horrach, Simone Pezzuto, Edward J. Vigmond |
Medical Image Anal. | 2 |
| 2026 | An efficient end-to-end computational framework for the generation of ECG calibrated volumetric models of human atrial electrophysiologyabstractComputational models of atrial electrophysiology (EP) are increasingly utilized for applications such as the development of advanced mapping systems, personalized clinical therapy planning, and the generation of virtual cohorts and digital twins. These models have the potential to establish robust causal links between simulated in silico behaviors and observed human atrial EP, enabling safer, cost-effective, and comprehensive exploration of atrial dynamics. However, current state-of-the-art approaches lack the fidelity and scalability required for regulatory-grade applications, particularly in creating high-quality virtual cohorts or patient-specific digital twins. Challenges include anatomically accurate model generation, calibration to sparse and uncertain clinical data, and computational efficiency within a streamlined workflow. This study addresses these limitations by introducing novel methodologies integrated into an automated end-to-end workflow for generating high-fidelity digital twin snapshots and virtual cohorts of atrial EP. These innovations include: (i) automated multi-scale generation of volumetric biatrial models with detailed anatomical structures and fiber architecture; (ii) a robust method for defining space-varying atrial parameter fields; (iii) a parametric approach for modeling inter-atrial conduction pathways; and (iv) an efficient forward EP model for high-fidelity electrocardiogram computation. We evaluated this workflow on a cohort of 50 atrial fibrillation patients, producing high-quality meshes suitable for reaction-eikonal and reaction-diffusion models and demonstrating the ability to simulate atrial ECGs under parametrically controlled conditions. These advancements represent a critical step toward scalable, precise, and clinically applicable digital twin models and virtual cohorts, enabling enhanced patient-specific predictions and therapeutic planning. Elena Zappon, Luca Azzolin, Matthias A. F. Gsell, Franz Thaler, Anton J. Prassl, Robert Arnold, Karli Gillette, Mohammadreza Kariman, Martin Manninger, Daniel Scherr, Aurel Neic, Martin Urschler, Christoph M. Augustin, Edward J. Vigmond, Gernot Plank |
Medical Image Anal. | 15 |
| 2025 | Simulation-free prediction of atrial fibrillation inducibility with the fibrotic kernel signature
Tomás Banduc, Luca Azzolin, Martin Manninger, Daniel Scherr, Gernot Plank, Simone Pezzuto, Francisco Sahli Costabal |
Medical Image Anal. | 5 |
| 2025 | Accurate and efficient cardiac digital twin from surface ECGs: Insights into identifiability of ventricular conduction systemabstractDigital twins for cardiac electrophysiology are an enabling technology for precision cardiology. Current forward models are advanced enough to simulate the cardiac electric activity under different pathophysiological conditions and accurately replicate clinical signals like torso electrocardiograms (ECGs). In this work, we address the challenge of matching subject-specific QRS complexes using anatomically accurate, physiologically grounded cardiac digital twins. By fitting the initial conditions of a cardiac propagation model, our non-invasive method predicts activation patterns during sinus rhythm. For the first time, we demonstrate that distinct activation maps can generate identical surface ECGs. To address this non-uniqueness, we introduce a physiological prior based on the distribution of Purkinje-muscle junctions. Additionally, we develop a digital twin ensemble for probabilistic inference of cardiac activation. Our approach marks a significant advancement in the calibration of cardiac digital twins and enhances their credibility for clinical application. Thomas Grandits, Karli Gillette, Gernot Plank, Simone Pezzuto |
Medical Image Anal. | 3 |
