VLDB 2026 Research / reviewers in the wild / expert
Stuart Crozier
dblp:73/5039
· DBLP profile ↗
20ranked-venue papers
0as first author
5since 2021 · last 2024
0000-0003-4036-2930ORCID · verified
Domains — the database's venue-derived domains; a paper can count in several
Applied, interdisciplinary, general and emerging computing · 14 · 4 since 2021Graphics, computer vision, multimedia, augmented reality and games · 7 · 2 since 2021Artificial intelligence and machine learning · 3Security and privacy · 1
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2024 | Automated anomaly-aware 3D segmentation of bones and cartilages in knee MR images from the Osteoarthritis InitiativeabstractIn medical image analysis, automated segmentation of multi-component anatomical entities, with the possible presence of variable anomalies or pathologies, is a challenging task. In this work, we develop a multi-step approach using U-Net-based models to initially detect anomalies (bone marrow lesions, bone cysts) in the distal femur, proximal tibia and patella from 3D magnetic resonance (MR) images in individuals with varying grades of knee osteoarthritis. Subsequently, the extracted data are used for downstream tasks involving semantic segmentation of individual bone and cartilage volumes as well as bone anomalies. For anomaly detection, U-Net-based models were developed to reconstruct bone volume profiles of the femur and tibia in images via inpainting so anomalous bone regions could be replaced with close to normal appearances. The reconstruction error was used to detect bone anomalies. An anomaly-aware segmentation network, which was compared to anomaly-naïve segmentation networks, was used to provide a final automated segmentation of the individual femoral, tibial and patellar bone and cartilage volumes from the knee MR images which contain a spectrum of bone anomalies. The anomaly-aware segmentation approach provided up to 58% reduction in Hausdorff distances for bone segmentations compared to the results from anomaly-naïve segmentation networks. In addition, the anomaly-aware networks were able to detect bone anomalies in the MR images with greater sensitivity and specificity (area under the receiver operating characteristic curve [AUC] up to 0.896) compared to anomaly-naïve segmentation networks (AUC up to 0.874). Boyeong Woo, Craig Engstrom, William Baresic, Jurgen Fripp, Stuart Crozier, Shekhar Chandra |
Medical Image Anal. | 5 |
| 2023 | Style-Based Manifold for Weakly-Supervised Disease Characteristic Discovery
Siyu Liu 0002, Linfeng Liu 0009, Craig Engstrom, Xuan Vinh To, ZongYuan Ge, Stuart Crozier, Fatima A. Nasrallah, Shekhar Chandra |
MICCAI (5) | 6 |
| 2022 | CAN3D: Fast 3D medical image segmentation via compact context aggregation
Wei Dai 0016, Boyeong Woo, Siyu Liu 0002, Matthew Marques, Craig Engstrom, Peter B. Greer, Stuart Crozier, Jason Dowling, Shekhar Chandra |
Medical Image Anal. | 7 |
| 2022 | Integrated Multi-Modal Antenna With Coupled Radiating Structures (I-MARS) for 7T pTx Body MRIabstractOne of the main challenges in ultra-high field whole body MRI relates to the uniformity and efficiency of the radiofrequency field. Although recent advances in the design of RF coils have demonstrated that dipole antennas have a current distribution ideally suited to 7T MRI, they are limited by low isolation and poor robustness to loading changes. Multi-layered and self-decoupled loop coils have demonstrated improved RF performance in these areas at lower field MRI but have not been adapted to dipole designs. In this work, we introduce a novel type of RF antenna consisting of integrated multi-modal antenna with coupled radiating structures (I-MARS), which use layered conductors and dielectric substrates to allow dipole and transmission line modes to co-exist on the same compact dipole-shaped structure. The proposed antenna was optimally designed for 7T MRI and compared with existing dipole antennas using numerical simulations, which showed that I-MARS had similar B1over specific absorption rate efficiency and superior isolation and stability. Subsequently, a prototype pTx coil array was built and testedin vivoon healthy volunteers at 7T. The articulated, modular construction of the I-MARS coil array allowed it to be readily conformed across multiple body regions (hip, knee, shoulder, lumbar spine and prostate), without requiring modification of the tuning and matching of the antennas. Using RF shimming, uniform and efficient excitation was successfully achieved in the acquisition of high-resolution MR images. Aurelien Destruel, Jin Jin 0003, Ewald Weber, Craig Engstrom, Feng Liu 0005, Stuart Crozier |
