Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Bernhard Fuerst

dblp:117/1844 · DBLP profile ↗
← Back
14ranked-venue papers
6as first author
0since 2021 · last 2017
0000-0001-7439-8312ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 10 · 6 first-authorGraphics, computer vision, multimedia, augmented reality and games · 7 · 3 first-authorArtificial intelligence and machine learning · 2Systems, architecture and hardware · 2Human-computer interaction and ubiquitous computing · 2

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
2 papers
Motion planning and robot control · 100%
Computer graphics and multimedia
2 papers
Virtual and augmented reality · 71% Computational photography and imaging · 29%
Interdisciplinary, comprehensive, and emerging computing
2 papers
Medical and health informatics · 100%
Human-computer interaction and pervasive computing
2 papers
Immersive interaction · 82% Haptics and multimodal interaction · 18%

Topics — the 11 heaviest of 12, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Immersive interaction
augmented reality
0.312017
Exploring non-reversing magic mirrors for screen-based augmented reality systems · VR 2017
Robotics › Motion planning and robot control
robot control
0.212016
Toward real-time 3D ultrasound registration-based visual servoing for interventional navigation · ICRA 2016
Robotics › Motion planning and robot control
trajectory planning
0.212016
Robotic ultrasound trajectory planning for volume of interest coverage · ICRA 2016
Robotics › Motion planning and robot control › robot control › sensor-based control
visual servoing
0.212016
Toward real-time 3D ultrasound registration-based visual servoing for interventional navigation · ICRA 2016
Medical and health informatics
image-guided intervention
0.212016
Toward real-time 3D ultrasound registration-based visual servoing for interventional navigation · ICRA 2016
Computational photography and imaging
3d vision
0.212015
Auditory and Visio-Temporal Distance Coding for 3-Dimensional Perception in Medical Augmented Reality · ISMAR 2015
Virtual and augmented reality
augmented reality
0.212015
Auditory and Visio-Temporal Distance Coding for 3-Dimensional Perception in Medical Augmented Reality · ISMAR 2015
Virtual and augmented reality › augmented reality
medical augmented reality
0.212015
Auditory and Visio-Temporal Distance Coding for 3-Dimensional Perception in Medical Augmented Reality · ISMAR 2015
Medical and health informatics › computer-assisted surgery
needle insertion
0.112016
Toward real-time 3D ultrasound registration-based visual servoing for interventional navigation · ICRA 2016
Medical and health informatics › medical robotics
robotic ultrasound acquisition
0.112016
Robotic ultrasound trajectory planning for volume of interest coverage · ICRA 2016
Haptics and multimodal interaction
auditory feedback
0.112015
Auditory and Visio-Temporal Distance Coding for 3-Dimensional Perception in Medical Augmented Reality · ISMAR 2015

