Demo Data from SIGIR 2026 / reviewers in the wild / expert
Brian Edward Lawson
dblp:116/3159
· DBLP profile ↗
5ranked-venue papers
2as first author
0since 2021 · last 2019
—ORCID · conflict
Domains — the database's venue-derived domains; a paper can count in several
Applied, interdisciplinary, general and emerging computing · 3 · 1 first-authorArtificial intelligence and machine learning · 2 · 1 first-authorSystems, architecture and hardware · 2 · 1 first-author
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Artificial intelligence
2 papers |
Robot manipulation · 41% Motion planning and robot control · 31% Legged, aerial and field robots · 28% |
Topics — the 6 heaviest of 6, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Robotics › Robot manipulation › wearable robotics › prosthetic device
prosthesis control |
0.2 | 1 | 2013 | Evaluation of a coordinated control system for a pair of powered transfemoral prostheses · ICRA 2013 |
Robotics › Motion planning and robot control
robot control |
0.2 | 1 | 2013 | Evaluation of a coordinated control system for a pair of powered transfemoral prostheses · ICRA 2013 |
Robotics › Legged, aerial and field robots
legged robots |
0.0 | 1 | 2013 | Evaluation of a coordinated control system for a pair of powered transfemoral prostheses · ICRA 2013 |
Robotics › Legged, aerial and field robots › legged robots
legged robot locomotion |
0.0 | 1 | 2013 | Preliminary evaluation of a walking controller for a powered ankle prosthesis · ICRA 2013 |
Robotics › Robot manipulation › medical robotics
powered prosthesis |
0.0 | 1 | 2013 | Evaluation of a coordinated control system for a pair of powered transfemoral prostheses · ICRA 2013 |
Robotics › Legged, aerial and field robots
walking control |
0.0 | 1 | 2013 | Preliminary evaluation of a walking controller for a powered ankle prosthesis · ICRA 2013 |
Methods — techniques the papers use, named apart from their topics
motion capture · 0.2level walking controller · 0.2
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2019 | A Velocity-Field-Based Controller for Assisting Leg Movement During Walking With a Bilateral Hip and Knee Lower Limb ExoskeletonabstractThis paper presents a control approach for an overground lower limb exoskeleton that is intended to provide guidance and assistance to poorly ambulatory individuals during walking without unduly interfering with their ability to maintain balance. The control approach achieves these objectives by emulating a viscous flow field acting on the lower limb joints. The extent to which the control approach achieves the objectives was assessed in experiments, conducted on five healthy subjects, comparing guidance and disturbance characteristics of the velocity-based controller to a potential-field-based controller. Results show that the flow controller provides a combination of lower guidance error and lower disturbance to the user, relative to the potential-field-based controller. The paper also discusses various potentially beneficial characteristics of the flow controller, such as first-order homogeneous behavior, implicitly combined guidance and assistance behaviors, and improved directionality in error correction relative to a potential-field-based controller. Andres Martinez 0002, Brian Edward Lawson, Christina M. Durrough, Michael Goldfarb |
IEEE Trans. Robotics | 2 |
| 2018 | A Controller for Guiding Leg Movement During Overground Walking With a Lower Limb ExoskeletonabstractThis paper describes a lower limb exoskeleton control approach that facilitates a desired movement coordination between the hip and knee joints during the swing phase of gait. An important feature of the proposed controller is that it provides movement guidance while allowing a user to control step time and step length. Specifically, control of step time is enabled by the use of time-invariant movement constraints, while control of step length is enabled by a real-time path-planning feature. As such, the controller provides movement coordination, but still enables a user to retain the step-to-step variability required to maintain balance during walking. The controller was implemented on a lower limb exoskeleton and tested on five healthy subjects. The subjects walked overground in the exoskeleton without a stability aid under two conditions: with the proposed coordination controller (i.e., with sagittal plane movement constraints) and with no control implemented (i.e., without sagittal plane movement constraints). Data from these assessments indicate that the controller provided substantial movement coordination while still allowing subjects substantive control of step time and length across a range of walking speeds. Andres Martinez 0002, Brian Edward Lawson, Michael Goldfarb |
IEEE Trans. Robotics | 2 |
| 2017 | A Robotic Lower Limb Prosthesis for Efficient BicyclingabstractA controller for a powered transfemoral prosthesis is presented, which can coordinate power delivery at the knee with the motion of the crankshaft on a bicycle. The controller continuously estimates the lengths of a four-bar linkage model through the application of a recursive least squares algorithm. The link lengths are used to estimate the angle of the bicycle crankshaft. With this measure, the delivery of knee torque is coordinated with the motion of the user. The controller is implemented on a prosthesis prototype and assessed on a transfemoral amputee subject ( N = 1). The subject exhibited a bilateral work asymmetry of 83.5% when cycling with his daily use prosthesis in a free-swing mode. When 60-N·m peak assistance was provided by the powered prosthesis, the bilateral work asymmetry was reduced to 11.4%. The subject's metabolic energy rate was measured for speed and power-matched cycling while the powered prosthesis provided zero assistance (i.e., turned off and providing its back-drive resistance) or 30-N·m peak assistance. Subject's metabolic energy rate decreased by 16.5% when receiving powered assistance relative to the zero-assistance condition. Brian Edward Lawson, Elissa Ledoux, Michael Goldfarb |
IEEE Trans. Robotics | 1 |
| 2013 | Evaluation of a coordinated control system for a pair of powered transfemoral prosthesesabstractThe authors present a control system for a pair of powered prostheses that leverages communication between the devices in order to enhance awareness and improve stability for the user. The control system is implemented on a pair of powered knee and ankle prostheses previously developed by the authors and tested on a healthy subject using able body adapters. The healthy subject also walked on a pair of passive prostheses, with both cases being monitored through motion capture. The kinematic data from the powered system closely match those seen in healthy subjects and show a marked improvement over the passive devices. Brian Edward Lawson, Amanda Huff Shultz, Michael Goldfarb |
ICRA | 1 |
| 2013 | Preliminary evaluation of a walking controller for a powered ankle prosthesisabstractThis paper describes a level walking controller for a powered ankle prosthesis. The controller was implemented on a powered prosthesis prototype and evaluated on a healthy subject by means of able-bodied adapters on a treadmill walking at 1.2 m/s (4.3 km/h). The ankle joint kinematics provided by the powered prosthesis were compared to that provided by a passive (dynamic elastic response) prosthesis, and both compared to the typical kinematics of healthy gait. The comparison indicates the powered prosthesis better reproduces the kinematics of healthy gait, relative to the passive prosthesis. The torque, energy transfer, and power provided by the powered prosthesis were additionally compared to that of a typical healthy subject. Amanda Huff Shultz, Jason E. Mitchell, Don Truex, Brian Edward Lawson, Michael Goldfarb |
ICRA | 4 |