Demo Data from SIGIR 2026 / reviewers in the wild / expert
Simon H. Sündermann
dblp:152/3949 · also Simon Harald Sündermann
· DBLP profile ↗
2ranked-venue papers
0as first author
1since 2021 · last 2022
—ORCID · none
Domains — the database's venue-derived domains; a paper can count in several
Graphics, computer vision, multimedia, augmented reality and games · 2 · 1 since 2021
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Computer graphics and multimedia
1 paper |
Visualization and visual analytics · 100% | |
| Interdisciplinary, comprehensive, and emerging computing
1 paper |
Medical and health informatics · 100% |
Topics — the 2 heaviest of 2, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Visualization and visual analytics
medical visualization |
0.2 | 1 | 2014 | Stent Maps - Comparative Visualization for the Prediction of Adverse Events of Transcatheter Aortic Valve Implantations · IEEE Trans. Vis. Comput. Graph. 2014 |
Medical and health informatics
transcatheter aortic valve implantation |
0.1 | 1 | 2014 | Stent Maps - Comparative Visualization for the Prediction of Adverse Events of Transcatheter Aortic Valve Implantations · IEEE Trans. Vis. Comput. Graph. 2014 |
Methods — techniques the papers use, named apart from their topics
mechanical simulation · 0.4heatmap visualization · 0.4
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2022 | Using Position-Based Dynamics for Simulating Mitral Valve Closure and Repair ProceduresabstractAbstract To achieve the best treatment of mitral valve disease in a patient, surgeons aim to optimally combine complementary surgical techniques. Image‐based in silico simulation as well as visualization of the mitral valve dynamics can support the visual analysis of the patient‐specific valvular dynamics and enable an exploration of different therapy options. The usage in a time‐constrained clinical environment requires a mitral valve model that is cost‐effective, easy to set up, parameterize and evaluate. Working towards this goal, we develop a simplified model of the mitral valve and analyse its applicability for the sketched use‐case. We propose a novel approach to simulate the mitral valve with position‐based dynamics. The resulting mitral valve model can be deformed to simulate the closing and opening, and incorporate changes caused by virtual interventions in the simulation. Ten mitral valves were reconstructed from transesophageal echocardiogram sequences of patients with normal and abnormal physiology for evaluation. Simulation results showed good agreements with expert annotations of the original image data and reproduced valve closure in all cases. In four of five pathological cases, abnormal closing behaviour was correctly reproduced. In future research, we aim to improve the parameterization of the model in terms of biomechanical correctness and perform a more extensive validation. Lars Walczak, Joachim Georgii, Lennart Tautz, Mathias Neugebauer, Isaac Wamala, Simon H. Sündermann, Volkmar Falk, Anja Hennemuth |
Comput. Graph. Forum | 6 |
| 2014 | Stent Maps - Comparative Visualization for the Prediction of Adverse Events of Transcatheter Aortic Valve ImplantationsabstractTranscatheter aortic valve implantation (TAVI) is a minimally-invasive method for the treatment of aortic valve stenosis in patients with high surgical risk. Despite the success of TAVI, side effects such as paravalvular leakages can occur postoperatively. The goal of this project is to quantitatively analyze the co-occurrence of this complication and several potential risk factors such as stent shape after implantation, implantation height, amount and distribution of calcifications, and contact forces between stent and surrounding structure. In this paper, we present a two-dimensional visualization (stent maps), which allows (1) to comprehensively display all these aspects from CT data and mechanical simulation results and (2) to compare different datasets to identify patterns that are typical for adverse effects. The area of a stent map represents the surface area of the implanted stent - virtually straightened and uncoiled. Several properties of interest, like radial forces or stent compression, are displayed in this stent map in a heatmap-like fashion. Important anatomical landmarks and calcifications are plotted to show their spatial relation to the stent and possible correlations with the color-coded parameters. To provide comparability, the maps of different patient datasets are spatially adjusted according to a corresponding anatomical landmark. Also, stent maps summarizing the characteristics of different populations (e.g. with or without side effects) can be generated. Up to this point several interesting patterns have been observed with our technique, which remained hidden when examining the raw CT data or 3D visualizations of the same data. One example are obvious radial force maxima between the right and non-coronary valve leaflet occurring mainly in cases without leakages. These observations confirm the usefulness of our approach and give starting points for new hypotheses and further analyses. Because of its reduced dimensionality, the stent map data is an appropriate input for statistical group evaluation and machine learning methods. Silvia Born, Simon H. Sündermann, Christoph Russ, Raoul Hopf, Carlos E. Ruiz, Volkmar Falk, Michael Gessat |
IEEE Trans. Vis. Comput. Graph. | 2 |