Methods — techniques the papers use, named apart from their topics

comparative study · 0.6spline trajectory generation · 0.5impedance control · 0.5GPU-based image processing · 0.53d ultrasound registration · 0.5temporal distance coding · 0.4
YearPublicationVenuePosition
2017 Exploring non-reversing magic mirrors for screen-based augmented reality systems
abstract
Screen-based Augmented Reality (AR) systems can be built as a window into the real world as often done in mobile AR applications or using the Magic Mirror metaphor, where users can see themselves with augmented graphics on a large display. The term Magic Mirror implies that the display shows the users enantiomorph, i.e. the mirror image, such that the system mimics a real-world physical mirror. However, the question arises whether one should design a traditional mirror, or instead display the true mirror image by means of a non-reversing mirror? We discuss the perceptual differences between these two mirror visualization concepts and present a first comparative study in the context of Magic Mirror anatomy teaching.
Felix Bork, Roghayeh Barmaki, Ulrich Eck, Pascal Fallavollita, Bernhard Fuerst, Nassir Navab
VR5
2017 Towards MRI-Based Autonomous Robotic US Acquisitions: A First Feasibility Study
abstract
Robotic ultrasound has the potential to assist and guide physicians during interventions. In this work, we present a set of methods and a workflow to enable autonomous MRI-guided ultrasound acquisitions. Our approach uses a structured-light 3D scanner for patient-to-robot and image-to-patient calibration, which in turn is used to plan 3D ultrasound trajectories. These MRI-based trajectories are followed autonomously by the robot and are further refined online using automatic MRI/US registration. Despite the low spatial resolution of structured light scanners, the initial planned acquisition path can be followed with an accuracy of 2.46 ± 0.96 mm. This leads to a good initialization of the MRI/US registration: the 3D-scan-based alignment for planning and acquisition shows an accuracy (distance between planned ultrasound and MRI) of 4.47 mm, and 0.97 mm after an online-update of the calibration based on a closed loop registration.
Christoph Hennersperger, Bernhard Fuerst, Salvatore Virga, Oliver Zettinig, Benjamin Frisch, Thomas Neff, Nassir Navab
IEEE Trans. Medical Imaging2
2016 Robotic ultrasound trajectory planning for volume of interest coverage
abstract
Medical robotic ultrasound offers potential to assist interventions, ease long-term monitoring and reduce operator dependency. Various techniques for remote control of ultrasound probes through telemanipulation systems have been presented in the past, however not exploiting the potential of fully autonomous acquisitions directly performed by robotic systems. In this paper, a trajectory planning algorithm for automatic robotic ultrasound acquisition under expert supervision is introduced. The objective is to compute a suitable path for covering a volume of interest selected in diagnostic images, for example by prior segmentation. A 3D patient surface point cloud is acquired using a depth camera, which is the sole prerequisite besides the volume delineation. An easily parameterizable path function generates single or multiple parallel scan trajectories capable of dealing with large target volumes. A spline is generated through the preliminary path points and is transferred to a lightweight robot to perform the ultrasound scan using an impedance control mode. The proposed approach is validated via simulation as well as on phantoms and on animal viscera.
Christoph Graumann, Bernhard Fuerst, Christoph Hennersperger, Felix Bork, Nassir Navab
ICRA2
2016 Toward real-time 3D ultrasound registration-based visual servoing for interventional navigation
abstract
While intraoperative imaging is commonly used to guide surgical interventions, automatic robotic support for image-guided navigation has not yet been established in clinical routine. In this paper, we propose a novel visual servoing framework that combines, for the first time, full image-based 3D ultrasound registration with a real-time servo-control scheme. Paired with multi-modal fusion to a pre-interventional plan such as an annotated needle insertion path, it thus allows tracking a target anatomy, continuously updating the plan as the target moves, and keeping a needle guide aligned for accurate manual insertion. The presented system includes a motorized 3D ultrasound transducer mounted on a force-controlled robot and a GPU-based image processing toolkit. The tracking accuracy of our framework is validated on a geometric agar/gelatin phantom using a second robot, achieving positioning errors of on average 0.42-0.44 mm. With compounding and registration runtimes of up to total around 550 ms, real-time performance comes into reach. We also present initial results on a spine phantom, demonstrating the feasibility of our system for lumbar spine injections.
Oliver Zettinig, Bernhard Fuerst, Risto Kojcev, Mehrdad Salehi, Wolfgang Wein, Julia Rackerseder, Edoardo Sinibaldi, Benjamin Frisch, Nassir Navab
ICRA2
2016 Bioelectric Navigation: A New Paradigm for Intravascular Device Guidance
Bernhard Fuerst, Erin E. Sutton, Reza Ghotbi, Noah J. Cowan, Nassir Navab
