Abdullah Alsalemi

dblp:213/8945 · DBLP profile ↗
← Back
4ranked-venue papers in the field
0as first author
4since 2021 · last 2022
0000-0001-7574-4766ORCID · verified

Domains — venue-derived; a paper can count in several

Other / Interdisciplinary · 4
YearPublicationVenuePosition
2022 Recent trends of smart nonintrusive load monitoring in buildings: A review, open challenges, and future directions
abstract
Smart nonintrusive load monitoring (NILM) represents a cost-efficient technology for observing power usage in buildings. It tackles several challenges in transitioning into a more effective, sustainable, and digital energy efficiency environment. This paper presents a comprehensive review of recent trends in the NILM field, in which we propose a multiperspective classification of existing smart NILM techniques. More attention is devoted to describing the contributions of deep learning, feature extraction, computing platforms, and application scenarios for NILM development. Accordingly, NILM technical aspects are first investigated, including data collection devices and public data sets. Next, event-based and non-event-based NILM algorithms are overviewed. Furthermore, potential limitations of existing solutions are identified, highlighting their technical challenges, especially those related to security and privacy preservation, data scarcity, results reproduction, and implementation and business difficulties. Lastly, future directions are explored to overcome the identified limitations.
Yassine Himeur, Abdullah Alsalemi, Faycal Bensaali, Abbes Amira, Ayman Al-Kababji
Int. J. Intell. Syst.2
2021 An intelligent nonintrusive load monitoring scheme based on 2D phase encoding of power signals
abstract
Nonintrusive load monitoring (NILM) is the de facto technique for extracting device-level power consumption fingerprints at (almost) no cost from only aggregated mains readings. Specifically, there is no need to install an individual meter for each appliance. However, a robust NILM system should incorporate a precise appliance identification module that can effectively discriminate between various devices. In this context, this paper proposes a powerful method to extract accurate power fingerprints for electrical appliance identification. Rather than relying solely on time-domain (TD) analysis, this framework abstracts the phase encoding of the TD description of power signals using a two-dimensional (2D) representation. This allows mapping power trajectories to a novel 2D binary representation space, and then performing a histogramming process after converting binary codes to new decimal representations. This yields the final histogram of 2D phase encoding of power signals, namely, 2D-PEP. An empirical performance evaluation conducted with three realistic power consumption databases collected at distinct resolutions indicates that the proposed 2D-PEP descriptor achieves outperformance for appliance identification in comparison with other recent techniques. Accordingly, high identification accuracies are attained on the GREEND, UK-DALE, and WHITED data sets, where 99.54%, 98.78%, and 100% rates have been achieved, respectively, using the proposed 2D-PEP descriptor.
Yassine Himeur, Abdullah Alsalemi, Faycal Bensaali, Abbes Amira
Int. J. Intell. Syst.2
2021 Smart power consumption abnormality detection in buildings using micromoments and improved K-nearest neighbors
abstract
Anomaly detection in energy consumption is a crucial step towards developing efficient energy saving systems, diminishing overall energy expenditure and reducing carbon emissions. Therefore, implementing powerful techniques to identify anomalous consumption in buildings and providing this information to end-users and managers is of significant importance. Accordingly, two novel schemes are proposed in this paper; the first one is an unsupervised abnormality detection based on one-class support vector machine, namely UAD-OCSVM, in which abnormalities are extracted without the need of annotated data; the second is a supervised abnormality detection based on micromoments (SAD-M2), which is implemented in the following steps: (i) normal and abnormal power consumptions are defined and assigned; (ii) a rule-based algorithm is introduced to extract the micromoments representing the intent-rich moments, in which the end-users make decisions to consume energy; and (iii) an improved K-nearest neighbors model is introduced to automatically classify consumption footprints as normal or abnormal. Empirical evaluation conducted in this framework under three different data sets demonstrates that SAD-M2 achieves both a highest abnormality detection performance and real-time processing capability with considerably lower computational cost in comparison with other machine learning methods. For instance, up to 99.71% accuracy and 99.77% F1 score have been achieved using a real-world data set collected at the Qatar University energy lab.
Yassine Himeur, Abdullah Alsalemi, Faycal Bensaali, Abbes Amira
Int. J. Intell. Syst.2
2021 The emergence of explainability of intelligent systems: Delivering explainable and personalized recommendations for energy efficiency
abstract
The recent advances in artificial intelligence namely in machine learning and deep learning, have boosted the performance of intelligent systems in several ways. This gave rise to human expectations, but also created the need for a deeper understanding of how intelligent systems think and decide. The concept of explainability appeared, in the extent of explaining the internal system mechanics in human terms. Recommendation systems are intelligent systems that support human decision making, and as such, they have to be explainable to increase user trust and improve the acceptance of recommendations. In this study, we focus on a context-aware recommendation system for energy efficiency and develop a mechanism for explainable and persuasive recommendations, which are personalized to user preferences and habits. The persuasive facts either emphasize on the economical saving prospects (Econ) or on a positive ecological impact (Eco) and explanations provide the reason for recommending an energy saving action. Based on a study conducted using a Telegram bot, different scenarios have been validated with actual data and human feedback. Current results show a total increase of 19% on the recommendation acceptance ratio when both economical and ecological persuasive facts are employed. This revolutionary approach on recommendation systems, demonstrates how intelligent recommendations can effectively encourage energy saving behavior.
Christos Sardianos, Iraklis Varlamis, Christos Chronis, George Dimitrakopoulos 0001, Abdullah Alsalemi, Yassine Himeur, Faycal Bensaali, Abbes Amira
Int. J. Intell. Syst.5