Demo Data from SIGIR 2026 / reviewers in the wild / expert
P. Artrit
dblp:15/3857
· DBLP profile ↗
1ranked-venue papers
0as first author
0since 2021 · last 2002
—ORCID · none
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 1Systems, architecture and hardware · 1
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Computer architecture, parallel and distributed computing, and storage systems
1 paper |
Embedded and real-time systems · 100% | |
| Artificial intelligence
1 paper |
Robot manipulation · 100% |
Topics — the 3 heaviest of 3, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Embedded and real-time systems
pneumatic artificial muscle |
0.0 | 1 | 2002 | Enhanced Dynamic Performance in Pneumatic Muscle Actuators · ICRA 2002 |
Robotics › Robot manipulation › actuation › pneumatic artificial muscle
mckibben actuator |
0.0 | 1 | 2002 | Enhanced Dynamic Performance in Pneumatic Muscle Actuators · ICRA 2002 |
Robotics › Robot manipulation
soft robotics |
0.0 | 1 | 2002 | Enhanced Dynamic Performance in Pneumatic Muscle Actuators · ICRA 2002 |
Methods — techniques the papers use, named apart from their topics
filler material insertion · 0.1airflow optimization · 0.1
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2002 | Enhanced Dynamic Performance in Pneumatic Muscle ActuatorsabstractPneumatic muscle actuators based on McKibben muscles have performance characteristics that may be of considerable significance in robotics due to their power/weight ratio and use as user friendly soft drives. However, the dynamic response (bandwidth) has been inferior to electric systems, with a secondary concern over system stiffness. In this paper, the bandwidth limit is addressed from two perspectives; air flow effects and the physical structure of the actuator. It is shown that by reducing the dead volume within the muscle structure (by the addition of a variety of filler materials) the bandwidth can be increased by up to 400%, with similar increases in system stiffness. At the same time the air volume used to power the actuator can be reduced by up to 80-90%. The methods of achieving these improvements are fully assessed. Also, by ensuring effective air flow rates, it is shown that bandwidth limits can be increased by several 100% and potentially increases of 1000s% are possible. Steve Davis 0001, J. Canderle, P. Artrit, Nikolaos G. Tsagarakis, Darwin G. Caldwell |
ICRA | 3 |