Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Michael W. Perry

dblp:167/8528 · DBLP profile ↗
← Back
2ranked-venue papers
2as first author
0since 2021 · last 1984
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Computer networks · 2 · 2 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Computer networks
2 papers
Optical networks · 50% Physical-layer communications · 25% Network management and operations · 25%

Topics — the 3 heaviest of 3, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Optical networks
submarine optical systems
0.021984
Physical Design of the SL Branching Repeater · IEEE J. Sel. Areas Commun. 1984
Physical Design of the SL Repeater · IEEE J. Sel. Areas Commun. 1984
Network management and operations
failure recovery
0.011984
Physical Design of the SL Branching Repeater · IEEE J. Sel. Areas Commun. 1984
Physical-layer communications › relaying › relay systems
repeater
0.011984
Physical Design of the SL Repeater · IEEE J. Sel. Areas Commun. 1984

Methods — techniques the papers use, named apart from their topics

thermal analysis · 0.0physical design · 0.0
YearPublicationVenuePosition
1984 Physical Design of the SL Repeater
abstract
SL undersea fiber-optic cable allows for the installation of multiple pairs of fibers in the same cable. Using the same high-pressure repeater housing as used in previous undersea systems (and thereby accruing the benefits of no tooling costs and proven handling methods), we are able to mount six optical regenerators. This group of regenerators will dissipate approximately 30 W in service. Previous undersea repeaters dissipated approximately 8 W and achieved a maximum internal temperature of 5° C above the repeater ambient. That might imply a temperature of 20° C above ambient for the SL repeater, which would be intolerably high for reliable undersea performance and longevity. The main thrust of the SL design was to lower this temperature rise. We have achieved a design which is capable of dissipating 30 W with only 4°C temperature rise. This paper describes the design steps necessary to achieve this result and examines the overall repeater structure showing its special design features for accommodating fiber sealing and jointing.
Michael W. Perry, Gordon A. Reinold, Paul A. Yeisley
IEEE J. Sel. Areas Commun.1
1984 Physical Design of the SL Branching Repeater
abstract
Since undersea fiber-optic cable can carry multiple transmission paths, it is now possible to conceive of a device which allows physical separation of the fiber paths and the subsequent routing of these paths to different landing points. This paper describes such a device now being designed for TAT 8. It has the capability of switching power from shore such that in the case of branch failure (such as might be caused by surface activities like fishing, etc.) the service in the other branch can be maintained. It also can have the capability of switching the incoming transoceanic signal paths to either shore-end cable so that all transoceanic capability can be maintained in the face of such failure.
Michael W. Perry, Gordon A. Reinold, Paul A. Yeisley
IEEE J. Sel. Areas Commun.1