Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Ching-Mei Chen

dblp:148/6919 · DBLP profile ↗
← Back
6ranked-venue papers
3as first author
0since 2021 · last 2020
0000-0002-3432-2388ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 5 · 3 first-authorArtificial intelligence and machine learning · 1Systems, architecture and hardware · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
1 paper
Robot manipulation · 70% Robot navigation and mapping · 30%

Topics — the 4 heaviest of 4, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Robot manipulation › robotic hand
compliant robotic hand
0.212014
Blind collision detection and obstacle characterisation using a compliant robotic arm · ICRA 2014
Robotics › Robot navigation and mapping
environment mapping
0.212014
Blind collision detection and obstacle characterisation using a compliant robotic arm · ICRA 2014
Robotics › Robot manipulation
grasping
0.212014
Blind collision detection and obstacle characterisation using a compliant robotic arm · ICRA 2014
Robotics › Robot manipulation › grasping
underactuated finger
0.112014
Blind collision detection and obstacle characterisation using a compliant robotic arm · ICRA 2014

Methods — techniques the papers use, named apart from their topics

vibration signal classification · 0.2machine learning · 0.2accelerometer-based collision detection · 0.2
YearPublicationVenuePosition
2020 Towards Wearable and Flexible Sensors and Circuits Integration for Stress Monitoring
abstract
Excessive stress is one of the main causes of mental illness. Long-term exposure of stress could affect one's physiological wellbeing (such as hypertension) and psychological condition (such as depression). Multisensory information such as heart rate variability (HRV) and pH can provide suitable information about mental and physical stress. This paper proposes a novel approach for stress condition monitoring using disposable flexible sensors. By integrating flexible amplifiers with a commercially available flexible polyvinylidene difluoride (PVDF) mechanical deformation sensor and a pH-type chemical sensor, the proposed system can detect arterial pulses from the neck and pH levels from sweat located in the back of the body. The system uses organic thin film transistor (OTFT)-based signal amplification front-end circuits with modifications to accommodate the dynamic signal ranges obtained from the sensors. The OTFTs were manufactured on a low-cost flexible polyethylene naphthalate (PEN) substrate using a coater capable of Roll-to-Roll (R2R) deposition. The proposed system can capture physiological indicators with data interrogated by Near Field Communication (NFC). The device has been successfully tested with healthy subjects, demonstrating its feasibility for real-time stress monitoring.
Ching-Mei Chen, Salzitsa Anastasova-Ivanova, Bruno Miguel Gil Rosa, Benny P. L. Lo, Hazel Assender, Guang-Zhong Yang
IEEE J. Biomed. Health Informatics1
2019 Roll-to-Roll processable OTFT-based Amplifier and Application for pH sensing
abstract
The prospect of roll-to-roll (R2R) processable Organic Thin Film Transistors (OTFTs) and circuits has attracted attention due to their mechanical flexibility and low cost of manufacture. This work will present a flexible electronics application for pH sensing with flexible and wearable signal processing circuits. A transimpedance amplifier was designed and fabricated on a polyethylene naphthalate (PEN) substrate prototype sheet that consists of 54 transistors. Different types and current ratios of current mirrors were initially created and then a suitable simple 1:3 current mirror (200nA) was selected to present the best performance of the proposed OTFT based transimpedance amplifier (TIA). Finally, this transimpedance amplifier was connected to a customized needle-based pH sensor that was induced as microfluidic collector for potential disease diagnosis and healthcare monitoring.
Ching-Mei Chen, Salzitsa Anastasova-Ivanova, Bruno Miguel Gil Rosa, Benny P. L. Lo, Hazel Assender
BSN2
2016 Wireless wearable self-calibrated sensor for perfusion assessment of myocutaneous tissue
abstract
