Demo Data from SIGIR 2026 / reviewers in the wild / expert
Gary H. Glover
dblp:15/3741 · also Gary Glover
· DBLP profile ↗
5ranked-venue papers
0as first author
0since 2021 · last 2018
0000-0002-0562-0474ORCID · verified
Domains — the database's venue-derived domains; a paper can count in several
Applied, interdisciplinary, general and emerging computing · 3Graphics, computer vision, multimedia, augmented reality and games · 2
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Interdisciplinary, comprehensive, and emerging computing
1 paper |
Medical and health informatics · 100% | |
| Computer graphics and multimedia
2 papers |
Image and video processing · 86% Computational photography and imaging · 14% |
Topics — the 5 heaviest of 5, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Image and video processing
image reconstruction |
0.1 | 2 | 2006 | A generalization of the two-dimensional prolate spheroidal wave function method for nonrectilinear MRI data acquisition methods · IEEE Trans. Image Process. 2006 Phase unwrapping of MR phase images using Poisson equation · IEEE Trans. Image Process. 1995 |
Medical and health informatics › neuroimaging
functional magnetic resonance imaging |
0.1 | 1 | 2006 | A generalization of the two-dimensional prolate spheroidal wave function method for nonrectilinear MRI data acquisition methods · IEEE Trans. Image Process. 2006 |
Medical and health informatics › medical imaging
magnetic resonance imaging |
0.1 | 1 | 2006 | A generalization of the two-dimensional prolate spheroidal wave function method for nonrectilinear MRI data acquisition methods · IEEE Trans. Image Process. 2006 |
Computational photography and imaging
magnetic resonance imaging |
0.0 | 1 | 1995 | Phase unwrapping of MR phase images using Poisson equation · IEEE Trans. Image Process. 1995 |
Image and video processing › image restoration › inverse problem › signal reconstruction
phase unwrapping |
0.0 | 1 | 1995 | Phase unwrapping of MR phase images using Poisson equation · IEEE Trans. Image Process. 1995 |
Methods — techniques the papers use, named apart from their topics
spiral trajectory · 0.1prolate spheroidal wave function method · 0.1poisson equation · 0.0least squares · 0.0fast poisson solver · 0.0
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2018 | MR Performance in the Presence of a Radio Frequency-Penetrable Positron Emission Tomography (PET) Insert for Simultaneous PET/MRIabstractDespite the great promise of integrated positron emission tomography (PET)/magnetic resonance (MR) imaging to add molecular information to anatomical and functional MR, its potential impact in medicine is diminished by a very high cost, limiting its dissemination. An RF-penetrable PET ring that can be inserted into any existing MR system has been developed to address this issue. Employing optical signal transmission along with battery power enables the PET ring insert to electrically float with respect to the MR system. Then, inter-modular gaps of the PET ring allow the RF transmit field from the standard built-in body coil to penetrate into the PET fields-of-view (FOV) with some attenuation that can be compensated for. MR performance, including RF noise, magnetic susceptibility, RF penetrability through and $B_{1}$ uniformity within the PET insert, and MR image quality, were analyzed with and without the PET ring present. The simulated and experimentally measured RF field attenuation factors with the PET ring present were -2.7 and -3.2 dB, respectively. The magnetic susceptibility effect (0.063 ppm) and noise emitted from the PET ring in the MR receive channel were insignificant. $B_{1}$ homogeneity of a spherical agar phantom within the PET ring FOV dropped by 8.4% and MR image SNR was reduced by 3.5 and 4.3 dB with the PET present for gradient-recalled echo and fast-spin echo, respectively. This paper demonstrates, for the first time, an RF-penetrable PET insert comprising a full ring of operating detectors that achieves simultaneous PET/MR using the standard built-in body coil as the RF transmitter. Brian J. Lee, Alexander M. Grant, Chen-Ming Chang, Ronald D. Watkins, Gary H. Glover, Craig S. Levin |
IEEE Trans. Medical Imaging | 5 |