IEEE Trans. Medical Imaging | 7 |
| 2021 | Bespoke Fractal Sampling Patterns for Discrete Fourier Space via the Kaleidoscope TransformabstractSampling strategies are important for sparse imaging methodologies, especially those employing the discrete Fourier transform (DFT). Chaotic sensing is one such methodology that employs deterministic, fractal sampling in conjunction with finite, iterative reconstruction schemes to form an image from limited samples. Using a sampling pattern constructed entirely from periodic lines in DFT space, chaotic sensing was found to outperform traditional compressed sensing for magnetic resonance imaging; however, only one such sampling pattern was presented and the reason for its fractal nature was not proven. Through the introduction of a novel image transform known as the kaleidoscope transform, which formalises and extends upon the concept of downsampling and concatenating an image with itself, this paper: (1) demonstrates a fundamental relationship between multiplication in modular arithmetic and downsampling; (2) provides a rigorous mathematical explanation for the fractal nature of the sampling pattern in the DFT; and (3) leverages this understanding to develop a collection of novel fractal sampling patterns for the 2D DFT with customisable properties. The ability to design tailor-made fractal sampling patterns expands the utility of the DFT in chaotic imaging and may form the basis for a bespoke chaotic sensing methodology, in which the fractal sampling matches the imaging task for improved reconstruction. Jacob M. White 0002, Stuart Crozier, Shekhar Chandra |
IEEE Signal Process. Lett. | 2 |
| 2020 | Integral MR-EPT With the Calculation of Coil Current DistributionsabstractMany integral equation (IE)-based magnetic resonance electrical property tomography (MR-EPT) methods use unloaded incident radio-frequency (RF) fields from simulations that may not fully reflect the real situation and thus lead to reconstruction errors. To improve the accuracy of IE-based MR-EPT methods, a novel approach that enables the calculation of loaded coil current distributions and avoids the explicit use of incident RF fields is presented in this paper. In the proposed method, a hybrid source composed of the current source from the coil and the contrast source from the subject are introduced in the integral equations. Because the loaded coil current distributions can be extracted from the reconstructed hybrid source, the simulated incident RF fields are eliminated from the problem formulations. To improve the convergence performance, a modified conjugate gradient (CG) scheme was used where the gradients of the current source and contrast source were balanced through using different weighting parameters. The proposed method was verified through full-wave simulations at 9.4 and 7 T involving a heterogeneous ball and an anatomical head phantom. The numerical results indicated that by using the proposed method, an accurate coil current distributions and EPs profiles can be reconstructed and the desirable robustness against noise can also be achieved. Lei Guo 0007, Feng Liu 0005, Stuart Crozier |
IEEE Trans. Medical Imaging | 5 |
| 2018 | Chaotic SensingabstractWe propose a sparse imaging methodology called Chaotic Sensing (ChaoS) that enables the use of limited yet deterministic linear measurements through fractal sampling. A novel fractal in the discrete Fourier transform is introduced that always results in the artefacts being turbulent in nature. These chaotic artefacts have characteristics that are image independent, facilitating their removal through dampening (via image denoising) and obtaining the maximum likelihood solution. In contrast with existing methods, such as compressed sensing, the fractal sampling is based on digital periodic lines that form the basis of discrete projected views of the image without requiring additional transform domains. This allows the creation of finite iterative reconstruction schemes in recovering an image from its fractal sampling that is also new to discrete tomography. As a result, ChaoS supports linear measurement and optimisation strategies, while remaining capable of recovering a theoretically exact representation of the image. We apply the method to simulated and experimental limited magnetic resonance (MR) imaging data, where restrictions imposed by MR physics typically favour linear measurements for reducing acquisition time. Shekhar Chandra, Gary Ruben, Jin Jin 0003, Andrew Kingston, Imants D. Svalbe, Stuart Crozier |
