Demo Data from VLDB 2026 / reviewers in the wild / expert
Ahmet G. Cepni
dblp:67/2901
· DBLP profile ↗
8ranked-venue papers
1as first author
0since 2021 · last 2006
—ORCID · none
Domains — the database's venue-derived domains; a paper can count in several
Computer networks · 6 · 1 first-authorGraphics, computer vision, multimedia, augmented reality and games · 2
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Computer networks
2 papers |
Physical-layer communications · 88% Wireless networking · 7% Wireless sensing and localization · 5% |
Topics — the 6 heaviest of 6, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Physical-layer communications › information theory › capacity analysis
channel capacity estimation |
0.1 | 1 | 2005 | On the capacity limits of HVAC duct channel for high-speed Internet access · IEEE Trans. Commun. 2005 |
Physical-layer communications › modulation › quadrature amplitude modulation
M-QAM |
0.1 | 1 | 2005 | On the capacity limits of HVAC duct channel for high-speed Internet access · IEEE Trans. Commun. 2005 |
Physical-layer communications › modulation
multicarrier transmission |
0.1 | 1 | 2005 | On the capacity limits of HVAC duct channel for high-speed Internet access · IEEE Trans. Commun. 2005 |
Physical-layer communications
channel modeling |
0.0 | 1 | 2003 | Impulse response of the HVAC duct as a communication channel · IEEE Trans. Commun. 2003 |
Wireless networking
indoor wireless networks |
0.0 | 1 | 2005 | On the capacity limits of HVAC duct channel for high-speed Internet access · IEEE Trans. Commun. 2005 |
Wireless sensing and localization
wireless sensing |
0.0 | 1 | 2003 | Impulse response of the HVAC duct as a communication channel · IEEE Trans. Commun. 2003 |
Methods — techniques the papers use, named apart from their topics
channel measurement · 0.1testbed experiments · 0.1impulse response analysis · 0.0
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2006 | Array Processing Using Time Reversal: Experiments and PerformanceabstractIn this paper we derive the generalized likelihood ratio test (GLRT) for time reversal detection. We consider a multistatic array configuration with two antenna arrays, one for transmitting and one for receiving. We examine the time reversal GLRT performance with experimental measurements in the electromagnetic domain in a highly cluttered laboratory environment. The experiments show that time reversal provides significant performance gain over the conventional energy detector. José M. F. Moura, Yuanwei Jin, Daniel D. Stancil, Jian-Gang Zhu, Ahmet G. Cepni, Benjamin E. Henty |
ICASSP (4) | 5 |
| 2005 | Single antenna time reversal adaptive interference cancellationabstractThis paper presents the time reversal adaptive interferer canceller (TRAIC), a novel algorithm that uses time reversal techniques to cancel the presence of interferers. TRAIC is developed for broadband signals and a single emitting antenna. Experimental tests in the electromagnetic domain show the viability and the power of TRAIC. José M. F. Moura, Yuanwei Jin, Daniel D. Stancil, Jian-Gang Zhu, Ahmet G. Cepni, Benjamin E. Henty |
ICASSP (4) | 5 |
| 2005 | On the capacity limits of HVAC duct channel for high-speed Internet accessabstractIn this paper, we report theoretical and experimental channel-capacity estimates of heating, ventilation, and air conditioning (HVAC) ducts based on multicarrier transmission that uses M-ary quadrature amplitude modulation and measured channel responses at the 2.4-GHz industrial, scientific, and medical band. It is shown theoretically that data rates in excess of 1 Gb/s are possible over distances up to 500 m in straight ducts in which reflections have been suppressed. Our experimental results also show that even in the case of more complex HVAC duct networks (i.e., HVAC duct networks that include bends, tees, etc.) data rates over 2 Gb/s are possible. Our estimations in this case are valid for distances of up to 22 m, which was the maximum distance of our experimental setup. These experimental results, measured with a large-scale testbed set up at Carnegie Mellon University, Pittsburgh, PA, albeit limited in terms of transmitter-receiver separation distance, provide further evidence on the potential of HVAC systems as an attractive solution for providing communications in indoor wireless networks. Ariton E. Xhafa, Ozan K. Tonguz, Ahmet G. Cepni, Daniel D. Stancil, Pavel V. Nikitin, Dagfin Brodtkorb |
IEEE Trans. Commun. | 3 |
