Demo Data from SIGIR 2026 / reviewers in the wild / expert
Giovanni Stellin
dblp:11/3873
· DBLP profile ↗
3ranked-venue papers
0as first author
0since 2021 · last 2006
0000-0002-1903-2542ORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 3Systems, architecture and hardware · 3
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Artificial intelligence
1 paper |
Robot manipulation · 91% Motion planning and robot control · 9% |
Topics — the 4 heaviest of 4, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Robotics › Robot manipulation
grasping |
0.1 | 1 | 2006 | Closed-loop Controller for a Bio-inspired Multi-fingered Underactuated Prosthesis · ICRA 2006 |
Robotics › Robot manipulation › robotic hand
prosthetic hand control |
0.1 | 1 | 2006 | Closed-loop Controller for a Bio-inspired Multi-fingered Underactuated Prosthesis · ICRA 2006 |
Robotics › Robot manipulation › robotic hand
underactuated tendon-driven hand |
0.1 | 1 | 2006 | Closed-loop Controller for a Bio-inspired Multi-fingered Underactuated Prosthesis · ICRA 2006 |
Robotics › Motion planning and robot control › robot control › feedback control
PID control |
0.0 | 1 | 2006 | Closed-loop Controller for a Bio-inspired Multi-fingered Underactuated Prosthesis · ICRA 2006 |
Methods — techniques the papers use, named apart from their topics
force closure computation · 0.1PID position control · 0.1
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2006 | Closed-loop Controller for a Bio-inspired Multi-fingered Underactuated ProsthesisabstractThe paper presents a controller for a multi-fingered underactuated prosthetic hand based on tendon transmission. The control architecture is implemented in two subsequent and different phases. The first one is the pre-shaping of the hand, based on the grasp type is implemented by stand-alone motion controllers using PID position control algorithms. The desired force closure value is calculated according to the pre-shape measured tendons tension and to the grasping force. In the second phase, the involved fingers rapidly close around the object to perform a balanced distribution of the forces within the hand, as it happens in the human hand. The controller is thus able to perform successfully many stable grasps. An overview of the hardware architecture and the results in terms of grasping capabilities based on Cutkosky grasp taxonomy are also presented Christian Cipriani, Franco Zaccone, Giovanni Stellin, Lucia Beccai, Giovanni Cappiello, Maria Chiara Carrozza, Paolo Dario |
ICRA | 3 |
| 2005 | A Cosmetic Prosthetic Hand with Tendon Driven Under-Actuated Mechanism and Compliant Joints: Ongoing Research and Preliminary ResultsabstractThis paper presents recent results aimed at developing a functional prosthetic hand characterized by an EMG-control and by a simple and low cost fabrication technology. In order to overcome some limitations of current prosthetic hands mainly related to the poor functionality and controllability, the prosthetic hand has been designed following a biomechatronic approach based on biologically-inspired design solutions. The core of the project described in this paper is the fabrication of a compliant under-actuated prosthetic hand: the structure of the hand (both palm and fingers) is moulded as a soft polymeric single part with compliant joints and embedded tendon driven underactuated mechanism for providing adaptive grasp. In order to make user trials, the hand is equipped with simple but functional EMG-based control of the single motor incorporated in the hand, and is integrated with a prosthesis socket. The paper presents the biomechatronics design, the fabrication process, the integration of the prosthetic device and first experimental results. Maria Chiara Carrozza, Giovanni Cappiello, Giovanni Stellin, Franco Zaccone, Fabrizio Vecchi, Silvestro Micera, Paolo Dario |
ICRA | 3 |
| 2005 | On the development of a novel adaptive prosthetic hand with compliant joints: experimental platform and EMG controlabstractIn this paper, some recent results about the experimental trials we are performing on a functional prosthetic hand characterized by an EMG-control and by a simple and low cost fabrication technology are shown. The innovation described in this paper is the fabrication of a compliant under-actuated prosthetic hand. The structure of the hand (both palm and fingers) is moulded as a soft polymeric single part with compliant joints and embedded tendon driven under-actuated mechanism for providing adaptive grasp. The prosthetic hand has been designed following a biomechatronic approach based on biologically-inspired design solutions. We describe the second release of this prosthesis. The evaluating tests are related to the maximum force exerted during grasping and to the fatigue problems occurring with cables and joint. Maria Chiara Carrozza, Giovanni Cappiello, Giovanni Stellin, Franco Zaccone, Fabrizio Vecchi, Silvestro Micera, Paolo Dario |
IROS | 3 |