IEEE Trans. Image Process. | 7 |
| 2014 | GPU accelerated high-dimensional compressed sensing MRIabstractRecently, we have developed a tensor-decomposition based compressed sensing (CS) method for dynamic magnetic resonance imaging (dMRI) [1]. The proposed CS-dMRI method exploits the sparsity of the multi-dimensional MRI signal using Higher-order singular value decomposition (HOSVD). Our preliminary study indicates that, compared with conventional approaches, the proposed CS method offers further acceleration in acquisition and also improves image quality. To further enhance the algorithm efficiency, in this work, we present a parallelized implementation of the HOSVD-based CS reconstructions using a graphics processing unit (GPU). The cine cardiac MRI study indicated the efficiency and accuracy of the GPU-accelerated high-dimensional CS-dMRI method. He Guo 0001, Yinxin Wang, Yeyang Yu, Yang Yang 0118, Feng Liu 0005, Stuart Crozier |
ICARCV | 7 |
| 2014 | Focused shape models for hip joint segmentation in 3D magnetic resonance images
Shekhar Chandra, Craig Engstrom, Stuart Crozier, Raphael Schwarz, Jurgen Fripp |
Medical Image Anal. | 4 |
| 2013 | Mutual information-based binarisation of multiple images of an object: an application in medical imagingabstractA new method for image thresholding of two or more images that are acquired in different modalities or acquisition protocols is proposed. The method is based on measures from information theory and has no underlying free parameters nor does it require training or calibration. The method is based on finding an optimal set of global thresholds, one for each image, by maximising the mutual information above the thresholds while minimising the mutual information below the thresholds. Although some assumptions on the nature of images are made, no assumptions are made by the method on the intensity distributions or on the shape of the image histograms. The effectiveness of the method is demonstrated both on synthetic images and medical images from clinical practice. It is then compared against three other thresholding methods Yaniv Gal, Andrew Mehnert, Stephen E. Rose, Stuart Crozier |
IET Comput. Vis. | 4 |
| 2013 | Research and applications: Three-dimensional morphological and signal intensity features for detection of intervertebral disc degeneration from magnetic resonance imagesabstractBACKGROUND AND OBJECTIVES: Advances in MRI hardware and sequences are continually increasing the amount and complexity of data such as those generated in high-resolution three-dimensional (3D) scanning of the spine. Efficient informatics tools offer considerable opportunities for research and clinically based analyses of magnetic resonance studies. In this work, we present and validate a suite of informatics tools for automated detection of degenerative changes in lumbar intervertebral discs (IVD) from both 3D isotropic and routine two-dimensional (2D) clinical T2-weighted MRI. MATERIALS AND METHODS: An automated segmentation approach was used to extract morphological (traditional 2D radiological measures and novel 3D shape descriptors) and signal appearance (extracted from signal intensity histograms) features. The features were validated against manual reference, compared between 2D and 3D MRI scans and used for quantification and classification of IVD degeneration across magnetic resonance datasets containing IVD with early and advanced stages of degeneration. RESULTS AND CONCLUSIONS: Combination of the novel 3D-based shape and signal intensity features on 3D (area under receiver operating curve (AUC) 0.984) and 2D (AUC 0.988) magnetic resonance data deliver a significant improvement in automated classification of IVD degeneration, compared to the combination of previously used 2D radiological measurement and signal intensity features (AUC 0.976 and 0.983, respectively). Further work is required regarding the usefulness of 2D and 3D shape data in relation to clinical scores of lower back pain. The results reveal the potential of the proposed informatics system for computer-aided IVD diagnosis from MRI in large-scale research studies and as a possible adjunct for clinical diagnosis. Ales Neubert, Jurgen Fripp, Craig Engstrom, Duncan Walker, Marc-André Weber, Raphael Schwarz, Stuart Crozier |
