Demo Data from SIGIR 2026 / reviewers in the wild / expert
Felix Beyeler
dblp:00/6631
· DBLP profile ↗
6ranked-venue papers
3as first author
0since 2021 · last 2011
—ORCID · none
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 6 · 3 first-authorSystems, architecture and hardware · 6 · 3 first-author
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Artificial intelligence
3 papers |
Robot manipulation · 78% Motion planning and robot control · 22% | |
| Computer architecture, parallel and distributed computing, and storage systems
2 papers |
Integrated circuit design · 100% |
Topics — the 6 heaviest of 6, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Integrated circuit design
microelectromechanical systems |
0.2 | 2 | 2010 | Three-axis micro-force sensor with tunable force range and sub-micronewton measurement uncertainty · ICRA 2010 Design and calibration of a microfabricated 6-axis force-torque sensor for microrobotic applications · ICRA 2009 |
Robotics › Motion planning and robot control › robot control › adaptive control
adaptive backstepping control |
0.1 | 1 | 2011 | Adaptive backstepping and MEMS force sensor for an MRI-guided microrobot in the vasculature · ICRA 2011 |
Robotics › Robot manipulation › micro/nano robotics
microrobot control |
0.1 | 1 | 2011 | Adaptive backstepping and MEMS force sensor for an MRI-guided microrobot in the vasculature · ICRA 2011 |
Robotics › Robot manipulation › force sensing
micro-force sensing |
0.1 | 1 | 2010 | Three-axis micro-force sensor with tunable force range and sub-micronewton measurement uncertainty · ICRA 2010 |
Robotics › Robot manipulation
micro/nano manipulation |
0.1 | 1 | 2010 | Three-axis micro-force sensor with tunable force range and sub-micronewton measurement uncertainty · ICRA 2010 |
Robotics › Robot manipulation › tactile sensing
force/tactile sensing |
0.1 | 1 | 2009 | Design and calibration of a microfabricated 6-axis force-torque sensor for microrobotic applications · ICRA 2009 |
Methods — techniques the papers use, named apart from their topics
capacitive sensing · 0.4microfabrication · 0.2sensor calibration · 0.2high-gain observer · 0.1adaptive backstepping · 0.1MEMS force sensor · 0.1
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2011 | Adaptive backstepping and MEMS force sensor for an MRI-guided microrobot in the vasculatureabstract-A microrobot consisting of a polymer binded aggregate of ferromagnetic particles is controlled using a Magnetic Resonance Imaging (MRI) device in order to achieve targeted therapy. The primary contribution of this paper is the design of an adaptive backstepping controller coupled with a high gain observer based on a nonlinear model of a microrobot in a blood vessel. This work is motivated by the difficulty in accurately determining many biological parameters, which can result in parametric uncertainties to which model-based approaches are highly sensitive. We show that the most sensitive parameter, magnetization of the microrobot, can be measured using a Micro-Electro-Mechanical Systems (MEMS) force sensor, while the second one, the dielectric constant of blood, can be estimated on line. The efficacy of this approach is illustrated by simulation results. Laurent Arcese, Matthieu Fruchard, Felix Beyeler, Antoine Ferreira, Bradley J. Nelson |
ICRA | 3 |
| 2011 | The Cellular Force Microscope (CFM): A microrobotic system for quantitating the growth mechanics of living, growing plant cells in situabstractAs the field of biology becomes a more quantitative and predictive natural science, an increasing need for investigation and quantification of the mechanics of growth at individual cellular levels arises. This paper describes a microrobotic force-feedback based system and its application to the mechanical characterization of living, growing plant cells. The Cellular Force Microscope (CFM) is capable of performing the automated mechanical characterization of living plant cells in situ as these cells proliferate and grow. The microrobotic measurement system employs a single-axis capacitive MEMS microforce sensor capable of resolving forces down to 20 nN (1¿, at 10Hz). A multi-axis positioning system with 5 nm resolution position feedback is integrated into a complete system with a high-resolution optical microscope and a custom user interface for guiding an automated force-based measurement process. The CFM has been applied to characterize the mechanical properties of 20¿m wide Lilium pollen tubes while they grow at a rate of about 10 ¿m/min in growth medium. For the mechanical characterization of pollen tubes, loads up to 400 nN are applied that cause indentations up to 300 nm. The force-deformation data acquired show an increase in the observed stiffness from the tip to the apex demonstrating that CFM is a promising tool for better understanding the changing mechanics of living plant cell growth. Dimitrios Felekis, Simon Muntwyler, Felix Beyeler, Bradley J. Nelson |
IROS | 3 |
| 2010 | Three-axis micro-force sensor with tunable force range and sub-micronewton measurement uncertaintyabstractThis paper presents the design, fabrication and characterization of the first microfabricated three-axis tunable force sensor with sub-micronewton measurement uncertainty. The sensing range can be electrically tuned from +/-20 μN to +/-200 μN while taking measurements, ensuring optimal sensor characteristics for a large variety of applications. Since the sensor has been pre-calibrated for the entire tuning range the exact sensor gain and its uncertainty is known. Real-time, three degree of freedom force feedback makes this sensor a valuable tool for micromanipulation. Simon Muntwyler, Felix Beyeler, Bradley J. Nelson |
ICRA | 2 |
| 2009 | Design and calibration of a microfabricated 6-axis force-torque sensor for microrobotic applicationsabstractThis work describes the design of a capacitive multi-axis force-torque sensor for the monitoring of forces in the sub-milli-Newton and sub-micro-Newtonmeter range. This force range makes it a valuable tool for microrobotic applications. The sensor is experimentally investigated and calibrated. This is the first microfabricated 6-axis force-torque sensor that has been successfully developed. Felix Beyeler, Simon Muntwyler, Bradley J. Nelson |
ICRA | 1 |
| 2007 | A multi-axis MEMS force-torque sensor for measuring the load on a microrobot actuated by magnetic fieldsabstractThis paper presents the design of a multi-axis micro force-torque sensor. The sensor is able to measure forces along two axes and a torque perpendicular to these forces. The load is measured by capacitive comb drives which provide a high sensitivity. The microfabrication process, the sensor readout electronics as well as the calibration procedure are presented. The sensor was used to measure the force and torque on a magnetically actuated microrobot. This microrobot is assembled from microfabricated nickel parts for directed drug delivery inside the human body. Precise knowledge load on the microrobot is required for accurate positioning and control of the robot. The three-axis micro sensor is used to simultaneously measure the forces and torques acting on the microrobot in a magnetic field and thus provides valuable data for magnetic control methods of microrobots. Felix Beyeler, Simon Muntwyler, Zoltán Nagy 0002, Mathias Franz Karl Moser, Bradley J. Nelson |
IROS | 1 |
| 2006 | Design of a Micro-Gripper and an Ultrasonic Manipulator for Handling Micron Sized ObjectsabstractThis work reports on a system consisting of a MEMS (microelectromechanical system) gripper and an ultrasonic manipulator. The gripper is electrostatically actuated and includes an integrated force sensor measuring the gripping force. The device is monolithically fabricated using a silicon-on-insulator (SOI) fabrication process. The resolution of the force sensor is in the sub-micronewton range and, therefore, provides feedback of the forces that dominate the micromanipulation processes. A MEMS ultrasonic device is described which aligns small objects such as biological cells prior to manipulation with the gripper. The concept is demonstrated with polymer spheres, glass spheres and Hela cancer cells, thus providing a useful tool in micro-robotics and biological research Felix Beyeler, Dominik J. Bell, Bradley J. Nelson, Yu Sun 0001, Adrian Neild, S. Oberti, Jurg Dual |
IROS | 1 |