| 2004 | Capacity of multi-antenna array systems for HVAC ductsabstractMulti-element antenna arrays at both transmitter and receiver systems have emerged as a new technique for wireless communication systems in rich multipath environments. HVAC ducts, viewed as over-moded waveguide network systems at RF frequencies, have the multipath richness through various propagating modes and reflections within the system. This paper studies multiple-input multiple-output (MIMO) systems for HVAC ducts. Computations based on measured channel responses of a 6/spl times/6 MIMO system in 0.3 m diameter HVAC ducts in the 2.4 GHz ISM band demonstrate a five-fold increase in mean capacity over single antenna systems for an SNR of 30 dB. Ahmet G. Cepni, Daniel D. Stancil, Ariton E. Xhafa, Benjamin E. Henty, Pavel V. Nikitin, Ozan K. Tonguz, Dagfin Brodtkorb |
ICC | 1 |
| 2003 | Seamless handover in buildings using HVAC ducts: a new system architectureabstractIn this paper, we present an innovative solution to the handover problem in multi-story buildings using HVAC ducts for wireless communications. The proposed solution is based on a new system architecture design of the indoor wireless networks that use the heating, ventilation, and air conditioning (HVAC) ducts as a communication channel. Exploiting the system architecture design and the time diversity at the mobile terminal, we show that intra-floor handover can be eliminated, while inter-floor handover can be substantially reduced due to the fact that multiple floors can be served via the same access point. Our results indicate that the mean number of handovers per call achieved in the indoor wireless networks that use HVAC ducts reduces; e.g., by up to a factor of nine for the illustrative example considered in this paper compared to that of indoor wireless networks that do not use HVAC ducts. The improvement; i.e., reduction in the mean number of handovers in multi-story building, depends on the number of access points used. Ariton E. Xhafa, Paisarn Sonthikorn, Ozan K. Tonguz, Pavel V. Nikitin, Ahmet G. Cepni, Daniel D. Stancil, Benjamin E. Henty, Dagfin Brodtkorb |
GLOBECOM | 5 |
| 2003 | Impulse response of the HVAC duct as a communication channelabstractHeating, ventilation, and air conditioning (HVAC) ducts in buildings behave as multimode waveguides when excited at radio frequencies and thus, can be used to distribute radio signals. The channel properties of the ducts are different from the properties of a usual indoor propagation channel. In this paper, we describe physical mechanisms which affect the HVAC channel impulse response and analyze their influence on the delay spread. Those mechanisms include antenna coupling, attenuation, and three types of dispersion: intramodal, intermodal, and multipath. We analyze each type separately and explore the behavior of the delay spread as a function of distance in straight ducts. Experimental channel measurements taken on real ducts confirm the validity of our model. Pavel V. Nikitin, Daniel D. Stancil, Ozan K. Tonguz, Ariton E. Xhafa, Ahmet G. Cepni, Dagfin Brodtkorb |
IEEE Trans. Commun. | 5 |
| 2002 | An empirical path loss model for HVAC duct systemsabstractWe present a simple path loss prediction model for link budget analysis in indoor wireless local area networks (LANs) that use heating, ventilation, and air conditioning (HVAC) ducts. The model we propose predicts the average power at each location in an HVAC duct network. This prediction model greatly simplifies the analysis for a complex duct network, making it a convenient and simple tool for system design. Our prediction model Is verified by experimental measurements. Ozan K. Tonguz, Daniel D. Stancil, Ariton E. Xhafa, Ahmet G. Cepni, Pavel V. Nikitin, Dagfin Brodtkorb |
GLOBECOM | 4 |
| 2002 | Theoretical estimates of HVAC duct channel capacity for high-speed Internet accessabstractWe report theoretical channel capacity estimates of heating, ventilation, and air-conditioning (HVAC) ducts based on multi-carrier transmission that uses M-QAM modulation and measured channel responses at 2.4 GHz Industrial, Scientific, and Medical (ISM) band. It is shown that, data rates in excess of 1 Gbps are possible over distances up to 500 m in "matched" ducts (one can think of "matched" ducts as user-friendly ducts, since "matching" can, in principle, eliminate all the multipath reflections in HVAC ducts). Our work also shows that data rates in excess of 300 Mbps are possible over distances up to 500 m even in the presence of significant multipath reflections. Ariton E. Xhafa, Ozan K. Tonguz, Ahmet G. Cepni, Daniel D. Stancil, Pavel V. Nikitin, Dagfin Brodtkorb |
ICC | 3 |