| 2025 | Regional heterogeneity in left atrial stiffness impacts passive deformation in a cohort of patient-specific modelsabstractIn atrial fibrillation (AF), atrial biomechanics are altered, reducing atrial movement. It remains unclear whether these changes are due to altered anatomy, myocardial stiffness, or constraints from surrounding structures. Understanding the causes of changed atrial deformation in AF could enhance tissue characterization and inform AF diagnosis, stratification, and treatment. We created patient-specific anatomical models of the left atrium (LA) from CT images. Passive LA biomechanics were simulated using finite deformation continuum mechanics equations. LA stiffness was represented by the Guccione material law, where α scaled the anisotropic stiffness parameters. Regional passive stiffness parameters were calibrated to peak regional deformation during the reservoir phase and validated against deformation transients derived from retrospective gated CT images during the reservoir and conduit phase. Physiological LA deformation varies regionally, with the roof deforming significantly less than other regions during the reservoir phase. The fitted model matched peak patient deformations globally and regionally with an average error of [Formula: see text] mm over our cohort. We compared deformation transients through the reservoir and conduit phases and found that the simulated deformation transients were within an average of [Formula: see text] mm per unit time of the CT-derived deformation transients. Regional stiffness varied across the atria with average α values of 1.8, 1.6, 2.2, 1.6 and 2.1 across the cohort in the anterior, posterior, septum, lateral and roof regions respectively. Using mixed effect models, we found no correlation between regional patient LA deformation and regional estimates of wall thickness or regional volumes of epicardial adipose tissue. We found a significant correlation between regionally calibrated stiffness and CT-derived LA biomechanics (p = 0.023). We have shown that regional heterogeneity in stiffness contributes to regional LA biomechanics, while anatomical features appeared less important. These findings provide insight into the underlying causes of altered LA biomechanics in AF. Tiffany M. G. Baptiste, Cristóbal Rodero, Charles Sillett, Marina Strocchi, Christopher W. Lanyon, Christoph M. Augustin, Angela W. C. Lee, José Alonso Solís-Lemus, Caroline H. Roney, Daniel B. Ennis, Ronak Rajani, C. Aldo Rinaldi, Gernot Plank, Richard Wilkinson, Steven Williams 0001, Steven A. Niederer |
PLoS Comput. Biol. | 13 |
| 2024 | Hybrid Neural State-Space Modeling for Supervised and Unsupervised Electrocardiographic ImagingabstractState-space modeling (SSM) provides a general framework for many image reconstruction tasks. Error in a priori physiological knowledge of the imaging physics, can bring incorrectness to solutions. Modern deep-learning approaches show great promise but lack interpretability and rely on large amounts of labeled data. In this paper, we present a novel hybrid SSM framework for electrocardiographic imaging (ECGI) to leverage the advantage of state-space formulations in data-driven learning. We first leverage the physics-based forward operator to supervise the learning. We then introduce neural modeling of the transition function and the associated Bayesian filtering strategy. We applied the hybrid SSM framework to reconstruct electrical activity on the heart surface from body-surface potentials. In unsupervised settings of both in-silico and in-vivo data without cardiac electrical activity as the ground truth to supervise the learning, we demonstrated improved ECGI performances of the hybrid SSM framework trained from a small number of ECG observations in comparison to the fixed SSM. We further demonstrated that, when in-silico simulation data becomes available, mixed supervised and unsupervised training of the hybrid SSM achieved a further 40.6% and 45.6% improvements, respectively, in comparison to traditional ECGI baselines and supervised data-driven ECGI baselines for localizing the origin of ventricular activations in real data. Xiajun Jiang, Ryan Missel, Maryam Toloubidokhti, Karli Gillette, Anton J. Prassl, Gernot Plank, B. Milan Horácek, John L. Sapp |
IEEE Trans. Medical Imaging | 6 |
| 2023 | Cell to whole organ global sensitivity analysis on a four-chamber heart electromechanics model using Gaussian processes emulatorsabstractCardiac pump function arises from a series of highly orchestrated events across multiple scales. Computational electromechanics can encode these events in physics-constrained models. However, the large number of parameters in these models has made the systematic study of the link between cellular, tissue, and organ scale parameters to whole heart physiology challenging. A patient-specific anatomical heart model, or digital twin, was created. Cellular ionic dynamics and contraction were simulated with the Courtemanche-Land and the ToR-ORd-Land models for the atria and the ventricles, respectively. Whole heart contraction was coupled with the circulatory system, simulated with CircAdapt, while accounting for the effect of the pericardium on cardiac motion. The four-chamber electromechanics framework resulted in 117 parameters of interest. The