Blood flow and perfusion monitoring are critical appraisal to ensure survival of tissue flap after reconstructive surgery. Many techniques have been developed over the years: from optical to chemical, invasive or not, they all have limitations in their price, risks and adaptiveness to the patient. A wireless wearable self-calibrated device, based on near infrared spectroscopy (NIRS) was developed for blood flow and perfusion monitoring contingent on tissue oxygen saturation (StO2). The use of such device is particularly relevant in the case of free flap myocutaneous reconstructive surgery; postoperative monitoring of the flap is crucial for a prompt intervention in case of thrombosis. Although failure rate is low, the rate of additional surgery following anastomosis problem is about 50%. NIRS has shown promising results for the monitoring of free flap, however lack of adaptation to its environment (ambient light) and users (body mass index (BMI), skin tone, alcohol and smoking habits or physical activity level) hinders the practical use of this technique. To overcome those limitations, a self-calibrated approach is introduced. Tested with is chaemia and cold water experiments on healthy subjects of different skin tones, its ability to personalize its calibration is demonstrated. Furthermore, using a vascular phantom, it is also able to detect pulses, differentiate venous and arterial coloured-like fluids with distinct clusters and detect significant changes in simulated partial venous occlusion. Placed in the trained classifier, partial occlusion data showed similar results between predicted and true classification. Further analysis from partial occlusion data showed that distinct clusters for 75% and 100% occlusion emerged.
Melissa Berthelot, Ching-Mei Chen, Guang-Zhong Yang, Benny P. L. Lo
BSN2
2015 A multi-sensor platform for monitoring diabetic peripheral neuropathy
abstract
This paper proposes a novel concept of using a multiple PPG and ECG based sensing platform aimed for monitoring the progress of diabetic peripheral neuropathy (DPN). It explores the use of PPG sensor to capture pulse arrival time (PAT). Based on the same principal of using Brachial-ankle pulse wave velocity (baPWV) to assess DPN, this paper proposes a platform which integrated two PPG sensors and one 2-lead ECG sensor to detect the difference in PAT (pulse arrive time on the finger compare to the time when the pulse reaches the ankle) as a surrogate measure for evaluating the progression of DPN. Preliminary results show that PAT increases when a pressure was applied onto upper leg using a blood pressure cuff simulating arterial stiffness/DPN. It shows that PDN can potentially be quantified by measuring PAT by using the proposed platform.
Ching-Mei Chen, Kosy Onyenso, Guang-Zhong Yang, Benny P. L. Lo
BSN1
2014 Wearable Tissue Oxygenation Monitoring Sensor and a Forearm Vascular Phantom Design for Data Validation
abstract
Photoplethysmography (PPG) is a well established method of measuring Heart Rate Variability (HRV) and blood oxygen saturation (SpO2) at the fingers, forehead or other areas of the body where pulsatile flow is present. However, obtaining reliable tissue oxygen saturation (StO2) from optical devices is more challenging due to a number of factors including motion and signal-to-noise ratio. Instrumentation of such devices as miniaturised wearable platforms would allow the device to be worn freely by patients in hospitals or at home. The purposes of this paper are to present: 1) a bespoke, low power StO2 sensor, 2) preliminary comparison to a commercially available photospectroscopy and laser Doppler machine (Oxygen 2 See, Medizintechnik, LEA, Germany) using a pressure cuff forearm ischaemia model, and 3) validation of fluid (blood) flow/relative haemoglobin measurements using a novel forearm phantom.
Ching-Mei Chen, Richard Kwasnicki, Benny P. L. Lo, Guang-Zhong Yang
BSN1
2014 Blind collision detection and obstacle characterisation using a compliant robotic arm
abstract
This paper presents a novel blind collision detection and material characterisation scheme for a compliant robotic arm. By the incorporation of a simple MEMS accelerometer at each joint, the robot is able to detect collision, identify the material of an obstacle, and create a map of the environment. Detailed hardware design is provided, illustrating its value for building a compact and economical robot platform. The proposed method does not require the additional use of vision sensor for mapping the environment, and hence is termed as `blind' collision detection and environment mapping. Based on the shock wave and vibration signals, the proposed algorithm is able to classify a range of materials encountered. Detailed laboratory evaluation was performed with controlled obstacle collision from different orientation and locations with varying force and materials. The proposed method has achieved 98% detection sensitivity while maintaining 77% specificity. Furthermore, by using sound feature extraction and machine learning techniques, the classifier produces an accuracy of 98% for classifying four different impact materials. In this paper, we also demonstrate its use for detailed environment mapping by using the proposed method.
Piyamate Wisanuvej, Ching-Mei Chen, Guang-Zhong Yang
ICRA3