Demo Data from VLDB 2026 / reviewers in the wild / expert
Michael Zervas
dblp:87/9967
· DBLP profile ↗
1ranked-venue papers
0as first author
0since 2021 · last 2011
—ORCID · none
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 1Systems, architecture and hardware · 1
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Artificial intelligence
1 paper |
Motion planning and robot control · 50% Robot manipulation · 50% | |
| Interdisciplinary, comprehensive, and emerging computing
1 paper |
Medical and health informatics · 100% |
Topics — the 3 heaviest of 3, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Robotics › Robot manipulation › medical robotics
needle steering |
0.1 | 1 | 2011 | Real-time MRI-guided needle placement robot with integrated fiber optic force sensing · ICRA 2011 |
Robotics › Motion planning and robot control
robot control |
0.1 | 1 | 2011 | Real-time MRI-guided needle placement robot with integrated fiber optic force sensing · ICRA 2011 |
Medical and health informatics › medical robotics
robot-assisted intervention |
0.0 | 1 | 2011 | Real-time MRI-guided needle placement robot with integrated fiber optic force sensing · ICRA 2011 |
Methods — techniques the papers use, named apart from their topics
piezoelectric actuation · 0.2fiber optic force sensing · 0.2fabry-perot interferometer · 0.2
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2011 | Real-time MRI-guided needle placement robot with integrated fiber optic force sensingabstractThis paper presents the first prototype of a magnetic resonance imaging (MRI) compatible piezoelectric actuated robot integrated with a high-resolution fiber optic sensor for prostate brachytherapy with real-time in situ needle steering capability in 3T MRI. The 6-degrees-of-freedom (DOF) robot consists of a modular 3-DOF needle driver with fiducial tracking frame and a 3-DOF actuated Cartesian stage. The needle driver provides needle cannula rotation and translation (2-DOF) and stylet translation (1-DOF). The driver mimics the manual physician gesture by two point grasping. To render proprioception associated with prostate interventions, a Fabry Perot interferometer based fiber optic strain sensor is designed to provide high-resolution axial needle insertion force measurement and is robust to large range of temperature variation. The paper explains the robot mechanism, controller design, optical modeling and opto-mechanical design of the force sensor. MRI compatibility of the robot is evaluated under 3T MRI using standard prostate imaging sequences and average signal noise ratio (SNR) loss is limited to 2% during actuator motion. A dynamic needle insertion is performed and bevel tip needle steering capability is demonstrated under continuous real-time MRI guidance, both with no visually identifiable interference during robot motion. Fiber optic sensor calibration validates the theoretical modeling with satisfactory sensing range and resolution for prostate intervention. Hao Su 0002, Michael Zervas, Gregory A. Cole, Cosme Furlong, Gregory S. Fischer |
ICRA | 2 |