Cailing Yang

dblp:119/9477 · DBLP profile ↗
← Back
1ranked-venue papers
0as first author
0since 2021 · last 2013
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 1Systems, architecture and hardware · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Human-computer interaction and pervasive computing
1 paper
Haptics and multimodal interaction · 100%
Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%

Topics — the 2 heaviest of 2, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Haptics and multimodal interaction › tactile sensing
haptic sensing
0.212013
A novel design of a wearable device for measuring force and torque in vascular surgery · ICRA 2013
Medical and health informatics › medical simulation
surgical simulation
0.012013
A novel design of a wearable device for measuring force and torque in vascular surgery · ICRA 2013
YearPublicationVenuePosition
2013 A novel design of a wearable device for measuring force and torque in vascular surgery
abstract
In-vivo measurement of force/torque signals between a surgical tool and human vessels during vascular surgery operations could provide a ground-truth data-set for constructing and evaluating haptics-enabled surgical simulation systems. In this paper, we introduce a novel wearable device for measuring such signals. This new design provides much higher measurement accuracy than a previous prototype. Experimental results by using standard weights provide that the relative force and torque error is about 5%. With time-varying load, the new device is compared with an ATI Nano17 force/torque sensor; average relative errors between the force signals is about 16.85%, and average relative errors between the torque signals is about 28.74%. Preliminary manipulation experiments of inserting a catheter into a vascular phantom model illustrated that the device can detect the collision between the catheter and the vascular walls. Subtle force/torque changes caused by changes of movement direction can be detected. Force/torque changes at some critical point (such as the interaction point of vessels) can also be detected.
Dangxiao Wang, Cailing Yang, Jing Xiao 0001, Yongpan Dong
ICRA2