Demo Data from SIGIR 2026 / reviewers in the wild / expert
Brendan Quinlivan
dblp:135/8149
· DBLP profile ↗
2ranked-venue papers
0as first author
0since 2021 · last 2014
—ORCID · none
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 2Systems, architecture and hardware · 2
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Human-computer interaction and pervasive computing
2 papers |
Human-robot interaction · 81% Accessibility and assistive technology · 19% |
Topics — the 6 heaviest of 6, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Human-robot interaction › wearable robot
soft exosuit |
0.4 | 2 | 2014 | Multi-joint actuation platform for lower extremity soft exosuits · ICRA 2014 A lightweight soft exosuit for gait assistance · ICRA 2013 |
Human-robot interaction › physical human-robot interaction
admittance control |
0.2 | 1 | 2014 | Multi-joint actuation platform for lower extremity soft exosuits · ICRA 2014 |
Human-robot interaction
physical human-robot interaction |
0.2 | 1 | 2014 | Multi-joint actuation platform for lower extremity soft exosuits · ICRA 2014 |
Accessibility and assistive technology › locomotion assistance
gait assistance |
0.2 | 1 | 2013 | A lightweight soft exosuit for gait assistance · ICRA 2013 |
Human-robot interaction
wearable robot |
0.2 | 1 | 2013 | A lightweight soft exosuit for gait assistance · ICRA 2013 |
Accessibility and assistive technology
assistive technology |
0.0 | 1 | 2013 | A lightweight soft exosuit for gait assistance · ICRA 2013 |
Methods — techniques the papers use, named apart from their topics
real-time admittance control · 0.2bowden cable transmission · 0.2pneumatic actuation · 0.2mckibben actuator · 0.2
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2014 | Multi-joint actuation platform for lower extremity soft exosuitsabstractLower-limb wearable robots have been proposed as a means to augment or assist the wearer's natural performance, in particular, in the military and medical field. Previous research studies on human-robot interaction and biomechanics have largely been performed with rigid exoskeletons that add significant inertia to the lower extremities and provide constraints to the wearer's natural kinematics in both actuated and non-actuated degrees of freedom. Actuated lightweight soft exosuits minimize these effects and provide a unique opportunity to study human-robot interaction in wearable systems without affecting the subjects underlying natural dynamics. In this paper, we present the design and control of a reconfigurable multi-joint actuation platform that can provide biologically realistic torques to ankle, knee, and hip joints through lower extremity soft exosuits. Two different soft exosuits have been designed to deliver assistive forces through Bowden cable transmission to the ankle and hip joints. Through human subject experiments, it is demonstrated that with a real-time admittance controller, accurate force profile tracking can be achieved during walking. The average energy delivered to the test subject was calculated while walking at 1.25 m/s and actuated with 15% of the total torque required by the biological joints. The results show that the ankle joint received an average of 3.02J during plantar flexion and that the hip joint received 1.67J during flexion each gait cycle. The efficiency of the described suit and controller in transferring energy to the human biological joints is 70% for the ankle and 48% for the hip. Ignacio Galiana, Alan T. Asbeck, Brendan Quinlivan, Stefano Marco Maria De Rossi, Conor J. Walsh |
ICRA | 4 |
| 2013 | A lightweight soft exosuit for gait assistanceabstractIn this paper we present a soft lower-extremity robotic exosuit intended to augment normal muscle function in healthy individuals. Compared to previous exoskeletons, the device is ultra-lightweight, resulting in low mechanical impedance and inertia. The exosuit has custom McKibben style pneumatic actuators that can assist the hip, knee and ankle. The actuators attach to the exosuit through a network of soft, inextensible webbing triangulated to attachment points utilizing a novel approach we call the virtual anchor technique. This approach is designed to transfer forces to locations on the body that can best accept load. Pneumatic actuation was chosen for this initial prototype because the McKibben actuators are soft and can be easily driven by an off-board compressor. The exosuit itself (human interface and actuators) had a mass of 3500 g and with peripherals (excluding air supply) is 7144 g. In order to examine the exosuit's performance, a pilot study with one subject was performed which investigated the effect of the ankle plantar-flexion timing on the wearer's hip, knee and ankle joint kinematics and metabolic power when walking. Wearing the suit in a passive unpowered mode had little effect on hip, knee and ankle joint kinematics as compared to baseline walking when not wearing the suit. Engaging the actuators at the ankles at 30% of the gait cycle for 250 ms altered joint kinematics the least and also minimized metabolic power. The subject's average metabolic power was 386.7 W, almost identical to the average power when wearing no suit (381.8 W), and substantially less than walking with the unpowered suit (430.6 W). This preliminary work demonstrates that the exosuit can comfortably transmit joint torques to the user while not restricting mobility and that with further optimization, has the potential to reduce the wearer's metabolic cost during walking. Michael F. Wehner, Brendan Quinlivan, Patrick M. Aubin, Ernesto Martinez-Villalpando, Michael Baumann 0008, Leia A. Stirling 0001, Kenneth G. Holt, Robert J. Wood, Conor J. Walsh |
ICRA | 2 |