Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Joaquín Otón

dblp:135/5857 · DBLP profile ↗
← Back
3ranked-venue papers
0as first author
0since 2021 · last 2019
0000-0002-2195-4730ORCID · reported

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 2Graphics, computer vision, multimedia, augmented reality and games · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
2 papers
Bioinformatics and computational biology · 100%

Topics — the 3 heaviest of 3, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Bioinformatics and computational biology › structural biology
cryo-electron microscopy
0.522019
Validation of electron microscopy initial models via small angle X-ray scattering curves · Bioinform. 2019
A pattern matching approach to the automatic selection of particles from low-contrast electron micrographs · Bioinform. 2013
Bioinformatics and computational biology › structural biology
small angle x-ray scattering analysis
0.412019
Validation of electron microscopy initial models via small angle X-ray scattering curves · Bioinform. 2019
Bioinformatics and computational biology › bioimage informatics › single-particle analysis
particle picking
0.212013
A pattern matching approach to the automatic selection of particles from low-contrast electron micrographs · Bioinform. 2013

Methods — techniques the papers use, named apart from their topics

pseudo-atomic modeling · 0.4support vector machine · 0.2shape feature extraction · 0.2
YearPublicationVenuePosition
2019 Validation of electron microscopy initial models via small angle X-ray scattering curves
abstract
MOTIVATION: Cryo electron microscopy (EM) is currently one of the main tools to reveal the structural information of biological macromolecules. The re-construction of three-dimensional (3D) maps is typically carried out following an iterative process that requires an initial estimation of the 3D map to be refined in subsequent steps. Therefore, its determination is key in the quality of the final results, and there are cases in which it is still an open issue in single particle analysis (SPA). Small angle X-ray scattering (SAXS) is a well-known technique applied to structural biology. It is useful from small nanostructures up to macromolecular ensembles for its ability to obtain low resolution information of the biological sample measuring its X-ray scattering curve. These curves, together with further analysis, are able to yield information on the sizes, shapes and structures of the analyzed particles. RESULTS: In this paper, we show how the low resolution structural information revealed by SAXS is very useful for the validation of EM initial 3D models in SPA, helping the following refinement process to obtain more accurate 3D structures. For this purpose, we approximate the initial map by pseudo-atoms and predict the SAXS curve expected for this pseudo-atomic structure. The match between the predicted and experimental SAXS curves is considered as a good sign of the correctness of the EM initial map. AVAILABILITY AND IMPLEMENTATION: The algorithm is freely available as part of the Scipion 1.2 software at http://scipion.i2pc.es/.
Amaya Jiménez, Slavica Jonic, Tomás Majtner, Joaquín Otón, Jose Luis Vilas, David Maluenda, Javier Mota, Erney Ramírez-Aportela, Marta Martínez, Yaiza Rancel, Joan Segura, Rubén Sánchez García, Roberto Melero, Laura del Cano, Pablo Conesa, Lars Skjærven, Roberto Marabini, José María Carazo, Carlos Oscar Sánchez Sorzano
Bioinform.4
2014 An image processing approach to the simulation of electron microscopy volumes of atomic structures
abstract
The goal of this paper is to construct accurate three-dimensional models from atomic structures that can be compared to Electron Microscopy volumes. They, in their turn, can be used to solve fitting and docking problems as well as to generate ground-truth models for the development of image processing algorithms. We use Electron Atomic Scattering Factor (EASF) along with a careful filter design to greatly accelerate the current use of these functions and strongly reduce computer memory requirements. We show that our method is 3 orders of magnitude faster than existing implementations of EASFs in Fourier space as well as more accurate than their standard implementations. The algorithm is freely available in the software package Xmipp (http://xmipp.cnb.csic.es) [1].
Carlos Oscar Sánchez Sorzano, Javier Vargas 0001, Joaquín Otón, Vahid Abrishami, José Miguel de la Rosa-Trevín, S. del Riego, A. Fernandez-Alderete, C. Martinez-Rey, Roberto Marabini, José María Carazo
ICIP3
2013 A pattern matching approach to the automatic selection of particles from low-contrast electron micrographs
abstract
MOTIVATION: Structural information of macromolecular complexes provides key insights into the way they carry out their biological functions. Achieving high-resolution structural details with electron microscopy requires the identification of a large number (up to hundreds of thousands) of single particles from electron micrographs, which is a laborious task if it has to be manually done and constitutes a hurdle towards high-throughput. Automatic particle selection in micrographs is far from being settled and new and more robust algorithms are required to reduce the number of false positives and false negatives. RESULTS: In this article, we introduce an automatic particle picker that learns from the user the kind of particles he is interested in. Particle candidates are quickly and robustly classified as particles or non-particles. A number of new discriminative shape-related features as well as some statistical description of the image grey intensities are used to train two support vector machine classifiers. Experimental results demonstrate that the proposed method: (i) has a considerably low computational complexity and (ii) provides results better or comparable with previously reported methods at a fraction of their computing time. AVAILABILITY: The algorithm is fully implemented in the open-source Xmipp package and downloadable from http://xmipp.cnb.csic.es.
Vahid Abrishami, Airen Zaldívar-Peraza, José Miguel de la Rosa-Trevín, Javier Vargas 0001, Joaquín Otón, Roberto Marabini, Yoel Shkolnisky, José María Carazo, Carlos Oscar Sánchez Sorzano
Bioinform.5