Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Erick Nieves-Rivera

dblp:00/7748 · also Erick Nieves · DBLP profile ↗
← Back
3ranked-venue papers
1as first author
0since 2021 · last 2014
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 3 · 1 first-authorSystems, architecture and hardware · 3 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
2 papers
Motion planning and robot control · 94% Robot manipulation · 6%

Topics — the 6 heaviest of 6, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Motion planning and robot control › motion planning › manipulation planning
mobile manipulator planning
0.212014
Coordination of a nonholonomic mobile platform and an on-board manipulator · ICRA 2014
Robotics › Motion planning and robot control
motion planning
0.212014
Coordination of a nonholonomic mobile platform and an on-board manipulator · ICRA 2014
Robotics › Motion planning and robot control
robot calibration
0.212014
Robot control system for multi-position alignment used to automate an industrial robot calibration approach · ICRA 2014
Robotics › Motion planning and robot control
robot control
0.212014
Coordination of a nonholonomic mobile platform and an on-board manipulator · ICRA 2014
Robotics › Motion planning and robot control › robot control
industrial robot control
0.112014
Robot control system for multi-position alignment used to automate an industrial robot calibration approach · ICRA 2014
Robotics › Robot manipulation › mobile manipulation
mobile manipulator coordination
0.112014
Coordination of a nonholonomic mobile platform and an on-board manipulator · ICRA 2014

Methods — techniques the papers use, named apart from their topics

simulation · 0.2planning and control · 0.2perceptive reference frame · 0.2control system design · 0.2
YearPublicationVenuePosition
2014 Coordination of a nonholonomic mobile platform and an on-board manipulator
abstract
Mobile manipulators provide more advantages and flexibility in a wide range of applications than standard manipulators by introducing mobility. However, adding mobile platforms to standard manipulators, especially nonholonomic mobile platforms, introduces new challenges to the system modeling and control. Most existing methods for mobile manipulators do not consider the performance difference between the mobile platform and the manipulator and therefore cannot handle the uncertain and unexpected events happened in both the mobile platform and the manipulator. This paper introduces a planning and control method in a perceptive reference frame for a nonholonomic mobile manipulator to efficiently handle uncertain and unexpected events. The experimental results on a nonholonomic mobile manipulator demonstrate the effectiveness and advantages of the designed method.
Yunyi Jia, Ning Xi 0001, Erick Nieves-Rivera
ICRA3
2014 Robot control system for multi-position alignment used to automate an industrial robot calibration approach
abstract
Robot calibration is widely used in the manufacture industry to enhance and achieve a higher level of accuracy on industrial robot manipulators. Currently, there are many reliable calibration systems able to perform the calibration task. Those systems, however, are far from being a user friendly calibration tool; they are time consuming, very expensive, and usually requires a lot of human interaction. Therefore, we proposed a new calibration system able to overcome those problems with promising results. However, to take the system to the next level, and create an automated calibration process, we need to create a control system capable of guiding the robot's tool center point to a multi-position alignment. Throughout this paper the control approach needed to achieve automation of the entire system is presented and discussed. Simulations and experimental results demonstrated the feasibility of the overall calibration system including hardware, software and control algorithms.
Erick Nieves-Rivera, Ning Xi 0001
ICRA1
2009 Development and sensitivity analysis of a portable calibration system for joint offset of industrial robot
abstract
This paper describes our updated system for industrial robot joint offset calibration. The system consists of an IRB1600 industrial robot, a laser tool attached to the robot's end-effector, a portable position-sensitive device (PPD), and a PC based controller. By aiming the laser spot to the center of position-sensitive-detector (PSD) on the PPD with different robot configurations, the developed system ideally implements our proposed calibration method called the virtual line-based single-point constraint approach. However, unlike our previous approach, the calibration method is extended to identify the offset parameters with an uncalibrated laser tool. The position errors of the PPD and the sensitivities of error in the PSD plane to the variation of joint angles are analyzed. Two different robot configuration patterns are compared by implementing the calibration method. Both simulation and real experimental results are consistent with the mathematical analysis. Experimental results with small (10−3−10−2) mean and standard deviation of parameters error verify the effectiveness of both the sensitivity analysis and the developed system.
Ning Xi 0001, Erick Nieves-Rivera, Yunyi Jia, Bingtuan Gao
IROS4