| 2006 | A generalization of the two-dimensional prolate spheroidal wave function method for nonrectilinear MRI data acquisition methodsabstractThe two-dimensional (2-D) prolate spheroidal wave function (2-D PSWF) method was previously introduced as an efficient method for trading off between spatial and temporal resolution in magnetic resonance imaging (MRI), with minimal penalty due to truncation and partial volume effects. In the 2-D PSWF method, the k-space sampling area and a matching 2-D PSWF filter, with optimal signal concentration and minimal truncation artifacts, are determined by the shape and size of a given convex region of interest (ROI). The spatial information in the reduced k-space data is used to calculate the total image intensity over a nonsquare ROI instead of producing a low-resolution image. This method can be used for tracking dynamic signals from non-square ROIs using a reduced k-space sampling area, while achieving minimal signal leakage. However, the previous theory is limited to the case of rectilinear sampling. In order to make the 2-D PSWF method more suitable for dynamic studies, this paper presents a generalized version of the 2-D PSWF theory that can be applied to nonrectilinear data acquisition methods. The method is applied to an fMRI study using a spiral trajectory, which illustrates the methods efficiency at tracking hemodynamic signals with high temporal resolution. Martin A. Lindquist, Cun-Hui Zhang, Gary H. Glover, Larry A. Shepp, Qing X. Yang |
IEEE Trans. Image Process. | 3 |
| 2003 | Fast Algorithms for GS Model-Based Image Reconstruction in Data-Sharing Fourier ImagingabstractMany imaging experiments involve acquiring a time series of images. To improve imaging speed, several "data-sharing" methods have been proposed, which collect one (or a few) high-resolution reference(s) and a sequence of reduced data sets. In image reconstruction, two methods, known as "Keyhole" and reduced-encoding imaging by generalized-series reconstruction (RIGR), have been used. Keyhole fills in the unmeasured high-frequency data simply with those from the reference data set(s), whereas RIGR recovers the unmeasured data using a generalized series (GS) model, of which the basis functions are constructed based on the reference image(s). This correspondence presents a fast algorithm (and two extensions) for GS-based image reconstruction. The proposed algorithms have the same computational complexity as the Keyhole algorithm, but are more capable of capturing high-resolution dynamic signal changes. Zhi-Pei Liang, Bruno Madore, Gary H. Glover, Norbert J. Pelc |
IEEE Trans. Medical Imaging | 3 |
| 1995 | Phase unwrapping of MR phase images using Poisson equationabstractThe authors have developed a technique based on a solution of the Poisson equation to unwrap the phase in magnetic resonance (MR) phase images. The method is based on the assumption that the magnitude of the inter-pixel phase change is less than pi per pixel. Therefore, the authors obtain an estimate of the phase gradient by "wrapping" the gradient of the original phase image. The problem is then to obtain the absolute phase given the estimate of the phase gradient. The least-squares (LS) solution to this problem is shown to be a solution of the Poisson equation allowing the use of fast Poisson solvers. The absolute phase is then obtained by mapping the LS phase to the nearest multiple of 2 K from the measured phase. The proposed technique is evaluated using MR phase images and is proven to be robust in the presence of noise. An application of the proposed method to the 3-point Dixon technique for water and fat separation is demonstrated. Samuel Moon-Ho Song, Sandy Napel, Norbert J. Pelc, Gary H. Glover |
IEEE Trans. Image Process. | 4 |
| 1993 | MR susceptibility misregistration correctionabstractThe authors present a new in vivo method to correct the nonlinear, object-shape-dependent and material-dependent spatial distortion in magnetic resonance (MR) images caused by magnetic susceptibility variations. This distortion across the air/tissue interface before and after the correction is quantified using a phantom. The results are compared to the distortion-free computed tomography (CT) images of the same phantom by fusing CT and MR images using fiducials, with a registration accuracy of better than a millimeter. The distortion at the bone/tissue boundary is negligible compared to the typical MRI (MR imaging) resolution of 1 mm, while that at the air/tissue boundary creates displacements of about 2 mm (for G(x) 3.13 mT/m). This is a significant value if MRI is to provide highly accurate geometric measurements, as in the case of target localization for stereotaxic surgery. The correction scheme provides MR images with accuracy similar to that of CT: 1 mm. A new method to estimate the magnetic susceptibility of materials from MR images is presented. The magnetic susceptibility of cortical bone is measured using a SQUID magnetometer, and is found to be -8.86 ppm (with respect to air), which is quite similar to that of tissue (-9 ppm). Thilaka S. Sumanaweera, Gary H. Glover, Thomas O. Binford, John R. Adler Jr. |
IEEE Trans. Medical Imaging | 2 |