J. Am. Medical Informatics Assoc. | 7 |
| 2012 | Advanced Three-Dimensional Tailored RF Pulse Design in Volume Selective Parallel ExcitationabstractVolume selective excitation has a variety of uses in clinical magnetic resonance imaging, but can suffer from insufficient excitation accuracy and impractically long pulse duration in ultra-high field applications. Based on recently-developed parallel transmission techniques, an optimized 3D tailored radio-frequency RF (TRF) pulse, designed with a novel 3D adaptive trajectory, is proposed to improve and accelerate volume selective excitation. The trajectory is designed to be regular-shaped and adaptively stretched according to the size of a 3D k-space "trajectory container." The container is designed to hold most of the RF energy deposition responsible for the desired pattern in the excitation k-space in the use of the blurring patterns caused by the multichannel sensitivity maps. The proposed method can also be used to reduce both global and peak RF energy required during excitation. The feasibility of this method is confirmed by simulations of ultra-high field cases. Tingting Shao, Ling Xia 0001, Guisheng Tao, Jieru Chi, Feng Liu 0005, Stuart Crozier |
IEEE Trans. Medical Imaging | 6 |
| 2011 | A Reduced Order Explicit Dynamic Finite Element Algorithm for Surgical SimulationabstractReduced order modelling, in which a full system response is projected onto a subspace of lower dimensionality, has been used previously to accelerate finite element solution schemes by reducing the size of the involved linear systems. In the present work we take advantage of a secondary effect of such reduction for explicit analyses, namely that the stable integration time step is increased far beyond that of the full system. This phenomenon alleviates one of the principal drawbacks of explicit methods, compared with implicit schemes. We present an explicit finite element scheme in which time integration is performed in a reduced basis. Futhermore, we present a simple procedure for imposing inhomogeneous essential boundary conditions, thus overcoming one of the principal deficiencies of such approaches. The computational benefits of the procedure within a GPU-based execution framework are examined, and an assessment of the errors introduced is given. It is shown that speedups approaching an order of magnitude are feasible, without introduction of prohibitive errors, and without hardware modifications. The procedure may have applications in interactive simulation and medical image-guidance problems, in which both speed and accuracy are vital. Zeike A. Taylor, Stuart Crozier, Sébastien Ourselin |
IEEE Trans. Medical Imaging | 2 |
| 2010 | Real-Time Surgical Simulation Using Reduced Order Finite Element Analysis
Zeike A. Taylor, Stuart Crozier, Sébastien Ourselin |
MICCAI (2) | 2 |
| 2010 | Automatic Segmentation and Quantitative Analysis of the Articular Cartilages From Magnetic Resonance Images of the KneeabstractIn this paper, we present a segmentation scheme that automatically and accurately segments all the cartilages from magnetic resonance (MR) images of nonpathological knees. Our scheme involves the automatic segmentation of the bones using a three-dimensional active shape model, the extraction of the expected bone-cartilage interface (BCI), and cartilage segmentation from the BCI using a deformable model that utilizes localization, patient specific tissue estimation and a model of the thickness variation. The accuracy of this scheme was experimentally validated using leave one out experiments on a database of fat suppressed spoiled gradient recall MR images. The scheme was compared to three state of the art approaches, tissue classification, a modified semi-automatic watershed algorithm and nonrigid registration (B-spline based free form deformation). Our scheme obtained an average Dice similarity coefficient (DSC) of (0.83, 