model was broken into five hierarchical sub-models: tissue electrophysiology, ToR-ORd-Land model, Courtemanche-Land model, passive mechanics and CircAdapt. For each sub-model, we trained Gaussian processes emulators (GPEs) that were then used to perform a global sensitivity analysis (GSA) to retain parameters explaining 90% of the total sensitivity for subsequent analysis. We identified 45 out of 117 parameters that were important for whole heart function. We performed a GSA over these 45 parameters and identified the systemic and pulmonary peripheral resistance as being critical parameters for a wide range of volumetric and hemodynamic cardiac indexes across all four chambers. We have shown that GPEs provide a robust method for mapping between cellular properties and clinical measurements. This could be applied to identify parameters that can be calibrated in patient-specific models or digital twins, and to link cellular function to clinical indexes. Marina Strocchi, Stefano Longobardi, Christoph M. Augustin, Matthias A. F. Gsell, Argyrios Petras, C. Aldo Rinaldi, Edward J. Vigmond, Gernot Plank, Chris J. Oates, Richard Wilkinson, Steven A. Niederer |
PLoS Comput. Biol. | 8 |
| 2022 | An automated near-real time computational method for induction and treatment of scar-related ventricular tachycardiasabstractCatheter ablation is currently the only curative treatment for scar-related ventricular tachycardias (VTs). However, not only are ablation procedures long, with relatively high risk, but success rates are punitively low, with frequent VT recurrence. Personalized in-silico approaches have the opportunity to address these limitations. However, state-of-the-art reaction diffusion (R-D) simulations of VT induction and subsequent circuits used for in-silico ablation target identification require long execution times, along with vast computational resources, which are incompatible with the clinical workflow. Here, we present the Virtual Induction and Treatment of Arrhythmias (VITA), a novel, rapid and fully automated computational approach that uses reaction-Eikonal methodology to induce VT and identify subsequent ablation targets. The rationale for VITA is based on finding isosurfaces associated with an activation wavefront that splits in the ventricles due to the presence of an isolated isthmus of conduction within the scar; once identified, each isthmus may be assessed for their vulnerability to sustain a reentrant circuit, and the corresponding exit site automatically identified for potential ablation targeting. VITA was tested on a virtual cohort of 7 post-infarcted porcine hearts and the results compared to R-D simulations. Using only a standard desktop machine, VITA could detect all scar-related VTs, simulating activation time maps and ECGs (for clinical comparison) as well as computing ablation targets in 48 minutes. The comparable VTs probed by the R-D simulations took 68.5 hours on 256 cores of high-performance computing infrastructure. The set of lesions computed by VITA was shown to render the ventricular model VT-free. VITA could be used in near real-time as a complementary modality aiding in clinical decision-making in the treatment of post-infarction VTs. Fernando Otaviano Campos, Aurel Neic, Caroline Mendonça Costa, John Whitaker, Mark D. O'Neill, Reza Razavi, C. Aldo Rinaldi, DanielScherr, Steven A. Niederer, Gernot Plank, Martin J. Bishop 0001 |
Medical Image Anal. | 10 |
| 2022 | Modelling the interaction between stem cells derived cardiomyocytes patches and host myocardium to aid non-arrhythmic engineered heart tissue designabstractApplication of epicardial patches constructed from human-induced pluripotent stem cell- derived cardiomyocytes (hiPSC-CMs) has been proposed as a long-term therapy to treat scarred hearts post myocardial infarction (MI). Understanding electrical interaction between engineered heart tissue patches (EHT) and host myocardium represents a key step toward a successful patch engraftment. EHT retain different electrical properties with respect to the host heart tissue due to the hiPSC-CMs immature phenotype, which may lead to increased arrhythmia risk. We developed a modelling framework to examine the influence of patch design on electrical activation at the engraftment site. We performed an in silico investigation of different patch design approaches to restore pre-MI activation properties and evaluated the associated arrhythmic risk. We developed an in silico cardiac electrophysiology model of a transmural cross section of host myocardium. The model featured an infarct region, an epicardial patch spanning the infarct region and a