Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Li-Ren Lin

dblp:126/5117 · DBLP profile ↗
← Back
1ranked-venue papers
1as first author
0since 2021 · last 1996
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 1 · 1 first-authorSystems, architecture and hardware · 1 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
1 paper
Robot manipulation · 77% Motion planning and robot control · 23%

Topics — the 4 heaviest of 4, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Robot manipulation › robotic hand
multi-fingered robot hand
0.011996
Mechanism design of a new multifingered robot hand · ICRA 1996
Robotics › Robot manipulation
robotic hand design
0.011996
Mechanism design of a new multifingered robot hand · ICRA 1996
Robotics › Motion planning and robot control › robot kinematics
forward and inverse kinematics
0.011996
Mechanism design of a new multifingered robot hand · ICRA 1996
Robotics › Motion planning and robot control › robot kinematics
kinematic modeling
0.011996
Mechanism design of a new multifingered robot hand · ICRA 1996

Methods — techniques the papers use, named apart from their topics

mechanism design · 0.0kinematic analysis · 0.0
YearPublicationVenuePosition
1996 Mechanism design of a new multifingered robot hand
abstract
A new five-finger robot hand (NTU hand) with seventeen degrees of freedom (DOF) is developed in this paper. In contrast to traditional tendon-driven robot, the NTU hand has an uncoupled configuration such that each finger and joint are all individually driven. While all actuators, mechanical parts and sensors are packed on the hand, the size of NTU hand is almost the same as a human hand. Such compact design makes the hand easily adapt to industrial robot arms and prosthetic applications. According to the mechanical structure of the NTU hand, the direct and inverse kinematics are also developed in this paper.
Li-Ren Lin, Han-Pang Huang
ICRA1