Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Ellen Feldman

dblp:151/9651 · DBLP profile ↗
← Back
1ranked-venue papers
0as first author
0since 2021 · last 2014
0000-0001-5263-0598ORCID · reported

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 1Systems, architecture and hardware · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
1 paper
Robot manipulation · 100%
Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%

Topics — the 3 heaviest of 3, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Robot manipulation
force sensing
0.212014
Towards robot-assisted vitreoretinal surgery: Force-sensing micro-forceps integrated with a handheld micromanipulator · ICRA 2014
Medical and health informatics › surgical robotics
robot-assisted surgery
0.112014
Towards robot-assisted vitreoretinal surgery: Force-sensing micro-forceps integrated with a handheld micromanipulator · ICRA 2014
Medical and health informatics › ophthalmology
vitreoretinal surgery
0.112014
Towards robot-assisted vitreoretinal surgery: Force-sensing micro-forceps integrated with a handheld micromanipulator · ICRA 2014

Methods — techniques the papers use, named apart from their topics

tremor cancellation · 0.4force sensing · 0.4
YearPublicationVenuePosition
2014 Towards robot-assisted vitreoretinal surgery: Force-sensing micro-forceps integrated with a handheld micromanipulator
abstract
In vitreoretinal practice, controlled tremor-free motion and limitation of applied forces to the retina are two highly desired features. This study addresses both requirements with a new integrated system: a force-sensing motorized micro-forceps combined with an active tremor-canceling handheld micromanipulator, known as Micron. The micro-forceps is a 20 Ga instrument that is mechanically decoupled from its handle and senses the transverse forces at its tip with an accuracy of 0.3 mN. Membrane peeling trials on a bandage phantom revealed a 60-95% reduction in the 2-20 Hz band in both the tip force and position spectra, while peeling forces remained below the set safety threshold.
Berk Gonenc, Ellen Feldman, Peter Gehlbach, James Handa, Russell H. Taylor, Iulian Iordachita
ICRA2