bath region. The patch is modelled as a layer of hiPSC-CM, combined with a layer of conductive polymer (CP). Tissue and patch geometrical dimensions and conductivities were incorporated through 10 modifiable model parameters. We validated our model against 4 independent experimental studies and showed that it can qualitatively reproduce their findings. We performed a global sensitivity analysis (GSA) to isolate the most important parameters, showing that the stimulus propagation is mainly governed by the scar depth, radius and conductivity when the scar is not transmural, and by the EHT patch conductivity when the scar is transmural. We assessed the relevance of small animal studies to humans by comparing simulations of rat, rabbit and human myocardium. We found that stimulus propagation paths and GSA sensitivity indices are consistent across species. We explored which EHT design variables have the potential to restore physiological propagation. Simulations predict that increasing EHT conductivity from 0.28 to 1-1.1 S/m recovered physiological activation in rat, rabbit and human. Finally, we assessed arrhythmia risk related to increasing EHT conductivity and tested increasing the EHT Na+ channel density as an alternative strategy to match healthy activation. Our results revealed a greater arrhythmia risk linked to increased EHT conductivity compared to increased Na+ channel density. We demonstrated that our modeling framework could capture the interaction between host and EHT patches observed in in vitro experiments. We showed that large (patch and tissue dimensions) and small (cardiac myocyte electrophysiology) scale differences between small animals and humans do not alter EHT patch effect on infarcted tissue. Our model revealed that only when the scar is transmural do EHT properties impact activation times and isolated the EHT conductivity as the main parameter influencing propagation. We predicted that restoring physiological activation by tuning EHT conductivity is possible but may promote arrhythmic behavior. Finally, our model suggests that acting on hiPSC-CMs low action potential upstroke velocity and lack of IK1 may restore pre-MI activation while not promoting arrhythmia. Damiano Fassina, Caroline Mendonça Costa, Stefano Longobardi, Elias Karabelas, Gernot Plank, Sian E. Harding, Steven A. Niederer |
PLoS Comput. Biol. | 5 |
| 2022 | Correction: Linking statistical shape models and simulated function in the healthy adult human heartabstract[This corrects the article DOI: 10.1371/journal.pcbi.1008851.]. Cristóbal Rodero, Marina Strocchi, Maciej Marciniak, Stefano Longobardi, John Whitaker, Mark D. O'Neill, Karli Gillette, Christoph M. Augustin, Gernot Plank, Edward J. Vigmond, Pablo Lamata, Steven A. Niederer |
PLoS Comput. Biol. | 9 |
| 2021 | A Framework for the generation of digital twins of cardiac electrophysiology from clinical 12-leads ECGsabstractCardiac digital twins (Cardiac Digital Twin (CDT)s) of human electrophysiology (Electrophysiology (EP)) are digital replicas of patient hearts derived from clinical data that match like-for-like all available clinical observations. Due to their inherent predictive potential, CDTs show high promise as a complementary modality aiding in clinical decision making and also in the cost-effective, safe and ethical testing of novel EP device therapies. However, current workflows for both the anatomical and functional twinning phases within CDT generation, referring to the inference of model anatomy and parameters from clinical data, are not sufficiently efficient, robust and accurate for advanced clinical and industrial applications. Our study addresses three primary limitations impeding the routine generation of high-fidelity CDTs by introducing; a comprehensive parameter vector encapsulating all factors relating to the ventricular EP; an abstract reference frame within the model allowing the unattended manipulation of model parameter fields; a novel fast-forward electrocardiogram (Electrocardiogram (ECG)) model for efficient and bio-physically-detailed simulation required for parameter inference. A novel workflow for the generation of CDTs is then introduced as an initial proof of concept. Anatomical twinning was performed within a reasonable time compatible with clinical workflows (<4h) for 12 subjects from clinically-attained magnetic resonance images. After assessment of the underlying fast forward ECG model against a gold standard bidomain ECG model, functional twinning of optimal parameters according to a clinically-attained 12 lead ECG was then performed using a forward Saltelli sampling approach for a single subject. The achieved results in terms of efficiency and fidelity demonstrate that our workflow is well-suited and viable for generating biophysically-detailed CDTs at scale. Karli Gillette, Matthias A. F. Gsell, Anton J. Prassl, Elias Karabelas, Ursula Reiter, Gert Reiter, Thomas Grandits, Christian Payer, Darko Stern, Martin Urschler, Jason D. Bayer, Christoph M. Augustin, Aurel Neic, Thomas Pock, Edward J. Vigmond, Gernot Plank |
