Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Yanggang Feng

dblp:185/9271 · DBLP profile ↗
← Back
4ranked-venue papers
2as first author
3since 2021 · last 2025
0000-0001-6161-3394ORCID · verified

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 2 · 2 since 2021Systems, architecture and hardware · 2 · 2 since 2021Applied, interdisciplinary, general and emerging computing · 2 · 2 first-author · 1 since 2021

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Human-computer interaction and pervasive computing
2 papers
Health and well-being technologies · 59% Accessibility and assistive technology · 26% Human-robot interaction · 15%

Topics — the 3 heaviest of 4, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Health and well-being technologies › rehabilitation technology
rehabilitation robotics
0.912025
A Wearable Isokinetic Training Robot for Enhanced Bedside Knee Rehabilitation · IEEE Trans. Robotics 2025
Accessibility and assistive technology › assistive technology
robotic prosthesis
0.412020
Energy Regeneration From Electromagnetic Induction by Human Dynamics for Lower Extremity Robotic Prostheses · IEEE Trans. Robotics 2020
Human-robot interaction
wearable robot
0.312025
A Wearable Isokinetic Training Robot for Enhanced Bedside Knee Rehabilitation · IEEE Trans. Robotics 2025

Methods — techniques the papers use, named apart from their topics

variable stiffness actuation · 0.9energy regeneration · 0.9electromagnetic induction · 0.4
YearPublicationVenuePosition
2025 A Wearable Isokinetic Training Robot for Enhanced Bedside Knee Rehabilitation
abstract
Knee pain is prevalent in over 20% of the population, limiting the mobility of those affected. In turn, isokinetic dynamometers and robots have been used to facilitate rehabilitation for those still capable of ambulation. However, there are at most only a few wearable robots capable of delivering isokinetic training for bedridden patients. Here, we developed a wearable robot that provides bedside isokinetic training by utilizing a variable stiffness actuator and dynamic energy regeneration. The efficacy of this device was validated in a study involving six subjects with debilitating knee injuries. During two courses of rehabilitation over a total of three weeks, the average peak torque, average torque, and average work produced by their affected knees increased significantly by 81.0%, 101.4%, and 117.6%, respectively. Furthermore, the device's energy regeneration features were found capable of extending its operating time to 198 days under normal usage, representing a 57.8% increase over the same device without regeneration. These results suggest potential methodologies for delivering isokinetic joint rehabilitation to bedridden patients in areas with limited infrastructure.
Yanggang Feng, Yuebing Li, Fuzhen Yuan, Yan Huang 0007, Qining Wang, Wuxiang Zhang, Xilun Ding
IEEE Trans. Robotics1
2024 Continuously Estimate and Control Prosthetic Grip Force by an Optical Waveguide Sensor
abstract
The emergence of intelligent prostheses has facilitated the life and work of disabled patients. The interaction aspect of prostheses has become a highlight research topic in the field of rehabilitation robotics. However, most of the existing prosthetic interaction methods focus on the use of myoelectricity to classify finite gestures, rather than continuous (infinite) force detection, which greatly limits the use of prosthetic scenarios. In this study, a novel optical waveguide sensor was used to collect muscle deformation information from the human arm for continuous control of the prosthetic grip force. The optical waveguide sensor was embedded with carbon fiber to limit the stretching of the waveguide, which led to the optical waveguide sensor being sensitive to bending deformation. Compared with EMGs, the accuracy of continuous grip force control based on the optical waveguide sensor is higher. The R-Square for prosthetic grip force and hand grip force were 0.867 and 0.9724 in the periodic and sustaining grip force experiments, respectively. The results suggested that the proposed method could provide a new approach to the interaction of prostheses.
Linhang Ju, Hanze Jia, Yanjun Shi, Xilun Ding, Yanggang Feng, Wuxiang Zhang
ICRA5
2024 A Series Variable-stiffness Joint for Robot-assisted Resistance Training
abstract
As the safe and comfortable human-robot interaction draw more attention, variable stiffness joints are adopted in the rehabilitation robots for the compliant experiences. For patients with joint injury, resistance training has demonstrated its efficacy in concurrently enhancing muscle strength in the rehabilitation process. Here, we introduce a compact passive joint with variable stiffness and damping generation capability for robot-assisted resistance training. The abilities of serial variable stiffness and passive angle tracking were demonstrated by a prototype. The variable stiffness mechanism was mainly formed by 3D-printing, which only weighs 0.1kg with a wide range of stiffness (0.004-11.176Nm/rad). Moreover, the torque-angular displacement characteristics show excellent linearity at high joint stiffness. Finally, the feasibility of being integrated into the wearable rehabilitation robot has been evaluated.
Yuebing Li, Wuxiang Zhang, Yanggang Feng
IROS5
2020 Energy Regeneration From Electromagnetic Induction by Human Dynamics for Lower Extremity Robotic Prostheses
abstract
Wearable robotic devices often need electrical energy. An interesting idea is to collect mechanical energy during walking and convert it into electrical energy to recharge these devices directly. In this article, we built a light-weight robotic prosthesis (1.3 kg) with the feature of self-charging. During stance phase, the prosthetic ankle joint with damping, is driven by human dynamics. The rotated ankle joint backdrives the motor, and the motor works as a generator according to the electromagnetic induction theory. Five subjects participated in experiments to verify the feasibility and five speeds walking were studied (0.7, 0.9, 1.1, and 1.3 m/s treadmill speeds and one self-selected outdoor walking speed). Experimental results demonstrate that the electrical regenerative energy per step is 1.53 ± 0.29 J on average. Meanwhile, an average consumed energy per step of the robotic prosthesis is 4.64 ± 0.15 J, which means 33 ± 5% energy can be returned to the active prosthesis (battery, 24 V, 2.6 Ah).
Yanggang Feng, Jingeng Mai, Sunil K. Agrawal, Qining Wang
IEEE Trans. Robotics1