0.83, 0.85) for the (patellar, tibial, femoral) cartilages, while (0.82, 0.81, 0.86) was obtained with a tissue classifier and (0.73, 0.79, 0.76) was obtained with nonrigid registration. The average DSC obtained for all the cartilages using a semi-automatic watershed algorithm (0.90) was slightly higher than our approach (0.89), however unlike this approach we segment each cartilage as a separate object. The effectiveness of our approach for quantitative analysis was evaluated using volume and thickness measures with a median volume difference error of (5.92, 4.65, 5.69) and absolute Laplacian thickness difference of (0.13, 0.24, 0.12) mm. Jurgen Fripp, Stuart Crozier, Simon K. Warfield, Sébastien Ourselin |
IEEE Trans. Medical Imaging | 2 |
| 2010 | Denoising of Dynamic Contrast-Enhanced MR Images Using Dynamic Nonlocal MeansabstractThis paper presents a new algorithm for denoising dynamic contrast-enhanced (DCE) MR images. It is a novel variation on the nonlocal means (NLM) algorithm. The algorithm, called dynamic nonlocal means (DNLM), exploits the redundancy of information in the temporal sequence of images. Empirical evaluations of the performance of the DNLM algorithm relative to seven other denoising methods-simple Gaussian filtering, the original NLM algorithm, a trivial extension of NLM to include the temporal dimension, bilateral filtering, anisotropic diffusion filtering, wavelet adaptive multiscale products threshold, and traditional wavelet thresholding-are presented. The evaluations include quantitative evaluations using simulated data and real data (20 DCE-MRI data sets from routine clinical breast MRI examinations) as well as qualitative evaluations using the same real data (24 observers: 14 image/signal-processing specialists, 10 clinical breast MRI radiographers). The results of the quantitative evaluation using the simulated data show that the DNLM algorithm consistently yields the smallest MSE between the denoised image and its corresponding original noiseless version. The results of the quantitative evaluation using the real data provide evidence, at the alpha = 0.05 level of significance, that the DNLM algorithm yields the smallest MSE between the denoised image and its corresponding original noiseless version. The results of the qualitative evaluation provide evidence, at the alpha = 0.05 level of significance, that the DNLM algorithm performs visually better than all of the other algorithms. Collectively the qualitative and quantitative results suggest that the DNLM algorithm more effectively attenuates noise in DCE MR images than any of the other algorithms. Yaniv Gal, Andrew Mehnert, Andrew P. Bradley, Kerry McMahon, Dominic Kennedy, Stuart Crozier |
IEEE Trans. Medical Imaging | 6 |
| 2007 | A Comparison of DCT and DWT Block Based Watermarking on Medical Image Quality
Jason Dowling, Birgit M. Planitz, Anthony J. Maeder, Jiang Du 0002, Binh Pham 0001, Colin Boyd, Shaokang Chen, Andrew P. Bradley, Stuart Crozier |
IWDW | 9 |
| 2007 | Automatic Segmentation of Articular Cartilage in Magnetic Resonance Images of the Knee
Jurgen Fripp, Stuart Crozier, Simon K. Warfield, Sébastien Ourselin |
MICCAI (2) | 2 |
| 2005 | MRI magnet design: search space analysis, EDAs and a real-world problem with significant dependenciesabstractThis paper introduces the design of superconductive magnet configurations in Magnetic Resonance Imaging (MRI) systems as a challenging real-world problem for Evolutionary Algorithms (EAs). Analysis of the problem structure is conducted using a general statistical method, which could be easily applied to other problems. The results suggest that the problem is highly multimodal and likely to present a significant challenge for many algorithms. Through a series of preliminary experiments, a continuous Estimation of Distribution Algorithm (EDA) is shown to be able to generate promising designs with a small computational effort. The importance of utilizing problem-specific knowledge and the ability of an algorithm to capture dependencies in solving complex real-world problems is also highlighted. Bo Yuan 0003, Marcus Gallagher, Stuart Crozier |
GECCO | 3 |
| 2005 | The Use of Unwrapped Phase in MR Image Segmentation: A Preliminary Study
Pierrick Bourgeat, Jurgen Fripp, Andrew L. Janke, Graham J. Galloway, Stuart Crozier, Sébastien Ourselin |
MICCAI (2) | 5 |