Medical Image Anal. | 16 |
| 2021 | Linking statistical shape models and simulated function in the healthy adult human heartabstractCardiac anatomy plays a crucial role in determining cardiac function. However, there is a poor understanding of how specific and localised anatomical changes affect different cardiac functional outputs. In this work, we test the hypothesis that in a statistical shape model (SSM), the modes that are most relevant for describing anatomy are also most important for determining the output of cardiac electromechanics simulations. We made patient-specific four-chamber heart meshes (n = 20) from cardiac CT images in asymptomatic subjects and created a SSM from 19 cases. Nine modes captured 90% of the anatomical variation in the SSM. Functional simulation outputs correlated best with modes 2, 3 and 9 on average (R = 0.49 ± 0.17, 0.37 ± 0.23 and 0.34 ± 0.17 respectively). We performed a global sensitivity analysis to identify the different modes responsible for different simulated electrical and mechanical measures of cardiac function. Modes 2 and 9 were the most important for determining simulated left ventricular mechanics and pressure-derived phenotypes. Mode 2 explained 28.56 ± 16.48% and 25.5 ± 20.85, and mode 9 explained 12.1 ± 8.74% and 13.54 ± 16.91% of the variances of mechanics and pressure-derived phenotypes, respectively. Electrophysiological biomarkers were explained by the interaction of 3 ± 1 modes. In the healthy adult human heart, shape modes that explain large portions of anatomical variance do not explain equivalent levels of electromechanical functional variation. As a result, in cardiac models, representing patient anatomy using a limited number of modes of anatomical variation can cause a loss in accuracy of simulated electromechanical function. Cristóbal Rodero, Marina Strocchi, Maciej Marciniak, Stefano Longobardi, John Whitaker, Mark D. O'Neill, Karli Gillette, Christoph M. Augustin, Gernot Plank, Edward J. Vigmond, Pablo Lamata, Steven A. Niederer |
PLoS Comput. Biol. | 9 |
| 2019 | A rule-based method for predicting the electrical activation of the heart with cardiac resynchronization therapy from non-invasive clinical dataabstractBACKGROUND: Cardiac Resynchronization Therapy (CRT) is one of the few effective treatments for heart failure patients with ventricular dyssynchrony. The pacing location of the left ventricle is indicated as a determinant of CRT outcome. OBJECTIVE: Patient specific computational models allow the activation pattern following CRT implant to be predicted and this may be used to optimize CRT lead placement. METHODS: In this study, the effects of heterogeneous cardiac substrate (scar, fast endocardial conduction, slow septal conduction, functional block) on accurately predicting the electrical activation of the LV epicardium were tested to determine the minimal detail required to create a rule based model of cardiac electrophysiology. Non-invasive clinical data (CT or CMR images and 12 lead ECG) from eighteen patients from two centers were used to investigate the models. RESULTS: Validation with invasive electro-anatomical mapping data identified that computer models with fast endocardial conduction were able to predict the electrical activation with a mean distance errors of 9.2 ± 0.5 mm (CMR data) or (CT data) 7.5 ± 0.7 mm. CONCLUSION: This study identified a simple rule-based fast endocardial conduction model, built using non-invasive clinical data that can be used to rapidly and robustly predict the electrical activation of the heart. Pre-procedural prediction of the latest electrically activating region to identify the optimal LV pacing site could potentially be a useful clinical planning tool for CRT procedures. Angela W. C. Lee, Uyen Chau Nguyen, Orod Razeghi, Justin Gould, Baldeep Sidhu, Benjamin Sieniewicz, Jonathan M. Behar, M. Mafi-Rad, Gernot Plank, Frits W. Prinzen, C. Aldo Rinaldi, Kevin Vernooy, Steven A. Niederer |
Medical Image Anal. | 9 |