MICCAI (1)1
2016 Personalized, relevance-based Multimodal Robotic Imaging and augmented reality for Computer Assisted Interventions
Nassir Navab, Christoph Hennersperger, Benjamin Frisch, Bernhard Fuerst
Medical Image Anal.4
2016 First Robotic SPECT for Minimally Invasive Sentinel Lymph Node Mapping
abstract
In this paper we present the usage of a drop-in gamma probe for intra-operative Single-Photon Emission Computed Tomography (SPECT) imaging in the scope of minimally invasive robot-assisted interventions. The probe is designed to be inserted and reside inside the abdominal cavity during the intervention. It is grasped during the procedure using a robotic laparoscopic gripper enabling full six degrees of freedom handling by the surgeon. We demonstrate the first deployment of the tracked probe for intra-operative in-patient robotic SPECT enabling augmented-reality image guidance. The hybrid mechanical- and image-based in-patient probe tracking is shown to have an accuracy of 0.2 mm. The overall system performance is evaluated and tested with a phantom for gynecological sentinel lymph node interventions and compared to ground-truth data yielding a mean reconstruction accuracy of 0.67 mm.
Bernhard Fuerst, Julian Sprung, Francisco Pinto, Benjamin Frisch, Thomas Wendler 0001, Hervé Simon, Laurent Mengus, Nynke S. van den Berg, Henk G. van der Poel, Fijs W. B. van Leeuwen, Nassir Navab
IEEE Trans. Medical Imaging1
2015 Auditory and Visio-Temporal Distance Coding for 3-Dimensional Perception in Medical Augmented Reality
abstract
Image-guided medical interventions more frequently rely on Augmented Reality (AR) visualization to enable surgical navigation. Current systems use 2-D monitors to present the view from external cameras, which does not provide an ideal perception of the 3-D position of the region of interest. Despite this problem, most research targets the direct overlay of diagnostic imaging data, and only few studies attempt to improve the perception of occluded structures in external camera views. The focus of this paper lies on improving the 3-D perception of an augmented external camera view by combining both auditory and visual stimuli in a dynamic multi-sensory AR environment for medical applications. Our approach is based on Temporal Distance Coding (TDC) and an active surgical tool to interact with occluded virtual objects of interest in the scene in order to gain an improved perception of their 3-D location. Users performed a simulated needle biopsy by targeting virtual lesions rendered inside a patient phantom. Experimental results demonstrate that our TDC-based visualization technique significantly improves the localization accuracy, while the addition of auditory feedback results in increased intuitiveness and faster completion of the task.
Felix Bork, Bernhard Fuerst, Anja-Katharina Schneider, Francisco Pinto, Christoph Graumann, Nassir Navab
ISMAR2
2015 Vision-Based Intraoperative Cone-Beam CT Stitching for Non-overlapping Volumes
Bernhard Fuerst, Javad Fotouhi, Nassir Navab
MICCAI (1)1
2015 Radiopositive Tissue Displacement Compensation for SPECT-guided Surgery
Francisco Pinto, Bernhard Fuerst, Benjamin Frisch, Nassir Navab
MICCAI (2)2
2015 Patient-Specific Biomechanical Model for the Prediction of Lung Motion From 4-D CT Images
abstract
This paper presents an approach to predict the deformation of the lungs and surrounding organs during respiration. The framework incorporates a computational model of the respiratory system, which comprises an anatomical model extracted from computed tomography (CT) images at end-expiration (EE), and a biomechanical model of the respiratory physiology, including the material behavior and interactions between organs. A personalization step is performed to automatically estimate patient-specific thoracic pressure, which drives the biomechanical model. The zone-wise pressure values are obtained by using a trust-region optimizer, where the estimated motion is compared to CT images at end-inspiration (EI). A detailed convergence analysis in terms of mesh resolution, time stepping and number of pressure zones on the surface of the thoracic cavity is carried out. The method is then tested on five public datasets. Results show that the model is able to predict the respiratory motion with an average landmark error of 3.40 ±1.0 mm over the entire respiratory cycle. The estimated 3-D lung motion may constitute as an advanced 3-D surrogate for more accurate medical image reconstruction and patient respiratory analysis.
Bernhard Fuerst, Tommaso Mansi, Francois Carnis, Martin Salzle, Jingdan Zhang, Jérôme Declerck, Thomas Böttger, John E. Bayouth, Nassir Navab, Ali Kamen
IEEE Trans. Medical Imaging1
2014 Automatic ultrasound-MRI registration for neurosurgery using the 2D and 3D LC2 Metric
Bernhard Fuerst, Wolfgang Wein, Nassir Navab
Medical Image Anal.1
2013 Global Registration of Ultrasound to MRI Using the LC2 Metric for Enabling Neurosurgical Guidance
Wolfgang Wein, Alexander Ladikos, Bernhard Fuerst, Amit Shah, Kanishka Sharma, Nassir Navab
MICCAI (1)3
2012 A Personalized Biomechanical Model for Respiratory Motion Prediction
Bernhard Fuerst, Tommaso Mansi, Parmeshwar Khurd, Jérôme Declerck, Thomas Böttger, Nassir Navab, John E. Bayouth, Dorin Comaniciu, Ali Kamen
MICCAI (3)1