| 2019 | Scar shape analysis and simulated electrical instabilities in a non-ischemic dilated cardiomyopathy patient cohortabstractThis paper presents a morphological analysis of fibrotic scarring in non-ischemic dilated cardiomyopathy, and its relationship to electrical instabilities which underlie reentrant arrhythmias.Two dimensional electrophysiological simulation models were constructed from a set of 699 late gadolinium enhanced cardiac magnetic resonance images originating from 157 patients.Areas of late gadolinium enhancement (LGE) in each image were assigned one of 10 possible microstructures, which modelled the details of fibrotic scarring an order of magnitude below the MRI scan resolution.A simulated programmed electrical stimulation protocol tested each model for the possibility of generating either a transmural block or a transmural reentry.The outcomes of the simulations were compared against morphological LGE features extracted from the images.Models which blocked or reentered, grouped by microstructure, were significantly different from one another in myocardial-LGE interface length, number of components and entropy, but not in relative area and transmurality.With an unknown microstructure, transmurality alone was the best predictor of block, whereas a combination of interface length, transmurality and number of components was the best predictor of reentry in linear discriminant analysis. Author summaryNon-ischemic dilated cardiomyopathy is a disease in which the lower left chamber of the heart is abnormally large.The cause of the disease can be anything that is not a loss of blood supply to the heart.Many patients with non-ischemic dilated cardiomyopathy have scars in their hearts which can be detected with magnetic resonance imaging.These scars are thought to disrupt the flow of electricity through the heart and cause deadly rhythm Gabriel Balaban, Brian Halliday, Wenjia Bai, Bradley Porter, Carlotta Malvuccio, Pablo Lamata, C. Aldo Rinaldi, Gernot Plank, Daniel Rueckert, Sanjay K. Prasad, Martin J. Bishop 0001 |
PLoS Comput. Biol. | 8 |
| 2018 | Universal ventricular coordinates: A generic framework for describing position within the heart and transferring dataabstractBeing able to map a particular set of cardiac ventricles to a generic topologically equivalent representation has many applications, including facilitating comparison of different hearts, as well as mapping quantities and structures of interest between them. In this paper we describe Universal Ventricular Coordinates (UVC), which can be used to describe position within any biventricular heart. UVC comprise four unique coordinates that we have chosen to be intuitive, well defined, and relevant for physiological descriptions. We describe how to determine these coordinates for any volumetric mesh by illustrating how to properly assign boundary conditions and utilize solutions to Laplace's equation. Using UVC, we transferred scalar, vector, and tensor data between four unstructured ventricular meshes from three different species. Performing the mappings was very fast, on the order of a few minutes, since mesh nodes were searched in a KD tree. Distance errors in mapping mesh nodes back and forth between meshes were less than the size of an element. Analytically derived fiber directions were also mapped across meshes and compared, showing < 5° difference over most of the ventricles. The ability to transfer gradients was also demonstrated. Topologically variable structures, like papillary muscles, required further definition outside of the UVC framework. In conclusion, UVC can aid in transferring many types of data between different biventricular geometries. Jason D. Bayer, Anton J. Prassl, Ali Pashaei, Juan F. Gomez, Antonio Frontera, Aurel Neic, Gernot Plank, Edward J. Vigmond |
Medical Image Anal. | 7 |
| 2018 | A work flow to build and validate patient specific left atrium electrophysiology models from catheter measurementsabstractBiophysical models of the atrium provide a physically constrained framework for describing the current state of an atrium and allow predictions of how that atrium will respond to therapy. We propose a work flow to simulate patient specific electrophysiological heterogeneity from clinical data and validate the resulting biophysical models. In 7 patients, we recorded the atrial anatomy with an electroanatomical mapping system (St Jude Velocity); we then applied an S1-S2 electrical stimulation protocol from the coronary sinus (CS) and the high right atrium (HRA) whilst recording the activation patterns using a PentaRay catheter with 10 bipolar electrodes at 12 ± 2 sites across the atrium. Using only the activation times measured with a PentaRay catheter and caused by a stimulus applied in the CS with a remote catheter we fitted the four parameters for a modified Mitchell-Schaeffer model and the tissue conductivity to the recorded local conduction velocity restitution curve and estimated local effective refractory period. Model parameters were then interpolated across each atrium. The fitted model recapitulated the S1-S2 activation times for CS pacing giving a correlation ranging between 0.81 and 0.98. The model was validated by comparing simulated activations times with the independently recorded HRA pacing S1-S2 activation times, giving a correlation ranging between 0.65 and 0.96. The resulting work flow provides the first validated cohort of models that capture clinically measured patient specific electrophysiological heterogeneity. Cesare Corrado, Steven Williams 0001, Rashed Karim, Gernot Plank, Mark D. O'Neill, Steven A. Niederer |
Medical Image Anal. | 4 |
| 2018 | Personalized computational modeling of left atrial geometry and transmural myofiber architectureabstractAtrial fibrillation (AF) is a supraventricular tachyarrhythmia characterized by complete absence of coordinated atrial contraction and is associated with an increased morbidity and mortality. Personalized computational modeling provides a novel framework for integrating and interpreting the role of atrial electrophysiology (EP) including the underlying anatomy and microstructure in the development and sustenance of AF. Coronary computed tomography angiography data were segmented using a statistics-based approach and the smoothed voxel representations were discretized into high-resolution tetrahedral finite element (FE) meshes. To estimate the complex left atrial myofiber architecture, individual fiber fields were generated according to morphological data on the endo- and epicardial surfaces based on local solutions of Laplace's equation and transmurally interpolated to tetrahedral elements. The influence of variable transmural microstructures was quantified through EP simulations on 3 patients using 5 different fiber interpolation functions. Personalized geometrical models included the heterogeneous thickness distribution of the left atrial myocardium and subsequent discretization led to high-fidelity tetrahedral FE meshes. The novel algorithm for automated incorporation of the left atrial fiber architecture provided a realistic estimate of the atrial microstructure and was able to qualitatively capture all important fiber bundles. Consistent maximum local activation times were predicted in EP simulations using individual transmural fiber interpolation functions for each patient suggesting a negligible effect of the transmural myofiber architecture on EP. The established modeling pipeline provides a robust framework for the rapid development of personalized model cohorts accounting for detailed anatomy and microstructure and facilitates simulations of atrial EP. Thomas E. Fastl, Catalina Tobon-Gomez, Andrew Crozier, John Whitaker, Ronak Rajani, Karen P. McCarthy, Damian Sánchez-Quintana, Siew Y. Ho, Mark D. O'Neill, Gernot Plank, Martin J. Bishop 0001, Steven A. Niederer |
Medical Image Anal. | 10 |
| 2011 | Accelerating cardiac excitation spread simulations using graphics processing unitsabstractAbstract The modeling of the electrical activity of the heart is of great medical and scientific interest, because it provides a way to get a better understanding of the related biophysical phenomena, allows the development of new techniques for diagnoses and serves as a platform for drug tests. The cardiac electrophysiology may be simulated by solving a partial differential equation coupled to a system of ordinary differential equations describing the electrical behavior of the cell membrane. The numerical solution is, however, computationally demanding because of the fine temporal and spatial sampling required. The demand for real‐time high definition 3D graphics made the new graphic processing units (GPUs) a highly parallel, multithreaded, many‐core processor with tremendous computational horsepower. It makes the use of GPUs a promising alternative to simulate the electrical activity in the heart. The aim of this work is to study the performance of GPUs for solving the equations underlying the electrical activity in a simple cardiac tissue. In tests on 2D cardiac tissues with different cell models it is shown that the GPU implementation runs 20 times faster than a parallel CPU implementation running with 4 threads on a quad–core machine, parts of the code are even accelerated by a factor of 180. Copyright © 2010 John Wiley & Sons, Ltd. Bernardo M. Rocha, Fernando Otaviano Campos, Ronan M. Amorim, Gernot Plank, Rodrigo Weber dos Santos, Manfred Liebmann, Gundolf Haase |
Concurr. Comput. Pract. Exp. | 4 |